Figure 1 shows a generating station feeding power to a system. This line is 200 km long. What is the total fault current when the system experiences three-phase symmetrical fault at the receiving end of the bus? Use these base values: 126 MVA, 19 kV at the generator side, and 149 kV for the feeder side Generator 1 ratings: 126 MVA, 19 kV, j0.19 Generator 2 ratings: 90 MVA, 19 kV, jo.12 Transformer 1 ratings: 126 MVA, 19/149 kV, jo.1 Transformer 2 ratings: 90 MVA, 19/149 kV, jo.09 Transmission line 1 rating: 0.2 ohm per phase per km Transmission line 2 rating: 0.7 ohm per phase per km

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.7P
icon
Related questions
Question
Figure 1 shows a generating station feeding power to a system. This line is 200 km long.
What is the total fault current when the system experiences three-phase symmetrical fault at the receiving end of the bus? Use
these base values: 126 MVA, 19 kV at the generator side, and 149 kV for the feeder side
Generator 1 ratings:
126 MVA, 19 kV, jo.19
Generator 2 ratings:
90 MVA, 19 kV, jo.12
Transformer 1 ratings:
126 MVA, 19/149 kV, jo.1
Transformer 2 ratings:
90 MVA, 19/149 kV, jo.09
Transmission line 1 rating:
0.2 ohm per phase per km
Transmission line 2 rating:
0.7 ohm per phase per km
Transcribed Image Text:Figure 1 shows a generating station feeding power to a system. This line is 200 km long. What is the total fault current when the system experiences three-phase symmetrical fault at the receiving end of the bus? Use these base values: 126 MVA, 19 kV at the generator side, and 149 kV for the feeder side Generator 1 ratings: 126 MVA, 19 kV, jo.19 Generator 2 ratings: 90 MVA, 19 kV, jo.12 Transformer 1 ratings: 126 MVA, 19/149 kV, jo.1 Transformer 2 ratings: 90 MVA, 19/149 kV, jo.09 Transmission line 1 rating: 0.2 ohm per phase per km Transmission line 2 rating: 0.7 ohm per phase per km
...
T1
XLT
(GI
XL2
Tz
G23
Transcribed Image Text:... T1 XLT (GI XL2 Tz G23
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Similar questions
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning