5. (a) In a 120 V compound generator, the resistances of the armature, shunt and series winding are 0.06, 25, and 0.04 ohms respectively. The load current is 100 A at 120 V. Find the induced emf and the armature current when the machine is connected as (a) a long shunt and as (b) short shunt. (c) If a diverter of 0.102 is connected in parallel with the series field winding of (a) determine the current through the series field and in the diverter. Neglect brush drop and ignore armature reaction. (Ans. a. 104.8 amp, 130.48 volts, b. 104.96 Amp, 30.29 volts c. 74.857 amp, 29.94 amp

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter12: Power System Controls
Section: Chapter Questions
Problem 12.11P
icon
Related questions
Question

Alreadt answered, all need is the solution and formula. Thankss

5. (a) In a 120 V compound generator, the resistances of the armature, shunt and
series winding are 0.06, 25, and 0.04 ohms respectively. The load current is 100
A at 120 V. Find the induced emf and the armature current when the machine is
connected as (a) a long shunt and as (b) short shunt. (c) If a diverter of 0.102 is
connected in parallel with the series field winding of (a) determine the current
through the series field and in the diverter. Neglect brush drop and ignore armature
reaction.
(Ans. a. 104.8 amp, 130.48 volts, b. 104.96 Amp, 30.29 volts c. 74.857 amp, 29.94 amp
Transcribed Image Text:5. (a) In a 120 V compound generator, the resistances of the armature, shunt and series winding are 0.06, 25, and 0.04 ohms respectively. The load current is 100 A at 120 V. Find the induced emf and the armature current when the machine is connected as (a) a long shunt and as (b) short shunt. (c) If a diverter of 0.102 is connected in parallel with the series field winding of (a) determine the current through the series field and in the diverter. Neglect brush drop and ignore armature reaction. (Ans. a. 104.8 amp, 130.48 volts, b. 104.96 Amp, 30.29 volts c. 74.857 amp, 29.94 amp
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning