The air supply to a fermenter was turned off for a short period of time and then restarted. A value for C* of 7.3 mg/l of has been determined for the operating conditions. Use the tabulated measurements of dissolved oxygen (DO) values in the following table to estimate the oxygen uptake rate and kla in this system. Time (min) DO (mg/l) -1 3.3 Air off 3.3 1 2.4 2 1.3 3 0.3 4 0.1 0.0 Air on 0.0 7 0.3 1.0 9. 1.6 10 2.0 11 2.4 12 2.7 13 2.9 14 3.0 15 3.1 16 3.2 17 3.2

Biomedical Instrumentation Systems
1st Edition
ISBN:9781133478294
Author:Chatterjee
Publisher:Chatterjee
Chapter11: Instrumentation In Respiration
Section: Chapter Questions
Problem 4P
icon
Related questions
Question
The air supply to a fermenter was turned off for a
short period of time and then restarted. A value for C*
of 7.3 mg/l of has been determined for the operating
conditions. Use the tabulated measurements of
dissolved oxygen (DO) values in the following table to
estimate the oxygen uptake rate and kla in this system.
Time (min)
DO (mg/l)
-1
3.3
Air off
3.3
1
2.4
2
1.3
3
0.3
4
0.1
0.0
Air on
0.0
7
0.3
1.0
9.
1.6
10
2.0
11
2.4
12
2.7
13
2.9
14
3.0
15
3.1
16
3.2
17
3.2
Transcribed Image Text:The air supply to a fermenter was turned off for a short period of time and then restarted. A value for C* of 7.3 mg/l of has been determined for the operating conditions. Use the tabulated measurements of dissolved oxygen (DO) values in the following table to estimate the oxygen uptake rate and kla in this system. Time (min) DO (mg/l) -1 3.3 Air off 3.3 1 2.4 2 1.3 3 0.3 4 0.1 0.0 Air on 0.0 7 0.3 1.0 9. 1.6 10 2.0 11 2.4 12 2.7 13 2.9 14 3.0 15 3.1 16 3.2 17 3.2
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Air pollution
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, biology and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Biomedical Instrumentation Systems
Biomedical Instrumentation Systems
Chemistry
ISBN:
9781133478294
Author:
Chatterjee
Publisher:
Cengage
Human Physiology: From Cells to Systems (MindTap …
Human Physiology: From Cells to Systems (MindTap …
Biology
ISBN:
9781285866932
Author:
Lauralee Sherwood
Publisher:
Cengage Learning
Curren'S Math For Meds: Dosages & Sol
Curren'S Math For Meds: Dosages & Sol
Nursing
ISBN:
9781305143531
Author:
CURREN
Publisher:
Cengage
Cardiopulmonary Anatomy & Physiology
Cardiopulmonary Anatomy & Physiology
Biology
ISBN:
9781337794909
Author:
Des Jardins, Terry.
Publisher:
Cengage Learning,
Basic Clinical Laboratory Techniques 6E
Basic Clinical Laboratory Techniques 6E
Biology
ISBN:
9781133893943
Author:
ESTRIDGE
Publisher:
Cengage
Aquaculture Science
Aquaculture Science
Biology
ISBN:
9781133558347
Author:
Parker
Publisher:
Cengage