QUESTION 2 (a) A multirange ammeter needs to be designed with four measurement ranges: PIS Come to Uha uhata Range 1:0 – 1 mA +6-17291720g Range 2: 0 – 20 mA Range 3: 0 – 50 mA Range 4: 0 - 100 mA fo G A D'Arsonval meter movement with an internal resistance of 500 2 and full scale ay tent current of 100 µA is used. i) Design each resistor values for the multirange ammeter using the principle of Aryton Shunt. ii) If you were to construct this ammeter, how would you arrange the resistors? nongi Sketch a schematic diagram to show your design.

Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter4: Electric Meters
Section: Chapter Questions
Problem 2RQ
icon
Related questions
Question
QUESTION 2
(a)
A multirange ammeter needs to be designed with four measurement ranges:
PIS Come to wha
+6-172917209
Range 1: 0 – 1 mA
Range 2: 0 – 20 mA
Range 3: 0 – 50 mA
Range 4: 0 – 100 mA
foC
A D’Arsonval meter movement with an internal resistance of 500 SN and full scale
Ray
current of 100 µA is used.
i)
Design each resistor values for the multirange ammeter using the principle of
Aryton Shunt.
wak
ii)
If
you were to construct this ammeter, how would you arrange the resistors?
Sketch a schematic diagram to show
your design.
mongy
(b)
multirange DC voltmeter can be designed either with the multiplier resistors
connected in shunts or in series.
bwena
D'Arsonval meter movement with Im = 100 µA and Rm
1.4 kQ is to be
converted into a multirange DC voltmeter for ranges of 5 V, 10 V, 20 V and 50
V. Calculate the multiplier resistor values for both types of design.
ii)
Based on the calculation results, give your opinion on which design is better
and provide your reason.
Transcribed Image Text:QUESTION 2 (a) A multirange ammeter needs to be designed with four measurement ranges: PIS Come to wha +6-172917209 Range 1: 0 – 1 mA Range 2: 0 – 20 mA Range 3: 0 – 50 mA Range 4: 0 – 100 mA foC A D’Arsonval meter movement with an internal resistance of 500 SN and full scale Ray current of 100 µA is used. i) Design each resistor values for the multirange ammeter using the principle of Aryton Shunt. wak ii) If you were to construct this ammeter, how would you arrange the resistors? Sketch a schematic diagram to show your design. mongy (b) multirange DC voltmeter can be designed either with the multiplier resistors connected in shunts or in series. bwena D'Arsonval meter movement with Im = 100 µA and Rm 1.4 kQ is to be converted into a multirange DC voltmeter for ranges of 5 V, 10 V, 20 V and 50 V. Calculate the multiplier resistor values for both types of design. ii) Based on the calculation results, give your opinion on which design is better and provide your reason.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 3 images

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning