Question Four a) The concentration of As(III) in water can be determined by differential pulse polarography in IM HCI. The initial potential is set to-0.1 V versus the SCE, and is scanned toward more negative potentials at a rate of 5 mV/s. Reduction of As(III) to As(0) occurs at a potential of approximately -0.44 V versus the SCE. The peak currents, corrected for the residual current, for a set of standard solutions are shown in the following table. ip (µA) [As(III)] M 1.0 x 10-6 0.298 3.0 x 10-6 0.947 6.0 x 10-6 1.83 9.0 x 10-6 2.72 i. Plot the graph of [As (III)] vs ip and use linear regression to obtain the best fit line for the data obtained ii. What is the calibration curve equation. iii. What is the concentration of As (III) in a sample of water if the peak current under the same conditions is 1.37 µA? b) What is the principle of couloemetry

Appl Of Ms Excel In Analytical Chemistry
2nd Edition
ISBN:9781285686691
Author:Crouch
Publisher:Crouch
Chapter11: Dynamic Electrochemistry
Section: Chapter Questions
Problem 10P
icon
Related questions
Question
100%
Question Four
a) The concentration of As(III) in water can be determined by differential pulse polarography in
1 M HCI. The initial potential is set to -0.1 V versus the SCE, and is scanned toward more
negative potentials at a rate of 5 mV/s. Reduction of As(III) to As(0) occurs at a potential of
approximately -0.44 V versus the SCE. The peak currents, corrected for the residual current,
for a set of standard solutions are shown in the following table.
[As(III)] M
1.0 x 10-6
ip (μA)
0.298
3.0 x 10-6
0.947
6.0 x 10-6
1.83
9.0 x 10-6
2.72
i.
Plot the graph of [As (III)] vs ip and use linear regression to obtain the best fit line for the
data obtained
ii.
What is the calibration curve equation.
iii.
What is the concentration of As (III) in a sample of water if the peak current under the
same conditions is 1.37 µA?
b) What is the principle of couloemetry
Transcribed Image Text:Question Four a) The concentration of As(III) in water can be determined by differential pulse polarography in 1 M HCI. The initial potential is set to -0.1 V versus the SCE, and is scanned toward more negative potentials at a rate of 5 mV/s. Reduction of As(III) to As(0) occurs at a potential of approximately -0.44 V versus the SCE. The peak currents, corrected for the residual current, for a set of standard solutions are shown in the following table. [As(III)] M 1.0 x 10-6 ip (μA) 0.298 3.0 x 10-6 0.947 6.0 x 10-6 1.83 9.0 x 10-6 2.72 i. Plot the graph of [As (III)] vs ip and use linear regression to obtain the best fit line for the data obtained ii. What is the calibration curve equation. iii. What is the concentration of As (III) in a sample of water if the peak current under the same conditions is 1.37 µA? b) What is the principle of couloemetry
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Electroanalytical Techniques
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning