Q2: A Freon -12 installation has the following data: Сараcity: Evaporator temperature : Condenser temperature : Temperature of refrigerant superheated as gas in evaporator : Temperature of refrigerant sub-cooled as liquid in condenser : Compressor particulars: number of cylinders: bore (D)= 1.5 times stroke Determine: (i) refrigerating effect / kg, (i) mass of refrigerant circulating / min, iii) theoretical power condenser 15 ton - 10°C. 30°C - 5°C to 25°C 2 r.p.m. = 960 n-0.945 [Note. 210 kJ/min-1 tone] %3D (iv) co-efficient of performance, (v) heat removed in (vi) bore and stroke of compressor.

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter2: Matter And Energy
Section: Chapter Questions
Problem 29RQ: If 3000 ft3 of air is crossing an evaporator coil and iscooled from 75F to 55F, what would be the...
icon
Related questions
Question
i need the answer quickly
Q2: A Freon -12 installation has the following data:
Capacity :
Evaporator temperature :
Condenser temperature :
Temperature of refrigerant superheated as gas in evaporator :
Temperature of refrigerant sub-cooled as liquid in condenser :
Compressor particulars: number of cylinders:
bore (D)= 1.5 times stroke
Determine: (i) refrigerating effect /kg, (i) mass of refrigerant circulating / min,
(iii) theoretical power
condenser
15 ton
- 10°C.
30°C
-5°C
Lo 25°C
2
r.p.m. = 960 =0.945
[Note. 210 kJ/min=1 tone]
(iv) co-efficient of performance, (v) heat removed in
(vi) bore and stroke of compressor.
Transcribed Image Text:Q2: A Freon -12 installation has the following data: Capacity : Evaporator temperature : Condenser temperature : Temperature of refrigerant superheated as gas in evaporator : Temperature of refrigerant sub-cooled as liquid in condenser : Compressor particulars: number of cylinders: bore (D)= 1.5 times stroke Determine: (i) refrigerating effect /kg, (i) mass of refrigerant circulating / min, (iii) theoretical power condenser 15 ton - 10°C. 30°C -5°C Lo 25°C 2 r.p.m. = 960 =0.945 [Note. 210 kJ/min=1 tone] (iv) co-efficient of performance, (v) heat removed in (vi) bore and stroke of compressor.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Dimensional Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning