For a one port network, explain the effect on the admittance frequency characteristics when it has a series (i) inductor path (ii) capacitor path [Hint: poles and zeros] el, R
Q: A lossless transmission line having 50 Q characteristic impedance and length N4 is open circuited at…
A: Given Lossless transmission line Characteristic impedance Z0=50 ΩLength l=λ4open circuitedVoltage…
Q: A lossless transmission line having 50 Q characteristic impedance and length 4 is open circuited at…
A: It is given that: Zccharacterstic impedance=50ΩVgLoad voltage=3VZgLoad impedance=20Ω
Q: b) Write ABCD Parameters of the nominal Tt model of the medium transmission line.
A:
Q: Q4: A 3-phase, 50Hz, 150 km line has a resistance, inductive reactance and capacitive shunt…
A:
Q: 2- Transmission line 10m long has distributed parameters R = 5 Ω /m, L = 6μH/m, G = 10 mS/m, and C =…
A:
Q: Q1/Open and short circuit termination measurements on a telephone cable 50 Km long, at an angular…
A: Given ω=5000 rad/secZOC=328∠-29.2°ΩZSC=1548 ∠6.8°find ZO, L, R, G. C
Q: instructions Derive and express the Scattering Parameters interms of Admittance, transmission, and…
A:
Q: )A 60-ohm distortionless transmission line has a capacitance of 0.15nF/m. The…
A: here, the given line is the distortionless transmission line so, the condition of the distortionless…
Q: Line parameters of a transmission line at 2 GHz are R = 10 mn/m, G = 1 µS/m, L = 1 µH/m, C = 1 nF/m…
A: The given circuit diagram is shown below: It is given that: R=10 mΩ/m=10×10-3 Ω/mG=1 μS/m=1×10-6…
Q: QB2 (a) Determine whether the following statement is true or false. Explain your answer. Statement:…
A: The solution is given below
Q: Q4. A 3-phase, 60 Hz, 500-kV transmission line is 300 km long. The line inductance is 0.97 mH/km per…
A:
Q: Q5.For a transmission line with resistance, R, reactance X, and negligible capacitance, the…
A: Step 1 Resistance = R Reactance =X Capacitance is negligibleSince capacitance is negligible it is…
Q: Choose the correct answer for the following; • The components of the propagation constant are named…
A: Since you have asked multiple questions in a single request, we will be answering only the first…
Q: A three-phase, 60-Hz, 69-kV transmission line has an inductance of 1.0531 mH/Km per phase and a…
A: In this question, We need to choose the correct options What is the transmission line parameter A?…
Q: A transmission line has the following per-unit-length parameters: L = 0.5 µH/m, C = 200 pF/m, R =…
A: Given Data: R = 4 ohm L = 0.5 uH C = 200 pF G = 0.02
Q: A lossless transmission line has a distributed inductance of 10 pH per meter and a distributed shunt…
A: Given data : Distributed inductance L=10×10-6H/m For 4m length L=10×10-6×4 =40×10-6 Distributed…
Q: Hybrid Coupler ODU (Out Door Unit) Antenna RF Frequency e.g. 7GHZ Waveguide Intermediate Frequency…
A: Diversity in Microwave: Diversity refers to an improvement in reliability for the transmission and…
Q: Q8) A transmission line has the following per unit length parameters: L-0.2 µH/m C=300 pF/m R=5 2/m…
A: Given data: L=0.2μH/mC=300 pF/mR=5ΩG=0.02S/mf=500 MHz
Q: 2- Transmission line 10m long has distributed parameters R = 5 Q /m, L = 6µH/m, G= 10 mS/m, and C =…
A:
Q: A 60 Hz, single-circuit, three-phase transmission line is 150 mi long. The line is connected to a…
A:
Q: The per-phase constants of a 345-kV, three- phase, 150-km-long transmission line are resistance =…
A: we have given the per-phase constants of a 345-kV three phase 150km long transmission line are…
Q: The inductances per phase and capacitance per phase of a three-phase, 50H z, 450KV transmission line…
A:
Q: b) Write ABCD Parameters of the nominal T model of the medium transmission line.
A:
Q: B-For the lossless transmission lines circuit shown below, design the value of Rx for proper series…
A: Given figure,
Q: Tt=3.14 For a Transmission line, L=6,4 nH/m, R=2,9 0/m, C=1,2 µF/m and G=8,5 S/m (f = 1 GHz). For…
A: According to the question we have to find the value of ZR.
Q: The components of the propagation constant are named as For long transmission line system, The…
A: Given *The components of the propagation constant are named as…
Q: Voltage Regulation (VR) is the change in the voltage at the receiving end of the line when the load…
A:
Q: A lossless transmission line, with characteristic impedance of 50 N and electrical 2 length of { =…
A: 2. A lossless line is characterized as a transmission line that has no line obstruction and no…
Q: The per-phase constants of a 345-kV, three-phase, 150-km-long transmission line are resistance = 0.1…
A: we need to determine the sending-end voltage.
Q: For a STABLE LTI system, all the poles of the system function H(z) must lie inside the unit circle.…
A: The LTI system is considered as stable when the bounded input provide a bounded input.
Q: A three-phase, 60-Hz, 500-kV transmission line is 300 km long. The line induc tance is 0.97 mH/km…
A: (a) Surge impedance, Zs=LCZs=0.97×10-30.0115×10-6ΩZs=84347.826ΩZs==290.427ΩPhase constant, β=ωLC…
Q: In a mismatched transmission line with intrinsic impedance of Z, and with a load of impedance of Z,,…
A: A quarter-wave transformer is a basic impedance transformer used in impedance matching to reduce…
Q: 3. Determine the sending end voltage, V, of the given nominal-T transmission line.
