A load with an impedance of 424.30245° N is connected to a 100 N lossless line. Using the Smith Chart method, determine the following: (i) The reflection coefficient (ii) The standing wave ratio (iii) The load admittance
Q: three-phase, 60 Hz transmission line has an inductance of 1.378 mH per Km per phase and a…
A: In this question , we will find phase constant , surge impedance and wavelength of lossless line...…
Q: The 50 ohm half wavelength lossless transmission line is terminated with a 60 ohm load impedance. If…
A:
Q: (a) A 3-phase, 50 Hz, 220 kV overhead transmission line is 300 km long. Per km inductance and…
A: We are authorized to answer only 1 question at a time, since you have not mentioned which question…
Q: A single stub tuner is used to match a lossless transmission line of Z, = 75 Q to an antenna load…
A:
Q: A lossless transmission line of electrical length € = 0.32 is terminated with a complex load…
A: Given Data: electrical length l = 0.3 labda ZL = 20 - j 30 ohm Zo = 75 ohm
Q: 6. A 3000 transmission line is 0.8 m long and terminated with a short circuit. The line is operating…
A: z0= 300 ohm, wavelength =0.8m, length =0.8m
Q: For a lossless trabsmisison line, the characteristic impedance is 80 ohm. If the capacitance per…
A: A transmission line can be characterized by 4 parameters: 1. Resistance per unit length (R) in ohm/m…
Q: When a lossless transmission line is terminated by a resistance equal to surge impedance, then what…
A: Given, A lossless transmission line is terminated by a resistance equal to surge impedance. Load…
Q: The capacitance per unit length and the inductance per unit length for a lossless transmission line…
A: Characteristic impedance (Z0) of a transmission line is defined as the impedance of the transmission…
Q: (a) A 602 lossless transmission line is terminated with an antenna of impedance of (27 + j30) N. Use…
A: Hello. Since your question has multiple sub-parts, we will solve first three sub-parts for you. If…
Q: What will be the attenuation constant for a lossless transmission line?
A: Formula for attenuation constant is given by α=12RCL+GLC
Q: lossless transmission line of length 1= = 502, is terminated in a load impedance gnal wavelength on…
A:
Q: Express the velocity of wave on a lossless line in terms of c and z0 with proper derivative. C is…
A:
Q: A loss less transmission line of length 3.125m with characteristic impedance 502, is operating on…
A: Note :- As per guidelines we are supposed to answer only three subparts at a time. So, I request you…
Q: Estimate the characteristic impedance and propagation constant of a lossless transmission line in…
A: Transmission line are expressed in terms of the following line parameters:1. Resistance per unit…
Q: A transmitter delivers 50 W into a 600 Ω lossless line that is terminated with an antenna that has…
A: Brief description : Transmission line is a medium where we can transmit electromagnetic waves…
Q: Derive an expression for sag in a transmission line of equal height poles
A: Consider the diagram for the transmission line between two supports of of equal height as point A…
Q: 1) In a lossy transmission line, what is the formula of the propagation constant (y) of the…
A: As per Bartleby policy we can answer only one question at a time. As you have not mentioned anything…
Q: The static wave ratio in a 300 ( N) lossless transmission line terminating at an unknown load…
A: According to mentioned you solve only (a) part. we have to find the reflection coefficient.
Q: A loss-less 200N line is terminated on a load given by (200-j200)№. Given that the propagation…
A: the Given loss-less 200Ω line is terminated on a load 200-j200Ω The Propagation constant is…
Q: A 5.2cm long, lossless 100Ω transmission line was terminated with a load of ?? = 30 + 50Ω. With the…
A: The load reflection coefficient is: So, the magnitude of the reflection coefficient is: 0.617 And,…
Q: A 3-phase, 60 Hz, 600 kV, lossless transmission line is 600 km long. The line inductance is 2…
A: Given- VL-L=600 kVf = 60 HzL = 2 mH/km/phaseC = 20 nF/km/phase To Find- Phase constant Surge…
Q: Q1) Consider the circuit shown below, with an ideal source connected to a lossless line. Assuming a…
A: Given: Consider the circuit shown below, with an ideal source connected to a lossless line. Assuming…
Q: A 120-22 lossless line is terminated with 40- and 20- resistors in parallel. The voltage a the input…
A:
Q: The static wave ratio in a 300 ( N) lossless transmission line terminating at an unknown load…
A: GIVEN DATA:
Q: c. A lossless 502line is terminated by a load Zı = 75 + j60 2. Using a Smith chart, determine (a)…
A: Given Zo = 50 ohm ZL = 75+j60 ohm
Q: The standing-wave ratio on a lossless 3002 transmission line terminated in an unknown load impedance…
A:
Q: sinusoidal voltage wave is propagating on a low loss transmission line. The voltage as a function of…
A:
Q: A lossless 50 transmission line was terminated with a load of = 17.7 + jl1.8N. The length of the…
A: The solution can be achieved as follows.
Q: 4. For a lossless coaxial transmission line of characteristic impedance 502 and wave phase velocity…
A: For a lossless coaxial transmission line of characteristic impedance 50 Ω and a wave phase velocity…
Q: The return loss for a Transmission line is 20 dB. What will be the value of the corresponding VSWR…
A: During transmission of signal through a transmission line, some portion of the signal always gets…
Q: A 100Ω lossless line connects a matched signal of 100kHz to a load of 25Ω. Calculate the reflection…
A:
Q: Antenna with impedance 40 +j30 2 is to be matched to a 100 Q lossless line with a shorted stub.…
A: Antenna with impedance 40+j30Ω is to be matched to a 100 Ω lossless line with a shorted…
Q: A lossless transmission line has 100 ? characteristic impedance. The line is terminated in a load…
A: Load impedance given is ZL=R-jXC which means it comprises a resistor and a capacitor. The circuit…
Q: A 50Ω lossless transmission line is terminated in a load (50+j100) Ω. Using a smith chart, determine…
A: Given, Impedance, Z0=50ΩLoad Impedance, ZL =(50+j100)Ω
Q: A 602 lossless transmission line is terminated with an antenna of impedance of (27 + j30) Q. Use the…
A:
Q: A lossless transmission line with characteristic impedance of Z0 = 1000 and length I = 52cm was…
A: Given data:
Q: An extra high voltage transmission line of length 300 km can be approximate by a lossless line…
A: Given, An extra high voltage transmission line of length= 300 km Propagation constant, β= 0.00127…
Q: The following lossless network is powered by a f=9,7 GHz microwave source. A matching circuit is…
A: Given, f = 9.7 GHz ZL = 34 L = 270,77835273601
Q: The line parameters of a lossless transmission line are L = 0.25 µH/m and C= 100 pF/m. If the…
A:
Q: A 75 Q lossless transmission line is to be matched with a 100-j802 load using Single stub. Calculate…
A: Given :Z0=75 ΩZL=100-j80 ΩZL=128.06∠38.66° f=30 MHz
Q: Since the input power of a non-reflective and lossless transmission line terminated with a load…
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: Problem #15) Given the system shown below containing a lossless line, Plot the voltage as a function…
A:
Q: A 75N lossless transmission line is terminated with a load impedance equals to 105-j1502. The length…
A: consider the question;
Q: What is the necessary condition for matching transmission lines? In addition, what is a micro strip…
A: Since there are multiple questions uploaded within a single question , thus solving the first…
Q: Return loss for a transmission line in terms of its reflection co efficient is given by:
A: The return loss is a parameter that is used to measure the amount of energy that is reflected back…
Step by step
Solved in 5 steps
- A three-phase power of 460 MW is transmitted to a substation located 500 km from the source of power. With VS=1. per unit, VR=0.9 per unit, =5000 km, Zc=500, and =36.87, determine a nominal voltage level for the lossless transmission line based on Eq. (5.4.29) of the text. Using this result, find the theoretical three-phase maximum power that can be transferred by the lossless transmission line.A lossless 50 ohms transmission line is connected to unknown load impedance. Voltage measurements along the line reveal that the maximum and minimum voltage values are (√2+1)volts and (√2−1) volts respectively. The distance at which maximum voltage is observed has been found to be (15 lamnda(?))/(16). Determine:i. The load reflectionii. Load impedanceiii. The distance (in units of lamnda ?) at which first voltage minimum will be observedA 75 Ω lossless line is terminated in error with a 93 Ω resistor. A generator sends 100 mW down the line.(a) What is the SWR on the line? (b) What is the reflection coefficient?
- Q1) A 70 cm long lossless transmission line with characteristics impedance of 50 Ω operating at 5Mhz is terminated with a load of ?? = (65+j80) Ω. If the velocity is 0.8 times the velocity of light, then calculate (a) The reflection co-efficient, also verify the value using the given smith chart.(b) Compute the input impedance using the transmission line input impedance equation.A 50-ohm lossless transmission line has series inductance of 250 nH/m and shunt capacitance of 100 pF/m. What is the time delay per unit length (in ns/m) of this transmission line? Enter only the numerical value. No need for the unit. Use four decimal places (if the answer is not an interger).An 8000 V, 60 Hz, single-phase, transmission line consists of two hard-drawn aluminumconductors with a radius of 2 cm spaced 1.2 m apart. If the transmission line is 30 km longand the temperature of the conductors is 200C,a. What is the series resistance per kilometer of this line?b. What is the series inductance per kilometer of this line?c. What is the shunt capacitance per kilometer of this line?
- Question#01: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.9 Farad/meter, and 8 Henry/m inductance per meter. The diameter of the inner conductor as 0.8m, and the dielectric constant of the insulation as 4. Find the diameter of the outer conductor in cm. Assume the line is a lossless line?A load of 120 + j150 Ω is connected to a 60 Ω lossless line. Calculate the back reflection coefficient and voltage standing wave ratio (VSWR) values on the line, respectively. Choose the correct optionA lossless transmission line operating at 50 MHz has a surge impedance (40 + j0) ohms and a propagation constant of (0 + j0.5π) per meter. Determine the equivalent inductance (in uH) of the line. Enter only the numerical value. No need for the unit. Use four decimal places (if the answer is not an integer).
- Since the output power of a non-reflective and lossless transmission line terminated with a load impedance of 50 ohms is 10 mW; How many mW should the power applied to the input of the line be?A lossless 50 ohms transmission line is connected to unknown load impedance. Voltage measurements along the line reveal that the maximum and minimum voltage values are (√2 + 1)volts and (√2 − 1) volts respectively. The distance at which maximum voltage is observed has been found to be 15? /16. Determine:i. The load reflectionii. Load impedanceiii. The distance (in units of ?) at which first voltage minimum will be observed. A 70 cm long lossless transmission line with characteristics impedance of 50 Ω operating at 5Mhz is terminated with a load of ?? = (65+j80) Ω. If the velocity is 0.8 times the velocity of light, then calculate (a) The reflection co-efficient, also verify the value using the given smith chart. (b) Compute the input impedance using the transmission line input impedance equation 50 Ω line is terminated with an impedance of ??= (90 – j120) Ω. Design a shortcircuited single stub matching circuit using Smith chart that is provided