A lossless transmission line having 50 N characteristic impedance and length 1/4 is short circuited at one end and connected to an ideal voltage source of 1V at the other end. The current drawn from the voltage sources
Q: A lossless transmission line having 50 Q characteristic impedance and length 4 is open circuited at…
A: It is given that: Zccharacterstic impedance=50ΩVgLoad voltage=3VZgLoad impedance=20Ω
Q: For10 m long lossless transmission line L=0.25µH/m and C=100pF/m. It is operating at 600MHZ. Find…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: Smith Chart A quarter-wave lossless 100 N line is terminated by a load Z, the receiving end is 80 V,…
A: for quarter wave length l=λ4=xcharacterstic impedance z0=100Ωload impedance zl=210Ω Line current…
Q: A 50-N lossless line is terminated in Z, = 40 – j30 N. Determine the following: (a) the reflection…
A: A 50Ω lossless line is terminated in Z1=40-j30Ω. Now, to determine the reflection coefficient at the…
Q: A lossless transmission line having a length of 100 metre is terminated by a resistive load of 200…
A: we need to find out transmission loss and return loss.
Q: A lossless transmission line of electrical length € = 0.32 is terminated with a complex load…
A: Given Data: electrical length l = 0.3 labda ZL = 20 - j 30 ohm Zo = 75 ohm
Q: A load with an impedance of 424.3045° N is connected to a 100 N lossless line. Using the Smith Chart…
A:
Q: Q2: (Using Smith chart): Design lossless L-section matching circuits to match the load impedance of…
A:
Q: A lossless transmission line has an inductance of 125 nH/m. Find the velocity factor for this line…
A:
Q: A lossless transmission line has a capacitance per unit length of 64pF/m and an inductance per unit…
A:
Q: Q5: A 50-W lossless line terminated in a purely resistive load has a voltage standing wave ratio of…
A: Here we need to find reflection coefficient first and then we can find ZL.
Q: A transmission line is supported from two towers at heights of 40 m and 58 m above ground level, the…
A:
Q: The capacitance per unit length and the inductance per unit length for a lossless transmission line…
A: Characteristic impedance (Z0) of a transmission line is defined as the impedance of the transmission…
Q: A lossless 34-S transmission line is terminated in a load with ZL= (66+ j26) N. Use the Smith chart…
A:
Q: lossless transmission line of length 1= = 502, is terminated in a load impedance gnal wavelength on…
A:
Q: Estimate the characteristic impedance and propagation constant of a lossless transmission line in…
A: Transmission line are expressed in terms of the following line parameters:1. Resistance per unit…
Q: Q2: For A lossy short-circuited coaxial transmission line, find an input impedance if the…
A: Transmission line- The term transmission line refers to both overhead and underground cables. An…
Q: -4. A lossless transmission line has a characteristic impedance of 100 N and is terminated in a load…
A:
Q: The voltage phasor along a finite lossless transmissionline of characteristic impedance Zo and…
A:
Q: characteristic impedance of Zo=302, load reflection coefficient is 0.5 .What is the load impedance?
A:
Q: A three-phase, 60-Hz, 500-kV transmission line is 300 km long. The line induc tance is 0.97 mH/km…
A: (a) Surge impedance, Zs=LCZs=0.97×10-30.0115×10-6ΩZs=84347.826ΩZs==290.427ΩPhase constant, β=ωLC…
Q: A lossless coaxial cable transmission line has L = 200 uH/ft and C = 100 nF/ft. The inner diameter…
A:
Q: Compute the following parameters inductance, Capacitance, resistance, and conductance, if you have…
A:
Q: A lossless 60 ohm line is terminated by a 60+j60 ohm load .If Zin =120- j60ohm. How far (in term of…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: In a mismatched transmission line with intrinsic impedance of Z, and with a load of impedance of Z,,…
A: A quarter-wave transformer is a basic impedance transformer used in impedance matching to reduce…
Q: A 70 cm long lossless transmission line with characteristics impedance of 50 Ω operating at 5Mhz is…
A: l=70 cm Lossless transmission line Z0=50Ω f=5 Mhz ZL=(65+j80) ΩV=0.8…
Q: At an operating frequency of 300 MHz, it is desired to use a section of a lossless 50 N transmission…
A: Transmission line
Q: b. A lossless 50 ohms transmission line is connected to unknown load impedance. Voltage measurements…
A:
Q: A load with an impedance of 424.30245° N is connected to a 100 N lossless line. Using the Smith…
A: The load impedance is given as, ZL=424.30∠45° ΩAnd The lossline impedance is,Zo=100 Ω
Q: Q2) A lossless transmission line is terminated with a 1002 load. If VSWR on the line is 1.5, fined…
A: Here, we have provided some information about a lossless transmission line. The Voltage Standing…
Q: A lossless transmission line with characteristic impedance of 500 is an unknown load is terminated…
A: According to the question we need to calculate the value of load impedance.
Q: The char. impedance of the trans. line is 50-Ohm and the resistance of it is 0.1Ohm/meter. What will…
A: For the distortion less transmission line the attenuation constant is independent of the frequency.…
Q: A lossless transmission line is terminated with a load impedance of 200 N. The VSWR on the line is…
A:
Q: A lossless transmission line having 50 Ω characteristic impedance and length λ/4 is short-circuited…
A:
Q: A 50 lossless transmission line is terminated by real load impedance of 10002 please answer the…
A: Given, A lossless transmission line has Z0=50 ΩZL=100 Ω
Q: A 50 ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at…
A: Input Impedance- It is define as the opposition to the current offered by the circuit at input end.
Q: A 60 n lossless line has a maximum impedance Z, = (180 + p) N at a %3! distance of /24 from the…
A: Reflection coefficients determine how much wave is reflected at discontinuity of medium.It is given…
Q: -ohm resistive load and is operated at 100 MHz. At an electrical length of 0.4 wavelengths, what is…
A:
Q: A lossless 75-N coaxial cable has a velocity factor of 0.67. For a shorted line at a frequency of…
A:
Q: b) In your own words, define the "skin effect" in transmission lines and discuss how can it be…
A: Skin effect: The non uniform distribution of current through the conductor caused to non uniform…
Q: A lossless transmission line having a characteristic impedance of 500 ohm is terminated with a 600…
A: A transmission line is usually characterized by 4 parameters:1. Inductance per unit length (L)2.…
Q: 3-2. A lossless transmission line has a characteristic impedance of 50 N and is terminated in a load…
A:
Q: Q3 The characteristic resistance of a loss-less transmission line is given by (a) 1/√LC (B)…
A: Q3 The characteristic resistance of a loss-less transmission line is given by (a) 1/√LC (B) √LC…
Q: d) Within the context of power transmission using overhead transmission lines or underground cables,…
A: The basic difference between short and medium length lines is the line parameters which are taken to…
Q: A distortionless transmission line has a resistance per unit length of 0.5 ohm/m. If the…
A: For a transmission line, the following line parameters are present: Since the given transmission…
Q: 1- A lossless transmission line of characteristic impedance 50 ohm is to be matched to a load…
A:
Q: A lossless transmission line has a capacitance per unit length of 64pF/m and an inductance per unit…
A: Characteristics Impedance of Transmission Line: When transmission wave propagated in a transmission…
Q: A lossless transmission line having 50 Ω characteristic impedance and length λ/4 is short-circuited…
A: We know that the input impedance for a loss less transmission line for a quater wave λ4 is given…
Q: A lossless TL with characteristic impedance of to is terminated in Zv=3Z0. use crank diagram to…
A: Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: A 50-ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at 100…
A:
Q: A lossless transmission line (TL) has a characteristic impedance of Zo= 250 N, a load impedance of…
A: According to guidelines, we need to solve only the first three subparts. Given, Zo= 250 ohm…
Q: A lossless 60-2 line is terminated by a 60 + j60-2 load. If Zin = 120 - j60 N, how far (in terms of…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: A material with &r = 2.25 is used as the insulating material in a lossless coaxial line with…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: Zo ER RL
A: Given data, E=128 VZ0=150 ΩRL=450 Ω
Q: A 60 a lossless line has a maximum impedance Z, = (180 + j0) Q at a distance of /24 from the load.…
A: The EM wave is formed when electric field is in contact with magnetic field. A transmission line is…
Q: A 0.875 A section of 50 N lossless line is dr by a source with vg(t) = 10cos(8T * 10°t + 60°) and Z,…
A: As asked in the question we have to calculate the frequency of operation for the given system.
Q: A lossless TL with if the voltage a cross a load connected to lossless TL is 20 Vyms and reflection…
A: This question has multiple sub- parts,we will solve the first 2 sub-parts. If you want the solution…
Find current
Step by step
Solved in 2 steps with 2 images
- If the per-phase line loss in a 70-km-long transmission line is not to exceed 65 kW while it is delivering 100 A per phase, compute the required conductor diameter if the resistivity of the conductor material is 1.72108-m.A single-phase overhead transmission line consists of two solid aluminum conductors having a radius of 3 cm with a spacing 3.5 m between centers. (a) Determine the total line inductance in mH/m. (b) Given the operating frequency to be 60 Hz, find the total inductive reactance of the line in /km and in/mi. (c) If the spacing is doubled to 7 m, how does the reactance change?Calculate the capacitance-to-neutral in F/m and the admittance-to-neutral in S/km for the three-phase line in Problem 4.18. Also calculate the line-charging current in kA/phase if the line is 110 km in length and is operated at 230 kV. Neglect the effect of the earth plane.
- A 500-kV, 300-km, 6()-Hz, three-phase overhead transmission line, assumed to be lossless, has a series inductance of 0.97 mH/krn per phase and a shunt capacitance of 0.0115F/km. per phase. (a) Determine the phase constant p, the surge impedance Zc, velocity of propagation v, and the wavelength of the line (b) Determine the voltage, current, real and reactive power at the sending end, and the percent voltage regulation of the line if the receiving-end load is 800 MW at 0.8 power factor lagging and at 500 kV.In terms of line-to-line capacitance, the line-to-neutral capacitance of a single-phase transmission line is Same Twice One-halfTransmission line conductance is usually neglected in power system studies. True False
- A lossless transmission line having 70 Ω characteristic impedance and length λ/4 is short-circuited at one end and connected to an ideal voltage source of 1V at the other end. Find the current drawn from the voltage sources.A 50-ohm lossless transmission line has series inductance of 250 nH/m and shunt capacitance of 100 pF/m. What is the time delay per unit length (in ns/m) of this transmission line? Enter only the numerical value. No need for the unit. Use four decimal places (if the answer is not an interger).For a lossless trabsmisison line, the characteristic impedance is 80 ohm. If the capacitance per unit length is 1.5 mh/m then what will be the inductance per unit length.
- A lossless transmission line has a Zo of 50 ohms and a line velocity of 2.4 x 10^8 m/s. If the operating frequency is 1 MHz. Determine the capacitance in pf.A 50 ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at 200MHz. At an electrical length of 1.2 wavelengths, what is the input impedance?Stuck on this practice study question. How do solve this transmission problem? A lossless 50-ohm transmission line is terminated in a short circuit. Use the Smith chart to determine: a. The input impedance at a distance 2.3λ from the load. b. The distance from the load at which the input admittance is Yin= -j0.04 S