A:
Q: a) Discuss the use of hyperbolic functions and Taylor series when modelling the long transmission…
A: The transmission lines have their own resistance, inductance and capacitance. The transmission lines…
Q: A 40-km, 220-kV, 60-Hz three-phase overhead transmission line has a per-phase resistance of 0.15…
A:
Q: In which Transmission Line classification is Capacitance negligible in its Equivalent Circuit? A.…
A: Short Transmission Line Only In short transmission line capacitance is negligible because of small…
Q: A 60-ohm distortionless transmission line has a capacitance of 0.15nF/m. The attenuation of the line…
A: Given data Z0=60 ΩC=0.15 nF/mα=1.15×10-3 Np/m i) Expression of characteristic impedance Z0=LC…
Q: The open-circuit and short-circuit impedances measured at the input terminals of an air- spaced…
A:
Q: 2- Transmission line 10m long has distributed parameters R = 52/m, L = 6µH/m, G= 10 mS/m, and C = 25…
A:
Q: From the given expressions of the parameters of medium length transmission line, which one will have…
A: The medium length transmission line parameters in nominal-T model are ABCD=1+ZY2ZY1+ZY2
Q: Derive and express the Scattering Parameters interms of Admittance, transmission, and hybird…
A: Sig =Normalized reflected wave at ith partNormalized incident wave of jth part= biaj Normalized…
Q: Representing a transmission line by the two-port network, in terms of ABCD parameters, (a) express…
A: The two port network is represented as shown below:
Q: In a double side-band (DSB) full carrier AM transmission system, if the modulation index is doubled,…
A: The efficiency of a double sideband full carrier transmission system is the ratio of the signal…
Q: A 400kV, 200km, 3-phase transmssion line have the follollowing parameters per phase: z= 0.14+j0.304…
A:
Q: Q3: A lossy transmission line has a complex propagation constant of y 0.012+5.8 (/m). If the voltage…
A: Given,Y=0.012+j5.8 /mV0=12Voltz=d=12 mWe know that,V=V0e-αz Equation 1where α is…
Q: When analyzing Short Transmission Lines, it is assumed that the Sending and Receiving Ends should be…
A: A short transmission line has an effective length less than 80 km. The line charging current is…
Q: A 400kV, 200km, 3-phase transmssion line have the follollowing parameters per phase: z = 0.14+j0.304…
A:
Q: Transmission line 10m long has distributed parameters R = 5 Ω /m, L = 6µH/m, G = 10 mS/m, and C = 25…
A: (A): The characteristics impedance is:…
Q: ) Write ABCD Parameters of the nominal π model of the medium transmission line.
A:
Q: For a one port network, explain the effect on the admittance frequency characteristics when it has a…
A: In the question, What is effect of frequency in admittance of path if Element(either indotor Or…
Step by step
Solved in 2 steps with 2 images
- Optical Fibre communication link: Discuss the results in regards to power transmitted (dBM) Vs The Optical Length. Clear explanationAt what condition in a circuit, does it becomes necessary to use the transmission line theory?Describe in detail the matched vs. mis-matched transmission lines.Design a ‘π’ equivalent circuit for 320 km long 3-φ, 50 Hz transmission line.The line is composed of Drake conductors with the outside diameter of 2.8 cm and flat horizontal spacing of 3.65 m between adjacent conductors. The line has a resistance of 0.075 Ω/km.
- Explain Transmitted power (dBm) and Optical link length (km) in Optical Communication Link analysis.HIGH VOLTAGE . A 132 kV, three-phase, 50Hz transmission line uses 18 mm diameter, equally spaced ACSR conductors. Determine the spacing between these conductors, if it is to be designed such that the corona inception voltage is 5% higher than the normal operating voltage of the line at 40o You may assume the expression relating the electric field and the voltage of the line as a starting point.With the system shown in the figure, use 100MVA as system base, and 230 kV as base voltage along the transmission line. For the same system in the figure, build the Y-bus matrix without the Load. 1. What is the element Y11? Provide the susceptance value 2. What is the element Y22? Provide the susceptance value
- )A 60-ohm distortionless transmission line has a capacitance of 0.15nF/m. The attenuation of the line 1.15*10-3 Np/m. Calculate: (i) The line parameter resistance, inductance and conductance per meter of the line, (ii) Voltage at a distance of 1Km and 4Km with respect to sending voltage.Identify the types of transmission mediums used for the following examples: -[Your answer should contain the exact type of the media (e.g. twistedpair,coaxial, radiowave etc.), NOT guided and unguided media only.]a. Long-haul networkb. LEO satellite networkc. 4G mobile networksWith a neat diagram show the reflections occurring in a transmission line. Hence explain thec conceptsof Reflection co-efficient and VSWR associated with it.
- Find the short circuit current at the D point with the bus-admittance method of the system, whose reactance equivalent is given below.(SB=175MVA UB=154KV)A simple point-to-point microwave transmission link has no redundancy. Failure of the link will result in an outage. Therefore, typical microwave transmission links are designed with redundancy. Explain the following redundancy techniques 1+1 Hot Standby (HSB), 1+1 Space Diversity (SD), and 1+1 FD (Frequency Diversity).please explain.A 132 kV, three-phase, 50Hz transmission line uses 18 mm diameter, equally spaced conductors. Determine the spacing between these conductors, if it is to be designed such that the corona inception voltage is 5% higher than the normal operating voltage of the line at 40oC. (You may assume the expression relating the electric field and the voltage of the line as a starting point, m=0.9)