In the following power system, overcurrent relay R₁2 is to provide primary protection to line 1-2 and overcurrent relay R₂3 is to provide primary protection to line 2-3. For both relays the CT ratio is 200:5. The min and max currents for faults on lines 1-2 and 2-3 are shown. Maximum load current is 200 A. 3 IF.min 0.8kA R23 R12 IF.min IF,max = 1.5kA =4.0KA IF max = 2.7KA 1 ·+· If R₁2, R₂3 are inverse, time-delay overcurrent relays, what should their pickup current (secondary current) and time dial settings be if a minimum coordination time of 0.5 second is required? The relay operating characteristics are shown on the following page.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter10: System Protection
Section: Chapter Questions
Problem 10.17P
icon
Related questions
icon
Concept explainers
Question
In the following power system, overcurrent relay R₁2 is to provide primary protection to line 1-2
and overcurrent relay R23 is to provide primary protection to line 2-3. For both relays the CT
ratio is 200:5. The min and max currents for faults on lines 1-2 and 2-3 are shown. Maximum
load current is 200 A.
3
I
F,min
R12
= 1.5kA
=0.8kA
R23
F,min
IF.max=4.0kA
IF max
= 2.7KA
If R₁2, R₂3 are inverse, time-delay overcurrent relays, what should their pickup current
(secondary current) and time dial settings be if a minimum coordination time of 0.5 second is
required? The relay operating characteristics are shown on the following page.
Transcribed Image Text:In the following power system, overcurrent relay R₁2 is to provide primary protection to line 1-2 and overcurrent relay R23 is to provide primary protection to line 2-3. For both relays the CT ratio is 200:5. The min and max currents for faults on lines 1-2 and 2-3 are shown. Maximum load current is 200 A. 3 I F,min R12 = 1.5kA =0.8kA R23 F,min IF.max=4.0kA IF max = 2.7KA If R₁2, R₂3 are inverse, time-delay overcurrent relays, what should their pickup current (secondary current) and time dial settings be if a minimum coordination time of 0.5 second is required? The relay operating characteristics are shown on the following page.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Protection System in Power Plant
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning