Q2. (a) Explain what is per unit system? What are the advantages of per-unit computations? Prove for the problem given in part (b) that PU impedance of the circuit element connected by the transformers expressed on a proper base will be same if it is referred to either side of a transformer. (b) A 3-phase, A-Y transformer with rating 100 kVA, 11 kV/400 V has its primary and secondary leakage reactance as 122/phase and 0.052/phase respectively. Determine the PU reactance of transformer referred to primary side and then secondary side to prove that it will be same.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.13MCQ: Consider the adopted per-unit system for the transformers. Specify true or false for each of the...
icon
Related questions
Question
Q2
Q2. (a) Explain what is per unit system? What are the advantages of per-unit computations? Prove for
the problem given in part (b) that PU impedance of the circuit element connected by the transformers
expressed on a proper base will be same if it is referred to either side of a transformer.
(b) A 3-phase, A-Y transformer with rating 100 kVA, 11 kV/400 V has its primary and secondary leakage
reactance as 120/phase and 0.052/phase respectively. Determine the PU reactance of transformer
referred to primary side and then secondary side to prove that it will be same.
Transcribed Image Text:Q2. (a) Explain what is per unit system? What are the advantages of per-unit computations? Prove for the problem given in part (b) that PU impedance of the circuit element connected by the transformers expressed on a proper base will be same if it is referred to either side of a transformer. (b) A 3-phase, A-Y transformer with rating 100 kVA, 11 kV/400 V has its primary and secondary leakage reactance as 120/phase and 0.052/phase respectively. Determine the PU reactance of transformer referred to primary side and then secondary side to prove that it will be same.
Expert Solution
steps

Step by step

Solved in 5 steps with 5 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning