Q2 / For the connection of Figure 2, in terms of switching surge, when the second terminal of CB is shorting the circuit to the earth, answer the following questions: 1- Plot the equivalent electrical RLC circuit expressing the circuit case. 2- Explain the effect of R, L, and C values on the shape of generated oscillation. 3- Determine the relative attenuation occurring in three cycles in the overvoltage surge set up on a 75 kV cable fed through an air-blast circuit breaker when the breaker opens on a system short circuit. The network parameters are as follows: R= 8.5 0, L = 7.1mH, C= 0.0516 µF

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter13: Transmission Lines: Transient Operation
Section: Chapter Questions
Problem 13.24P
icon
Related questions
Question

Please solve as soon as possible

Q2 / For the connection of Figure 2, in terms of switching surge, when the second terminal of
CB is shorting the circuit to the earth, answer the following questions:
1- Plot the equivalent electrical RLC circuit expressing the circuit case.
2- Explain the effect of R, L, and C values on the shape of generated oscillation.
3- Determine the relative attenuation occurring in three cycles in the overvoltage surge
set up on a 75 kV cable fed through an air-blast circuit breaker when the breaker opens
on a system short circuit. The network parameters are as follows:
R= 8.5 0, L = 7.1mH, C= 0.0516 µF
CB
= Om
VLC
Restriking voltage
(expanded time
scale)
R
21
Maximum Voltage V = 1.633 x Surge voltage
v(t) = V[1 -e cos ont]
Arc voltage
Time
System
voltage
CB open circuit
Fault current
Figure: 2
Transcribed Image Text:Q2 / For the connection of Figure 2, in terms of switching surge, when the second terminal of CB is shorting the circuit to the earth, answer the following questions: 1- Plot the equivalent electrical RLC circuit expressing the circuit case. 2- Explain the effect of R, L, and C values on the shape of generated oscillation. 3- Determine the relative attenuation occurring in three cycles in the overvoltage surge set up on a 75 kV cable fed through an air-blast circuit breaker when the breaker opens on a system short circuit. The network parameters are as follows: R= 8.5 0, L = 7.1mH, C= 0.0516 µF CB = Om VLC Restriking voltage (expanded time scale) R 21 Maximum Voltage V = 1.633 x Surge voltage v(t) = V[1 -e cos ont] Arc voltage Time System voltage CB open circuit Fault current Figure: 2
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Coulomb's law
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning