A 460 mm x 510 mm rectangular concrete interior column is reinforced with ten - 19-mm-diameter bars. The column rest centrally on a 2 m x 3 m x 710 mm rectangular spread footing as shown in Figure 1. The design properties used are, for column: f’c = 21 MPa, fy = 276 MPa; for footing: f’c = 35 MPa, fy = 345 MPa, ys = 20.425 kN/m3, yc = 23.5 kN/m3, 75 mm clear cover, 25-mm- diameter and allowable soil pressure of 200 kPa. find the following: 1. What is the value of the column capacity Pu in kN? 2. What is the effective depth of footing as required by one-way shear or beam shear in the short direction in mm? 3. What is the effective depth of footing as required by one-way shear or beam shear in the long direction in mm?

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

A 460 mm x 510 mm rectangular concrete interior column is reinforced with ten - 19-mm-diameter
bars. The column rest centrally on a 2 m x 3 m x 710 mm rectangular spread footing as shown in
Figure 1. The design properties used are, for column: f’c = 21 MPa, fy = 276 MPa; for footing:
f’c = 35 MPa, fy = 345 MPa, ys = 20.425 kN/m3, yc = 23.5 kN/m3, 75 mm clear cover, 25-mm-
diameter and allowable soil pressure of 200 kPa.

find the following:

1. What is the value of the column capacity Pu in kN?

2. What is the effective depth of footing as required by one-way shear or beam shear in the
short direction in mm?

3. What is the effective depth of footing as required by one-way shear or beam shear in the
long direction in mm?

4. What is the governing effective depth of footing as required by two-way shear or punching
shear mm?

5. How many rebars are needed in the long direction of the footing as required by bending
moment based on the given “average effective depth”. Round off your answer to whole
number?

6. How many rebars are needed in the short direction of the footing as required by bending
moment based on the given “average effective depth”. Round off your answer to whole
number?

7. How many pieces of bars are distributed in the inner band and each of the outer band?
Use an average effective depth “d” of 610 mm.

Note: The equation of column capacity for tied column is:
Pu= (0.80) Ag [0.85 f'c (1-pg) + Pg fy]
where $ = 0.65
Figure 1
Pu
510 mm
3m
460 mm
1.25m
710 mm
2m
Transcribed Image Text:Note: The equation of column capacity for tied column is: Pu= (0.80) Ag [0.85 f'c (1-pg) + Pg fy] where $ = 0.65 Figure 1 Pu 510 mm 3m 460 mm 1.25m 710 mm 2m
Expert Solution
steps

Step by step

Solved in 4 steps with 2 images

Blurred answer
Knowledge Booster
Foundation plan layout
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning