Q2) A 4 pole, lap wound, compound DC generator has an armature resistance of 0.2 Q, series field resistance of 0.12 and a shunt field resistance of 220 Q. The generator supplies the following loads as follows, Load 1 (L1): 200 Lamps, each lamp is rated at 40 W, at a terminal voltage of 220 V. Load 2 (L2): A 5 KW heater at a terminal voltage of 220 V. The machine has 1000 conductors, assume long shunt connection, a) Calculate the total load current. b) Find the generated voltage, Eg and total load power. c) If all lights are turned off, calculate the generated voltage of the machine, Eg, and the speed of the machine,. if flux is 20 mwb/pole.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q2) A 4 pole, lap wound, compound DC generator has an armature resistance of 0.2 Q, series
field resistance of 0.12 and a shunt field resistance of 220 Q. The generator supplies the
following loads as follows,
Load 1 (L1): 200 Lamps, each lamp is rated at 40 W, at a terminal voltage of 220 V.
Load 2 (L2): A5 KW heater at a terminal voltage of 220 V.
The machine has 1000 conductors, assume long shunt connection,
a) Calculate the total load current.
b) Find the generated voltage, Eg and total load power.
c) If all lights are turned off, calculate the generated voltage of the machine, Eg, and the
speed of the machine,. if flux is 20 mwb/pole.
Transcribed Image Text:Q2) A 4 pole, lap wound, compound DC generator has an armature resistance of 0.2 Q, series field resistance of 0.12 and a shunt field resistance of 220 Q. The generator supplies the following loads as follows, Load 1 (L1): 200 Lamps, each lamp is rated at 40 W, at a terminal voltage of 220 V. Load 2 (L2): A5 KW heater at a terminal voltage of 220 V. The machine has 1000 conductors, assume long shunt connection, a) Calculate the total load current. b) Find the generated voltage, Eg and total load power. c) If all lights are turned off, calculate the generated voltage of the machine, Eg, and the speed of the machine,. if flux is 20 mwb/pole.
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Knowledge Booster
DC Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,