The speed of a 20-HP, 300V, and 1800 rpm separately excited DC motor is controlled by a three-phase fullconverter drive. The field converter is also controlled by a three-phase full-converter and is set for maximum possible output voltage. The ac input is a three-phase, Y- connected 208V, 60 Hz supply. Let Ra = 0.25 ?, Rf = 245 ?, kv = 1.2 V/A-rad/sec. Neglect friction and assume armature and field currents to be constant. Determine the values of: Ca if the motor delivers rated power at the rated speed, (a) No-load speed if la at no-load is 10% of the (b) rated value, (c) Speed regulation, VR = (VNo-Load - VFull-Load )/ VNo-Load

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
The speed of a 20-HP, 300V, and 1800 rpm
separately excited DC motor is controlled by a
three-phase fullconverter drive. The field
converter is also controlled by a three-phase
full-converter and is set for maximum possible
output voltage. The ac input is a three-phase, Y-
connected 208V, 60 Hz supply. Let Ra = 0.25 ?,
Rf = 245 ?, kv = 1.2 V/A-rad/sec. Neglect friction
%3D
and assume armature and field currents to be
constant.
Determine the values of:
Ca if the motor delivers rated power at the
rated speed,
(a)
No-load speed if la at no-load is 10% of the
(b)
rated value,
(c)
Speed regulation, VR = (VNo-Load –
%3D
VFull-Load) / VNo-Load
Transcribed Image Text:The speed of a 20-HP, 300V, and 1800 rpm separately excited DC motor is controlled by a three-phase fullconverter drive. The field converter is also controlled by a three-phase full-converter and is set for maximum possible output voltage. The ac input is a three-phase, Y- connected 208V, 60 Hz supply. Let Ra = 0.25 ?, Rf = 245 ?, kv = 1.2 V/A-rad/sec. Neglect friction %3D and assume armature and field currents to be constant. Determine the values of: Ca if the motor delivers rated power at the rated speed, (a) No-load speed if la at no-load is 10% of the (b) rated value, (c) Speed regulation, VR = (VNo-Load – %3D VFull-Load) / VNo-Load
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,