A counterflow, concentric tube heat exchanger is designed to heat water from 34 to 80 deg C using hot oil,which is supplied to the annulus at 174 deg C and discharged at 140 deg C. The thin-walled inner tube has a diameter of Di=34 mm and the overall heat transfer coefficient is 500 W/m2. K. The design condition calls for a total heat transfer rate of 4400 W. What is the length of the heat exchanger? Select one: a. 0.82485 b. 1.0478 c. 0.95849 d. 0.7013

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter10: Heat Exchangers
Section: Chapter Questions
Problem 10.6P: Mot water is used to heat air in a double-pipe heat exchanger as shown in the following sketch. If...
icon
Related questions
Question
100%
A counterflow, concentric tube heat exchanger is designed to heat water from 34 to 80 deg C using hot oil,which is supplied to the annulus at 174 deg C and discharged at 140 deg C. The thin-walled inner tube has a diameter of Di=34 mm and the overall heat transfer coefficient is 500 W/m2. K. The design condition calls for a total heat transfer rate of 4400 W. What is the length of the heat exchanger? Select one: a. 0.82485 b. 1.0478 c. 0.95849 d. 0.7013
A counterflow, concentric tube heat exchanger
is designed to heat water from 34 to 80 deg C
using hot oil,which is supplied to the annulus
at 174 deg C and discharged at 140 deg C. The
thin-walled inner tube has a diameter of Di=34
mm and the overall heat transfer coefficient is
500 W/m2. K. The design condition calls for a
total heat transfer rate of 4400 W. What is the
length of the heat exchanger?
Select one:
a. 0.82485
b. 1.0478
c. 0.95849
d. 0.7013
Transcribed Image Text:A counterflow, concentric tube heat exchanger is designed to heat water from 34 to 80 deg C using hot oil,which is supplied to the annulus at 174 deg C and discharged at 140 deg C. The thin-walled inner tube has a diameter of Di=34 mm and the overall heat transfer coefficient is 500 W/m2. K. The design condition calls for a total heat transfer rate of 4400 W. What is the length of the heat exchanger? Select one: a. 0.82485 b. 1.0478 c. 0.95849 d. 0.7013
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Heat Exchangers
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning