Source: Source 1: Ean = 12020° v; Epn = 1202 – 120° v; Een = 1204120° v (grounded neutral) Zan = Zbn = Zen = 0.1 + j1.5 N %3D %3D %3D Line Impedance: Line 2: Zine a = 1+ j2 N; Ziine b = 1 – j2 N; Zine c = 0 + j2.2361 N Load Impedance: Load 2a: Zab = 40 + j30 N; Zpc = 40 – j30 N; Zca = 50 + j0 N %3D %3D Fault Location: Fault Location 1: Source Side 30 Source Zine 3 Load Types of Faults to be Considered, assuming worst case scenario (Z, = 0): SLGF (line a grounded), LLF (lines a & b connected), 1LO (line a open) Faults not considered: DLGF, TPF, 2LO Find: Under Unbalanced Condition With Faults: b. Load Line Voltages (Vab, Vbc, Vca); c. Load Power Profile (Pr, QT,St,pfr); d. The Fault Current (If)

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Source:
Ean = 12020° v; Epn = 1202 – 120° v; Een = 1202120° v (grounded neutral)
Zan = Zpn = Zen = 0.1 + j1.5 N
Source 1:
%3D
Line Impedance:
Line 2: Zine a = 1+j2 N; Ziine b = 1– j2 N; Zine c = 0 + j2.2361 N
Load Impedance:
Load 2a: Zab = 40 + j30 N; Zpc = 40 – j30 N; Zca = 50 + j0 N
%3D
%3D
%3D
Fault Location:
Fault Location 1: Source Side
30 Source
Zine
30 Load
Types of Faults to be Considered, assuming worst case scenario (Z, = 0):
SLGF (line a grounded), LLF (lines a & b connected), 1LO (line a open)
Faults not considered: DLGF, TPF, 2LO
Find:
Under Unbalanced Condition With Faults:
b. Load Line Voltages (Vab, Vpc, Vca);
c. Load Power Profile (PT, QT,St,pfr);
d. The Fault Current (I;)
Transcribed Image Text:Source: Ean = 12020° v; Epn = 1202 – 120° v; Een = 1202120° v (grounded neutral) Zan = Zpn = Zen = 0.1 + j1.5 N Source 1: %3D Line Impedance: Line 2: Zine a = 1+j2 N; Ziine b = 1– j2 N; Zine c = 0 + j2.2361 N Load Impedance: Load 2a: Zab = 40 + j30 N; Zpc = 40 – j30 N; Zca = 50 + j0 N %3D %3D %3D Fault Location: Fault Location 1: Source Side 30 Source Zine 30 Load Types of Faults to be Considered, assuming worst case scenario (Z, = 0): SLGF (line a grounded), LLF (lines a & b connected), 1LO (line a open) Faults not considered: DLGF, TPF, 2LO Find: Under Unbalanced Condition With Faults: b. Load Line Voltages (Vab, Vpc, Vca); c. Load Power Profile (PT, QT,St,pfr); d. The Fault Current (I;)
Expert Solution
steps

Step by step

Solved in 9 steps with 9 images

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,