Refrigerant-134a enters an adiabatic compressor at 100 kPa and 0 "C with a volumetric flow rate at a pressure of 700 kPa. The power input to the compressor is 35 kW. Using the property tables fe Appendices A-11 to A-13, Determine the following stream properties and report them in the units s requested decimal place: A. The mass flow rate of the refrigerant: kg/s (Report to 3 decimal places, B. The enthalpy of the exit stream: KJ/kg (Report to 2 decimal places, eg: C. The temperature of the exit stream: °C (Report to 1 decimal place, eg: C 100 KPa, 0°C V = 0.3 m³ /s A A R-134 a 35 KW 700 KPa

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Refrigerant-134a enters an adiabatic compressor at 100 kPa and 0 "C with a volumetric flow rate of 0.3 m3/s and leaves
at a pressure of 700 kPa. The power input to the compressor is 35 kW. Using the property tables for R-134a in
Appendices A-11 to A-13, Determine the following stream properties and report them in the units shown and to the
requested decimal place:
A. The mass flow rate of the refrigerant:
kg/s (Report to 3 decimal places, eg: 0.123)
B. The enthalpy of the exit stream:
KJ/kg (Report to 2 decimal places, eg: 0.23)
C. The temperature of the exit stream:
°C (Report to 1 decimal place, eg: 0.1)
100 KPa, 0°C
V = 0.3 m³ /s
%3D
A
A R-134 a
35 KW
700 KPa
Transcribed Image Text:Refrigerant-134a enters an adiabatic compressor at 100 kPa and 0 "C with a volumetric flow rate of 0.3 m3/s and leaves at a pressure of 700 kPa. The power input to the compressor is 35 kW. Using the property tables for R-134a in Appendices A-11 to A-13, Determine the following stream properties and report them in the units shown and to the requested decimal place: A. The mass flow rate of the refrigerant: kg/s (Report to 3 decimal places, eg: 0.123) B. The enthalpy of the exit stream: KJ/kg (Report to 2 decimal places, eg: 0.23) C. The temperature of the exit stream: °C (Report to 1 decimal place, eg: 0.1) 100 KPa, 0°C V = 0.3 m³ /s %3D A A R-134 a 35 KW 700 KPa
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Work and Heat
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY