(c) i) Calculate the tube-side convective heat transfer coefficient (h) if the heat exchanger has 508 tubes of 20 mm outside diameter and thickness of 2mm; justify the selection of the proper equation, ii) give proper expressions for the Reynolds (Re) and Nusselt (Nu) numbers and explain their roles in the procedure of calculating convective heat transfer coefficients. (d) i) Calculate the total length of the heat exchanger tubes, if the overall heat transfer coefficient is 1070 W m²K-1, ii) explain the general concept of the overall heat transfer coefficient.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter10: Heat Exchangers
Section: Chapter Questions
Problem 10.9P
icon
Related questions
Question
A shell-and-tube heat exchanger is used to cool compressed liquid methanol
from 176 °F to 104 °F. The methanol flows on the shell side of the
exchanger. The coolant is water that rises in temperature from 50 °F to
86 °F and flows within the tubes at a rate of 68.9 kg s-1. Finding the
appropriate thermophysical data and applying the proper equations, you are
required to do the following:
Transcribed Image Text:A shell-and-tube heat exchanger is used to cool compressed liquid methanol from 176 °F to 104 °F. The methanol flows on the shell side of the exchanger. The coolant is water that rises in temperature from 50 °F to 86 °F and flows within the tubes at a rate of 68.9 kg s-1. Finding the appropriate thermophysical data and applying the proper equations, you are required to do the following:
(c) i) Calculate the tube-side convective heat transfer coefficient (h) if the
heat exchanger has 508 tubes of 20 mm outside diameter and
thickness of 2mm; justify the selection of the proper equation, ii) give
proper expressions for the Reynolds (Re) and Nusselt (Nu) numbers
and explain their roles in the procedure of calculating convective heat
transfer coefficients.
(d)
i) Calculate the total length of the heat exchanger tubes, if the overall
heat transfer coefficient is 1070 W m²²K1, ii) explain the general
concept of the overall heat transfer coefficient.
Transcribed Image Text:(c) i) Calculate the tube-side convective heat transfer coefficient (h) if the heat exchanger has 508 tubes of 20 mm outside diameter and thickness of 2mm; justify the selection of the proper equation, ii) give proper expressions for the Reynolds (Re) and Nusselt (Nu) numbers and explain their roles in the procedure of calculating convective heat transfer coefficients. (d) i) Calculate the total length of the heat exchanger tubes, if the overall heat transfer coefficient is 1070 W m²²K1, ii) explain the general concept of the overall heat transfer coefficient.
Expert Solution
steps

Step by step

Solved in 7 steps with 8 images

Blurred answer
Knowledge Booster
Heat Exchangers
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning