ase the speed slightly or decre shunt-field-circuit resistance slightly. Example 8.21(a). A 6-pole dc generator runs at 1200 r.p.m. on no-load and has a generated e.m.f of250 V. Its arma- ture diameter is 350 mm and the radial air-gap between the field poles and the armature is 3 mm. The axial length of the field poles is 260 mm and the field pole effective coverage is 80% including fringing. If the armature has 96 coils having 3 turns per coil and is wound duplex lap, calculate (a) flux per pole (b) effective pole arc length and (c) average air-gap flux 260 mm 350 mm

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.45P
icon
Related questions
icon
Concept explainers
Question
I need answer within 20 minutes please please with my best wishes
the speed slightly or decrease
shunt-field-circuit resistance slightly.
Example 8.21(a). A 6-pole dc generator runs at 1200
r.p.m. on no-load and has a generated e.m.f. of250 V. Its arma-
ture diameter is 350 mm and the radial air-gap between the
field poles and the armature is 3 mm. The axial length of the
field poles is 260 mm and the field pole effective coverage is
80% including fringing. If the armature has 96 coils having 3
turns per coil and is wound duplex lap, calculate (a) flux per
pole (b) effective pole arc length and (c) average air-gap flux
density.
260 mm
350 mm
Transcribed Image Text:the speed slightly or decrease shunt-field-circuit resistance slightly. Example 8.21(a). A 6-pole dc generator runs at 1200 r.p.m. on no-load and has a generated e.m.f. of250 V. Its arma- ture diameter is 350 mm and the radial air-gap between the field poles and the armature is 3 mm. The axial length of the field poles is 260 mm and the field pole effective coverage is 80% including fringing. If the armature has 96 coils having 3 turns per coil and is wound duplex lap, calculate (a) flux per pole (b) effective pole arc length and (c) average air-gap flux density. 260 mm 350 mm
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Thermistors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning