characteristic impedance of Zo=302, load reflection coefficient is 0.5 .What is the load impedance?
Q: A lossless transmission line having 50 Q characteristic impedance and length N4 is open circuited at…
A: Given Lossless transmission line Characteristic impedance Z0=50 ΩLength l=λ4open circuitedVoltage…
Q: For10 m long lossless transmission line L=0.25µH/m and C=100pF/m. It is operating at 600MHZ. Find…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: By using appropriate equation, prove that the input impedance of a terminated Zz + jZ, tan BI Zo +…
A: Lossless Transmission Line A lossless transmission line is defined as a transmission line that has…
Q: three phase, 60 Hz transmission line has an inductance of 1.08 mH per Km per phase and a capacitance…
A: In this question we will find phase constant , surge impedance for lossless line...
Q: (5) Transmission-line analysis: A lossless transmission line of characteristic impedance Zo = 100 2,…
A: Given:Z0=100ΩVp=2×108m/slength, l=34 cmZL=30-j40Ωf=1 GHzλ=Vpfλ=2×108109λ=20 cmlength,l=1.7λ
Q: A lossless transmission with characteristic impedance of ?0 = 100Ω and length = 52cm The line was…
A: Given:Characteristic impedance,Z0=100ΩLoad impedance, ZL=30 +j50Ω
Q: The parameters of a lossless transmission line operating at f=95.493MHz are L′=0.45 μH/m, C′=25…
A:
Q: A lossless transmission line of electrical length € = 0.32 is terminated with a complex load…
A: Given Data: electrical length l = 0.3 labda ZL = 20 - j 30 ohm Zo = 75 ohm
Q: When a lossless transmission line is terminated by a resistance equal to surge impedance, then what…
A: Given, A lossless transmission line is terminated by a resistance equal to surge impedance. Load…
Q: The capacitance per unit length and the inductance per unit length for a lossless transmission line…
A: Characteristic impedance (Z0) of a transmission line is defined as the impedance of the transmission…
Q: If a lossless line is terminated in an inductive load, (a) will the input impedance be purely…
A:
Q: A 40Ω lossless line is connected to an 18V source with Zg = 50Ω and terminated on a ZL = 20Ω load.…
A: Given Lossless line Z0=40 ΩZg=50 ΩZL=20 Ωβ=0.2 rad/mlength from the load L=5 m
Q: A coaxial cable is 10 meters long, and is filled with lossless Teflon, having a relative…
A:
Q: A lossless transmission line is 80 cm in length and operating at a frequency of 140 MHz. The line…
A: Given, Length=80cm=0.8m Frequency=f=140MHz Capacitance=C'=70×0.8=56pF Inductance=L'=0.4×0.8=0.32μH…
Q: A lossless transmission line, with characteristic impedance of 50 N and electrical 2 length of { =…
A: 2. A lossless line is characterized as a transmission line that has no line obstruction and no…
Q: Estimate the characteristic impedance and propagation constant of a lossless transmission line in…
A: Transmission line are expressed in terms of the following line parameters:1. Resistance per unit…
Q: -4. A lossless transmission line has a characteristic impedance of 100 N and is terminated in a load…
A:
Q: A lossless 60 ohm line is terminated by a 60+j60 ohm load .If Zin =120- j60ohm. How far (in term of…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: A lossless coaxial cable with L = 0.5 uH/ft and C = 100 pF/ft is terminated by a 100-ohm resistive…
A: Given that, L = 0.5 uH/ft C = 100 pF/ft ZL= 100-ohm impedance of cable is defined as…
Q: A loss-less 200N line is terminated on a load given by (200-j200)№. Given that the propagation…
A: the Given loss-less 200Ω line is terminated on a load 200-j200Ω The Propagation constant is…
Q: lossless transmission line has a capacitance per unit length of 64pF/m and an inductance per unit…
A:
Q: In a three-phase transmission line with a length of 150 km, a voltage of 250 kV and a frequency of…
A:
Q: A lossless 60-2 line is terminated by a 60 + j60-N load. If Z, = 120 - j60 , how far (in terms of…
A: Reflection coefficients determine how much wave is reflected at discontinuity of medium.It is given…
Q: A lossless air-filled transmission line with Z0 = 50Ω is terminated in a load with ZL = (150 - j100)…
A: Lossless air-filled transmission line with Zo=50Ω is terminated withZL=150-j100Ω.Reflection…
Q: Example 5 (HW): For the lossless TL shown in below with length l and characteristic impedance Z9,…
A: A uniform transmission line's characteristic impedance or surge impedance (commonly written Z0) is…
Q: A lossless transmission line having 50 Ω characteristic impedance and length λ/4 is short-circuited…
A:
Q: The input impedance of lossless /8 transmission line with other end open circuited is given by .…
A: Given: Lossless line Length of the line(l)=λ8Characterstic impedance (Zc)=50 Ω
Q: A lossless transmission line has a capacitance per unit length of 64pF/m and an inductance per unit…
A:
Q: A 60 n lossless line has a maximum impedance Z, = (180 + p) N at a %3! distance of /24 from the…
A: Reflection coefficients determine how much wave is reflected at discontinuity of medium.It is given…
Q: A lossless transmission line has Z₁ = 100 £, terminated by an unknown impedance. The termination is…
A: Given, A lossless transmission line has Z0=100 ΩVSWR=5
Q: In a laboratory, we found that the static wavelength ratio was 2.0 as a result of an experiment…
A: Given :Zo= 50 ohm Standing wave ratio=2.0 The distance between successive voltage minima of 25 cm…
