7. When it is necessary to provide automatic control of the voltage output at constant speed, the generator selected is a 8. The current through the shunt winding of a compound generator is not sufficient to the field poles. 9. The terminal voltage output of a cumulative compound-wound generator should as the load current is increased. 10. When the output voltage of a generator is the same at both no load and full load, the generator is called a(n) type. 11. Compound-wound generators are generally designed to be of the type. 12. The amount of compounding that can be obtained from a generator is controlled by

Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter18: Troubleshooting Modern Refrigeration, Heating, And Air-conditioning Control Circuitry And Systems
Section: Chapter Questions
Problem 7RQ
icon
Related questions
Question
100%

Select the correct answer for each of the following statements

Book Source: Electricity 3 | 10th Edition ISBN-13:9781111646738 ISBN:1111646732 Authors:Jeffrey J. Keljik

B. Select the correct answer to questions 7 through 12 from the following list, and place
it in the space provided.
a. field poles
b. diverter rheostat
c. compound-wound generator
d. saturate
j. overcompounding.
e. decrease
k. remain constant
f. shunt generator
1. undercompounding
7. When it is necessary to provide automatic control of the voltage output at constant
speed, the generator selected is a
8. The current through the shunt winding of a compound generator is not sufficient to
the field poles.
g. increase
h. flat compounding
į, shunt field rheostat
9. The terminal voltage output of a cumulative compound-wound generator should
as the load current is increased.
10. When the output voltage of a generator is the same at both no load and full load, the
generator is called a(n)
type.
11. Compound-wound generators are generally designed to be of the
type.
12. The amount of compounding that can be obtained from a generator is controlled by
Transcribed Image Text:B. Select the correct answer to questions 7 through 12 from the following list, and place it in the space provided. a. field poles b. diverter rheostat c. compound-wound generator d. saturate j. overcompounding. e. decrease k. remain constant f. shunt generator 1. undercompounding 7. When it is necessary to provide automatic control of the voltage output at constant speed, the generator selected is a 8. The current through the shunt winding of a compound generator is not sufficient to the field poles. g. increase h. flat compounding į, shunt field rheostat 9. The terminal voltage output of a cumulative compound-wound generator should as the load current is increased. 10. When the output voltage of a generator is the same at both no load and full load, the generator is called a(n) type. 11. Compound-wound generators are generally designed to be of the type. 12. The amount of compounding that can be obtained from a generator is controlled by
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
DC Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L