Situation 21: A square tied column carries a factored load of 2800KN. It will be designed using material strengths fc'=27MPa and fy-345MP.. Assume p-0.02 69. Determine the minimum required dimension of the column. b. 450 mm a. 400 mm c. 500 mm d. 550 mm 70. Determine the number of 625mm vertical bars required. a. 8 bars b. 9 bars c. 10 bars d. 11 bars

Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter9: Composite Construction
Section: Chapter Questions
Problem 9.2.1P: A W1422 acts compositely with a 4-inch-thick floor slab whose effective width b is 90 inches. The...
icon
Related questions
Question
Situation 20: The figure shows a precast plain concrete beam simply supported on a
b --
b
a
File
Home
Insert
D
유 Share
X Cut
span
of 3m.
P Find -
e Copy
Given:
Sac Replace
Paste
* Format Painter
B Concrete unit weight =23.5kN/m³
d.
A Select -
Clipboard
a=200mm
d=200mm
Editing
b=150mm
e=150mm
c=500mm
f=150mm
e
67. Determine the weight of beam
per
meter
a. 2.85 kN/m
b. 2.94 kN/m
c. 3.94 kN/m
d. 4.14 kN/m
ww
C
68. What is the allowable load on the beam if the cracking moment is 27 kN-m
a. 21.15 kN/m
b. 21.06 kN/m
c. 19.86 kN/m
d. 20.06 kN/m
Situation 21: A square tied column carries a factored load of 2800KN. It will be designed using material strengths fc'=27MP
and fy=345MPA. Assume p=0.02
69. Determine the minimum required dimension of the column.
b. 450 mm
a. 400 mm
c. 500 mm
d. 550 mm
70. Determine the number of o25mm vertical bars required.
a. 8 bars
b. 9 bars
c. 10 bars
d. 11 bars
Page 7 of 10
22 of 4146 words
English (United States)
& Accessibility: Investigate
160%
ENG
10:26 am
amazon
w
R888
US
06/03/2022
to
Transcribed Image Text:Situation 20: The figure shows a precast plain concrete beam simply supported on a b -- b a File Home Insert D 유 Share X Cut span of 3m. P Find - e Copy Given: Sac Replace Paste * Format Painter B Concrete unit weight =23.5kN/m³ d. A Select - Clipboard a=200mm d=200mm Editing b=150mm e=150mm c=500mm f=150mm e 67. Determine the weight of beam per meter a. 2.85 kN/m b. 2.94 kN/m c. 3.94 kN/m d. 4.14 kN/m ww C 68. What is the allowable load on the beam if the cracking moment is 27 kN-m a. 21.15 kN/m b. 21.06 kN/m c. 19.86 kN/m d. 20.06 kN/m Situation 21: A square tied column carries a factored load of 2800KN. It will be designed using material strengths fc'=27MP and fy=345MPA. Assume p=0.02 69. Determine the minimum required dimension of the column. b. 450 mm a. 400 mm c. 500 mm d. 550 mm 70. Determine the number of o25mm vertical bars required. a. 8 bars b. 9 bars c. 10 bars d. 11 bars Page 7 of 10 22 of 4146 words English (United States) & Accessibility: Investigate 160% ENG 10:26 am amazon w R888 US 06/03/2022 to
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Arches
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Steel Design (Activate Learning with these NEW ti…
Steel Design (Activate Learning with these NEW ti…
Civil Engineering
ISBN:
9781337094740
Author:
Segui, William T.
Publisher:
Cengage Learning