The pump is mounted 2.0 m above the water level. There is a 50 mm PVC pipe connected to the suction side of the pump, and a 40 mm PVC pipe connected to the discharge side. The total length of pipe on the suction side is 8 m, and there is a strainer (K = 20), a non-return valve, a 90° elbow and a fully open gate ball valve in the suction line. Another fully open gate valve, and two 90° elbows are mounted in the discharge line. The total length of the discharge line is 60 m, and the discharge pipe outlet is 4 m above the pump. You may assume a water temperature of 25 °C. Determine: (a) The flow rate through the s
A pump, for which the characteristic curve is shown below, is used to pump water from a canal into a dam. The pump is mounted 2.0 m above the water level. There is a 50 mm PVC pipe connected to the suction side of the pump, and a 40 mm PVC pipe connected to the discharge side. The total length of pipe on the suction side is 8 m, and there is a strainer (K = 20), a non-return valve, a 90° elbow and a fully open gate ball valve in the suction line. Another fully open gate valve, and two 90° elbows are mounted in the discharge line. The total length of the discharge line is 60 m, and the discharge pipe outlet is 4 m above the pump. You may assume a water temperature of 25 °C. Determine:
(a) The flow rate through the system
(b) The required fluid power
(c) The efficiency of the pump
(d) Whether the pump will cavitate or not.
Step by step
Solved in 4 steps with 4 images