The efficiency of a 20 kVA 15.4 / 0.4 kV three-phase power transformer is 82,4% for a load with unity power factor at rated power. Relative short circuit voltage% Uk = 30.0 and relative no-load current% I0 = 30. Since the transformer (Star-delta) is connected; Note: In 3-phase electrical machines, the current-voltage information given on the label is always line values. Phase valueWhen given, it must be specified separately. Therefore, all current-voltage information given in the question are line values. 1-) Draw the primary reduced equivalent circuit. 2-) What is the power value measured in the short circuit test of this transformer? 3-) What is the iron loss value of this transformer ?
The efficiency of a 20 kVA 15.4 / 0.4 kV three-phase power transformer is 82,4% for a load with unity power factor at rated power. Relative short circuit voltage% Uk = 30.0 and relative no-load current% I0 = 30. Since the transformer (Star-delta) is connected; Note: In 3-phase electrical machines, the current-voltage information given on the label is always line values. Phase valueWhen given, it must be specified separately. Therefore, all current-voltage information given in the question are line values. 1-) Draw the primary reduced equivalent circuit. 2-) What is the power value measured in the short circuit test of this transformer? 3-) What is the iron loss value of this transformer ?
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.64P: The per-unit equivalent circuit of two transformers Ta and Tb connected in parallel, with the same...
Related questions
Question
The efficiency of a 20 kVA 15.4 / 0.4 kV three-phase power transformer is 82,4% for a load with unity power factor at rated power.
Relative short circuit voltage% Uk = 30.0 and relative no-load current% I0 = 30.
Since the transformer (Star-delta) is connected;
Note: In 3-phase electrical machines, the current-voltage information given on the label is always line values. Phase valueWhen given, it must be specified separately. Therefore, all current-voltage information given in the question are line values.
1-) Draw the primary reduced equivalent circuit.
2-) What is the power value measured in the short circuit test of this transformer?
3-) What is the iron loss value of this transformer ?
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 3 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning