Example A symmetrical three-phase, three-wire 400 V supply is connected to a delta-connected load as shown. Find its equivalent star-connected load. The phase sequence is positive sequence. 400 v ZR 2.5 260 ZaY 10 230 Zye 10 -45
Q: The voltage across a 3 - phase unbalanced load are Va = 200 ∠40° Vb= 320 ∠ 190° Vc=480 ∠340°.…
A: We have an 3-phase unbalanced load as, Va = 200 ∠40° Vb = 320 ∠190° Vc = 480 ∠340° We have been…
Q: A load connected in delta, with impedances of 24 ≮ 20°, has a current IAC = 20 ≮ 10°, Calculate: a-…
A: In this question, We need to determine the phase current, line current and line to line voltage?…
Q: A balanced three-phase distribution system is shown below. Determine the value of the neutral…
A:
Q: Determine the line currents for the three-phase circuit of Fig. Let Va = 11020°, V = 110Z – 120, V.…
A:
Q: A balanced three-phase star-connected R-C load of 145 kW takes a current of {I} A with a line…
A: Given, P=145 kWVL=900 Vf=50 HzCurrent =I AIL=Iph=I A
Q: Q5/A: A balanced abc sequence star-connected source with Va = 100410° is connected to delta-…
A:
Q: 14. A wye-connected balanced three-phase load draws 75 A from 230 V, 60 Hz, source. To measure the…
A: From the question, it is given that per phase load current of 75 amps . Also, it is given that…
Q: Q2/ A balanced three-phase source serves two loads, as follows: Load 1: 27 kW at 0.9 leading power…
A: In this question, Two loads are connected to the parallel. Load voltage V= 480V, Line impedance…
Q: In a balanced Y-A connected system the source voltage (rms) is given as V = 200/-20° V. Each phase…
A:
Q: 1. A balanced three-phase Y-source with Vph = "E" V rms drives a Y-connected three-phase load with…
A: The circuit diagram is given by:
Q: (1 ZL1 = 3 + j4 M ) 300 kVA 0.9(-) G ZL2 = j5 10/3kV
A: Part (a): It is given that the power factor of the motor is 0.9 lagging. The active power of the…
Q: A balanced three-phase source is supplying 60 kVA at 0.6 lagging to two balanced Y-connected…
A: Draw circuit diagram from given question . Load1 is pure resistive load .Load2 is unknownST=60KvA…
Q: 1. Given:wye-wye(balanced) Three phase generator impedance per phase:0.6+0.10j Three phase load…
A: Given system is star connected. In star connection line voltage is equal to 3 times of phase voltage…
Q: A 220 V, 3-phase voltage is applied to a balanced delta-connected 3-phase lad of phase impedane…
A: Impedance- Impedance is opposition to current flow. Impedance is combine effect of…
Q: Question 3 An unbalanced, three -phase, three-wire, star-connected load is supplied from a balanced…
A: Given Za =28∠37°ΏZb =15∠-78°ΏZc =20∠83° ΏVl =380 V
Q: A single-phase load takes a power of 220 VA at 0.8 lagging power factor when it is connected to a…
A:
Q: Find the line currents in the unbalanced three-phase circuit below and the real power absorbed by…
A:
Q: 2. A balanced three-phase source furnishes power to the following three loads: Load 1: “ M" kVA at…
A: Total load
Q: Assume that the phase-voltage magnitudes for a wye system are 100V. Find the magnitude of the…
A:
Q: In the balanced three-phase Y-A system shown, find the line current I and the average power…
A:
Q: For the following three-phase system. R = 60 X, = 8N EAR = 150 V Vea V. ca ab 3-phase, 3-wire,…
A:
Q: Using Negative Phase Sequence Determine: a) Phase Voltages Power delivered to the load USE3 DECIMAL…
A: The circuit can be redrawn as Here we can see that the given circuit is balanced. So, we can…
Q: 4. A balanced wye-connected, three-phase load withdraws 150 A per phase with a leading power factor…
A: The solution is given below
Q: A balanced star-connected source has phase voltage Vab = 416 ∠30o V and a positive phase sequence.…
A: The source phase voltage is given as:
Q: 19 A balanced three-phase voltage source, Van = 200/0° V rms, positive phase sequence, is connected…
A:
Q: Discuss a balanced 3-phase circuit. f Vab=100<-10°V in a balanced Y-connected 3-phase generator,…
A: A balanced three-phase voltage or current is one in which the size of each phase is the same, and…
Q: 11.25 A balanced abe-sequence of voltages feeds a balanced three-phase wye-wye system. The line and…
A: In this question, We need to determine line voltage Vab? If abc sequence is given with star star…
Q: Q3 In the balanced positive sequence three phase circuit shown below, if Van = A L volt and Zy = (B…
A: In a 3 phase balance supply the phase voltages are seperated by 120o with one another and they have…
Q: The load shown below is connected to a 360 V, 50 Hz three-phase supply with a positive phase…
A: The load shown below is connected to a 360 V, 50 Hz three-phase supply with a positive phase…
Q: A Q.20: For the circuit shown, let Z,=Z2=Z3=60Z30°Q are phase impedances, and the phase voltage be a…
A:
Q: In a balanced three-phase system, the source has an abc sequence, is Y-connected, and Van 126/16° V.…
A:
Q: 3. A balanced star-connected source has phase voltage Vab 416 230° V and a positive phase sequence.…
A: Given Vab=416∠30° VD=50∠30° ΩE=7+j9 Ω Convert both the source and load to their WYE-equivalents.…
Q: A balanced three-phase A-connected load with a phase impedance of 10-j16 Q. If the line voltage is…
A: The complex/ Apparent power in a system is defined as the product of rms value of applied voltage…
Q: 2. A balanced star connected load of impedance (15+j20) ohm per phase is connected to a 3phase…
A: Given: Per phase load impedance = (15 + j20) V2 = 440 Find: 1) IL 2) Power absorbed by the load…
Q: A balanced three-phase A-connected load with a phase impedance of 10-j16 Q. If the line voltage is…
A: A balanced system where all the connected load across voltage are equal . In balanced three phase…
Q: A Z1 Z3 240/0° V 240/-120° V C B 240/120° V
A:
Q: The three-phase balanced load in the figure below has impedance per phase of Zy =6 + 8j ohm. If the…
A: Given, ZY=6+8j ΩVL=220 V
Q: A balanced abc sequence source Vab= 400230° volt is connected to a star- connected (four wires)…
A:
Q: Calculate the line currents in the following 3-phase unbalanced system. Find the active, reactive…
A:
Q: 11.22 In a balanced three-phase wye-wye system, the source is an abc-sequence set of voltages. The…
A: In this question we need to find a input sequence of the line to neutral voltage
Q: AC CIRCU.. 19. A three-phase, three-wire, 240 V CBA system supplies power to a wye-connected load…
A: The solution is given below
Q: b) Figure 4 shows the balanced Wye-Wye connection of Three Phase Circuit. Given Van = 310 V with a…
A:
Q: An unbalance delta connected three phase load shown in the figure is supplied by a balanced three…
A:
Q: Balanced 3 Phase Supply A CC PC S BCN A 90 Balanced 3 Phase Load IN B The 3-phase load consumes a…
A: Methods of power measurement in three phase circuit One wattmeter method Two wattmeter method…
Q: Using two wattmeter method, w2 is connected in line a while w1 is conencted in line c. This is a…
A:
Q: A 220 V, 3-phase voltage is applied to a balanced delta-connected 3-phase load of phase impedanoe…
A:
Q: An unbalance delta connected three phase load shown in the figure is supplied by a balanced three…
A: Note Resistance absorb active power only , it does not take any reactive power Capacitance and…
Q: vs 60 kVA at lagging PF of 0.8, while load 2 draws 26.667 ume no line resistance and Vab-440L 30°…
A: In this question given 2 loads ...We have to find out total power dream by loads , phase currents…
Q: 1. A balanced three-phase Y-source with Vph = "E" V ms drives a Y-connected three-phase load with…
A: Given that balanced three phase Y connected load with Y connected source . Ea =214∠0 Volt Eb…
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 1 images
- Two balanced Y-connected loads, one drawing 10 kW at 0.8 power factor lagging and the other IS kW at 0.9 power factor leading, are connected in parallel and supplied by a balanced three-phase Y-connected, 480-V source. (a) Determine the source current. (b) If the load neutrals are connected to the source neutral by a zero-ohm neutral wire through an ammeter, what will the ammeter read?Consider a three-phase Y-connected source feeding a balanced- load. The phasor sum of the line currents as well as the neutral current are always zero. (a) True (b) FalseConsider a 10 kVA, 200/400 V, 50 HZ: single-phase tranformer has the folloving test results:0.C. test: 200 V, 0.6A, 63 W (L.V.side)S.C. test : 20 V, 25A, 85 W (H.V. side)Deternine:i- The eficiengy at 75 % offiull-load at 0.9 leading power factor.ii -The secondary terminal voltage on fill-load at tunity power facton
- A balanced delta load of -j60 impedance is fed by a balanced three-phase generator of negligible series impedance. The generator has an armature voltage in phase "c" of 200<30° Vrms. Indicate what is the value of the current Ibc circulating in the deltaA load connected in star, with impedances of 24 ≮ 20°, has a voltage Vac = 208 ≮ 10°, Calculate:a- Phase currentsb- The phase voltagesc- Line-Line voltagesA balanced load of phase impedance 100Ω and power factor 0.8 is connected to a400 V, 3-phase supply (a) in star, and (b) in delta. Calculate and compare the powerdissipation in each case.
- A balanced load of phase impedance 100 ohms and power factor 0.8 is connected (a) in star ,and (b) in delta ,to a 400V, 3 phase supply calculate the power dissipation in each caseA three-phase balanced load of 15A per phase is supplied by a steel wire armoured cable with a c.s.a. of 2.5mm². The voltage drop for this cable is 15mv/A/m and the circuit is 40m long. Calculate the voltage drop in the cable.A delta-connected load with impedance Zab= 10cis30, Zbc = 25cis0 und Zca= 20cis-30 ohm is connected to a three phase, three-wire 250-volt source with phase sequence ab-bc-ca. Find the line currents and the total power.
- A balanced three-phase source with grounded neutral has line-to-line voltages of 236 volts with ab-bc-ca sequence. It supplies power to an unbalanced three-phase delta load with impedances: Zab = 72 cis 69; Zbc = 90 cis -64; Zca = 53 cis 22 ohms. Determine the magnitude of the line current, Ia amperes.A delta-connected load has the following parameters, Zab= 75Ω, Zbc= 80 + j60 Ω, and Zca= 50 -j60 Ω. The circuit is connected in a 240-V three phase supply with a positive sequence. Compute for the line currentsand the total real power delivered. Show full and complete solutionTwo single-phase loads are connected in parallel, where load 1 is 4.7 kVA at 0.87 lagging power factor, and load 2 is5.2 kWat0.79lagging power factor. The load combination is connected to a voltage source of220VAC,50 Hz. a) Find the total complex power