Q: A lossless transmission line of length 50 cm with L = oper ated at 30 MHz. Find phase constant 10…
A: Given: In the given question they have mentioned a lossless transmission line. Lossless…
Q: A lossless transmission line has 100 ? characteristic impedance. The line is terminated in a load…
A: Load impedance given is ZL=R-jXC which means it comprises a resistor and a capacitor. The circuit…
Q: For a lossy transmission line, the characteristic impedance does not depend or a) The operating…
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: line is terminated in -10 volts, use Smith A lossless T.L of 10.25m long with Z-50 2. The…
A:
Q: A lossless transmission line having 50 Ω characteristic impedance and length λ/4 is short-circuited…
A: We know that the input impedance for a loss less transmission line for a quater wave λ4 is given…
Q: QUESTION.2. A lossless air transmission line with Z, = 50 N is connected to a complex load composed…
A:
Q: A losless line assumed to be infinitely long and of unknown characteristic impedance Z,, when…
A: We are given a lossless line to be infinitely long, and it has characteristic impedance of Zx. (1)…
Q: An extra high voltage transmission line of length 300 km can be approximated by a lossless line…
A: Given, An extra high voltage transmission line of length, l = 300 km Propgation constant, β=…
Q: A 50-ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at 100…
A:
Q: A lossless transmission line (TL) has a characteristic impedance of Zo= 250 N, a load impedance of…
A: According to guidelines, we need to solve only the first three subparts. Given, Zo= 250 ohm…
Q: A lossless 60-2 line is terminated by a 60 + j60-2 load. If Zin = 120 - j60 N, how far (in terms of…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: A lossless transmission line having 50 N characteristic impedance and length 1/4 is short circuited…
A: Evaluating the input impedance:
Q: A material with &r = 2.25 is used as the insulating material in a lossless coaxial line with…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: A 75N lossless transmission line is terminated with a load impedance equals to 105-j1502. The length…
A: consider the question;
Q: For the lossless transmission line shown in figure below: (a) Determine Zn at the generator. (b)…
A: The given diagram is shown below, (a) The Zin at the generator, Zin =…
Q: A 60 a lossless line has a maximum impedance Z, = (180 + j0) Q at a distance of /24 from the load.…
A: The EM wave is formed when electric field is in contact with magnetic field. A transmission line is…
Step by step
Solved in 2 steps with 2 images
- The observed standing-wave ratio on a 100-Ω lossless line is 8. If the first maximum voltageoccurs at 0.3λ from the load, calculate the load impedance and the voltage reflection coefficientat the load. (use smith chart) How do you use a smith chart to solve this?The observed standing wave ratio on a 100 Ω lossless line is 8. If the first voltage maximum occurs at 0.3λ from the load, calculate ZL and voltage reflection coefficient at the load.A lossless transmission line has a Zo of 50 ohms and a line velocity of 2.4 x 10^8 m/s. If the operating frequency is 1 MHz. Determine the capacitance in pf.
- For a lossless trabsmisison line, the characteristic impedance is 80 ohm. If the capacitance per unit length is 1.5 mh/m then what will be the inductance per unit length.Topic: Electromagnetic Waves. Please help with this question. The observed standing wave ratio on a 100 Ω lossless line is 8. If the first voltage maximum occurs at 0.3λ from the load, calculate ZL and voltage reflection coefficient at the load.A lossless transmission line l = 0.3lambda in length was terminated with a complex load of ZL = 30-j20 ohms. Find the reflection constant on the load, the standing wave ratio on the line, the reflection constant on the input and the input impedance. Take the characteristic impedance for the line as 75 ohms.
- Stuck on this practice study question. How do solve this transmission problem? A lossless 50-ohm transmission line is terminated in a short circuit. Use the Smith chart to determine: a. The input impedance at a distance 2.3λ from the load. b. The distance from the load at which the input admittance is Yin= -j0.04 SA lossless transmission line having 90 Ω characteristic impedance and length λ/4 is short-circuited at one end and connected to an ideal voltage source of 1V at the other end. Find the current drawn from the voltage sources.A 75 Ω lossless line is terminated in error with a 93 Ω resistor. A generator sends 100 mW down the line.(a) What is the SWR on the line? (b) What is the reflection coefficient?
- The capacitance per unit length and the inductance per unit length for a lossless transmission line are 0.1 F/m and 20 H/m respectively. What will be the characteristic impedance of the line?A lossless transmission line has an inductance of 125 nH/m. Find the velocity factor for this line if the shunt capacitance is 200 nF/m.A load has a reflection coefficient of 0.5 when referred to 50 Ω. The load is at the end of a line with a 50 Ω characteristic impedance.(a) If the line has an electrical length of 45 degrees, what is the reflection coefficient calculated at the input of the line?(b) What is the VSWR on the 50 Ω line?