Hot water is transported from a cogeneration power station to commercial and industrial users through steel pipes of diameter D= 150 mm, with each pipe centered in concrete (k= 1.4 W/m-K) of square cross section (w= 300 mm). The outer surfaces of the concrete are exposed to ambient air for which T = 0°C and h = 25 W/m²-K. Concrete, k Air Water T, m (a) If the inlet temperature of water flowing through the pipe is T¡ = 90 °C, what is the heat loss per unit length of pipe in proximity to the inlet? The temperature of the pipe T¡ may be assumed to be that of the inlet water. (b) If the difference between the inlet and outlet temperatures of water flowing through a 100-m- long pipe is not to exceed 5°C, estimate the minimum allowable flow rate in . The effect of small temperature drop along the pipe on the heat rate may be ignored. The specific heat of the water is c = 4207 J/kg-K.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter3: Transient Heat Conduction
Section: Chapter Questions
Problem 3.10P: 3.10 A spherical shell satellite (3-m-OD, 1.25-cm-thick stainless steel walls) re-enters the...
icon
Related questions
Question

Hot water is transported

Hot water is transported from a cogeneration power station to commercial and industrial users
through steel pipes of diameter D= 150 mm, with each pipe centered in concrete (k= 1.4 W/m-K)
of square cross section (w= 300 mm). The outer surfaces of the concrete are exposed to ambient
air for which T = 0°C and h = 25 W/m²-K.
Concrete, k
Air
Water
T, m
(a) If the inlet temperature of water flowing through the pipe is T¡ = 90 °C, what is the heat loss
per unit length of pipe in proximity to the inlet? The temperature of the pipe T¡ may be assumed
to be that of the inlet water.
(b) If the difference between the inlet and outlet temperatures of water flowing through a 100-m-
long pipe is not to exceed 5°C, estimate the minimum allowable flow rate in . The effect of
small temperature drop along the pipe on the heat rate may be ignored. The specific heat of the
water is c = 4207 J/kg-K.
Transcribed Image Text:Hot water is transported from a cogeneration power station to commercial and industrial users through steel pipes of diameter D= 150 mm, with each pipe centered in concrete (k= 1.4 W/m-K) of square cross section (w= 300 mm). The outer surfaces of the concrete are exposed to ambient air for which T = 0°C and h = 25 W/m²-K. Concrete, k Air Water T, m (a) If the inlet temperature of water flowing through the pipe is T¡ = 90 °C, what is the heat loss per unit length of pipe in proximity to the inlet? The temperature of the pipe T¡ may be assumed to be that of the inlet water. (b) If the difference between the inlet and outlet temperatures of water flowing through a 100-m- long pipe is not to exceed 5°C, estimate the minimum allowable flow rate in . The effect of small temperature drop along the pipe on the heat rate may be ignored. The specific heat of the water is c = 4207 J/kg-K.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Applied Fluid Mechanics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning