A 15-kVA, 2300/230- Question-2 !* V transformer has the following resistances and leakage reactances: R1 = 3 Q, R2= 0.0145 Q, X,= 4 Q, X2=0.0245 Q. The equivalent core-loss resistance and the magnetizing reactance on the primary side %3D of the transformer are 105 kQ and 11 kQ, respectively. The transformer is operating at full load, at the rated voltage at the load, and 0.8 power factor leading. ; Draw the approximate a)" equivalent circuit seen from secondary side (include all resistance and reactance values based on given data in the question). b) - - !Formulate and calculate the .. secondary winding current I2. c) / Determine the output power.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.13P: A single-phase 50-kVA,2400/240-volt,60-Hz distribution transformer has a 1-ohm equivalent leakage...
icon
Related questions
Question
A 15-kVA, 2300/230-
Question-2 (*
V transformer has the following
resistances and leakage reactances: R¡ = 3
Q, R2= 0.0145 Q, X,= 4 0, X2=0.0245 Q. The
equivalent core-loss resistance and the
%3D
magnetizing reactance on the primary side
of the transformer are 105 kQ and 11 kQ,
respectively. The transformer is operating
at full load, at the rated voltage at the load,
and 0.8 power factor leading.
a) .
; Draw the approximate
equivalent circuit seen from secondary
side (include all resistance and reactance
values based on given data in the
question).
Formulate and calculate the
b) i-
secondary winding current I2.
c)
:- Determine the output power.
d) (* :
Formulate and calculate the source
voltage referred to secondary V.
Transcribed Image Text:A 15-kVA, 2300/230- Question-2 (* V transformer has the following resistances and leakage reactances: R¡ = 3 Q, R2= 0.0145 Q, X,= 4 0, X2=0.0245 Q. The equivalent core-loss resistance and the %3D magnetizing reactance on the primary side of the transformer are 105 kQ and 11 kQ, respectively. The transformer is operating at full load, at the rated voltage at the load, and 0.8 power factor leading. a) . ; Draw the approximate equivalent circuit seen from secondary side (include all resistance and reactance values based on given data in the question). Formulate and calculate the b) i- secondary winding current I2. c) :- Determine the output power. d) (* : Formulate and calculate the source voltage referred to secondary V.
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L