A series of undrained shear box tests (area of box = 270 mm2) were carried out on loose soil with the following results as shown in table. If a 28 mm diam. x 72 mm long sample of the same soil was tested in a tri-axial machine, with a cell pressure of 280 kPa. Determine the value of the cohesion (in kPa). Normal load (N) Shear load (N) 90 65 185 88

Principles of Foundation Engineering (MindTap Course List)
9th Edition
ISBN:9781337705028
Author:Braja M. Das, Nagaratnam Sivakugan
Publisher:Braja M. Das, Nagaratnam Sivakugan
Chapter3: Natural Soil Deposits And Subsoil Exploration
Section: Chapter Questions
Problem 3.17P
icon
Related questions
Question
4
A series of undrained shear box tests
(area of box = 270 mm2) were carried
out on loose soil with the following
results as shown in table. If a 28 mm
diam. x 72 mm long sample of the
same soil was tested in a tri-axial
machine, with a cell pressure of 280
kPa. Determine the value of the
cohesion (in kPa).
Normal load (N)
Shear load (N)
90
65
185
88
The value must be a number
Transcribed Image Text:4 A series of undrained shear box tests (area of box = 270 mm2) were carried out on loose soil with the following results as shown in table. If a 28 mm diam. x 72 mm long sample of the same soil was tested in a tri-axial machine, with a cell pressure of 280 kPa. Determine the value of the cohesion (in kPa). Normal load (N) Shear load (N) 90 65 185 88 The value must be a number
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Test for determination of shear strength
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning