A- A 3-ph, double circi 20 kV, km, 50 Hz has a configuration as shown in the figure below where each phase in the double circuit has a double bundle with a spacing of d cm between the two conductors in the bundle where d is the last two digits (from right) of your registration mumber (i.e for the student that has a registration number 202112396, d = 96). Each conductor in the bundle has a diameter of 0.135 ft and a geometric mean radius (Ds = 1.6 cm). Calculate: 1- Inductance per phase per km. 2- Total inductive reactance. 3- This T.L. is required to supply 240 MVA at 0.86 lag P.f. at 320 kV, assuming that this load is divided equally between these two circuits, find the voltage drop across this T.L (ignore capacitive effect in the calculation). 4- What may happen if we replace the location of a' and c' bundles. Discuss your answer. 5- Suggest a way to reduce the value of the inductance. Verify your suggestion. -8 m 00 3m 00 3m 00 8 m 11 m

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.18P: Let a series RLC network be connected to a source voltage V, drawing a current I. (a) In terms of...
icon
Related questions
Question

thats it 

A- A 3-ph, double circuit O.H.T.L, 320 kV, 340 km, 50 Hz has a configuration as shown in the figure
below where each phase in the double circuit has a double bundle with a spacing of d cm between
the two conductors in the bundle where d is the last two digits (from right) of your registration
number (i.e for the student that has a registration mumber 202112396, d= 96).
Each conductor in the bundle has a diameter of 0.135 ft and a geometric mean radius (Ds = 1.6
cm). Calculate:
1- Inductance per phase per km.
2- Total inductive reactance.
3- This T.L. is required to supply 240 MVA at 0.86 lag P.f. at 320 kV, assuming that this load is
divided equally between these two circuits, find the voltage drop across this T.L (ignore
capacitive effect in the calculation).
4- What may happen if we replace the location of a' and c' bundles. Discuss your answer.
5- Suggest a way to ređuce the value of the inductance. Verify your suggestion.
-8 m
3m
3m
8 m
11 m
Transcribed Image Text:A- A 3-ph, double circuit O.H.T.L, 320 kV, 340 km, 50 Hz has a configuration as shown in the figure below where each phase in the double circuit has a double bundle with a spacing of d cm between the two conductors in the bundle where d is the last two digits (from right) of your registration number (i.e for the student that has a registration mumber 202112396, d= 96). Each conductor in the bundle has a diameter of 0.135 ft and a geometric mean radius (Ds = 1.6 cm). Calculate: 1- Inductance per phase per km. 2- Total inductive reactance. 3- This T.L. is required to supply 240 MVA at 0.86 lag P.f. at 320 kV, assuming that this load is divided equally between these two circuits, find the voltage drop across this T.L (ignore capacitive effect in the calculation). 4- What may happen if we replace the location of a' and c' bundles. Discuss your answer. 5- Suggest a way to ređuce the value of the inductance. Verify your suggestion. -8 m 3m 3m 8 m 11 m
Expert Solution
steps

Step by step

Solved in 6 steps with 1 images

Blurred answer
Knowledge Booster
Thermocouple
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning