This term refers to the number of times a wire revolves around the armature core. turn revolution This is the rotating part of the generator or motor. rotor stator Which of these is NOT a part of a DC generator? stator slip rings commutator brushes
Q: 3. A 10kW, 4-pole lap wound, de shunt generator has a useful flux per pole of 0.075 Wb. The armature…
A: 3) A dc shunt generator with 4 - pole lap wound and output power = 10 kw To calculate the terminal…
Q: 250 V, 4 pole wave wound shunt motor has 650 conductors on its armature. It has armature and shunt…
A:
Q: C3 (3). The armature of a 4 pole DC shunt generator has 28 slots and is lap wound with 10 conductors…
A: (a) Draw the circuit diagram for the dc shunt generator.
Q: Q4 (a) Name the features of FIVE (5) types of generators with description. (b) Explain how the…
A: In the question Describe the types of the DC generator We are describe according the connection of…
Q: Urgent need in 5 mins please :( * A triplex lap wound armature has 300 turns and takes 125 A of…
A:
Q: A four-pole shunt motor has an armature with a total of 282 conductors. If each pole face has an…
A: Number of poles = 4 Number of conductors = 282 Pole face area = 25 square inches. Flux density =…
Q: P-1).. Which of the following determine the amount of torque produced by a single-phase split-phase…
A: In single phase split phase motor the amount of torque produced is depend on the phase angle…
Q: A separately excited generator has lap-wound armature with 12 slots and 5 turns per coil. It is…
A:
Q: 4 pole , lap wound dc shunt generator has a useful flux per pole of 0.07 Wb. The armature winding…
A: In this question DC shunt generator is given....We have to find out it's terminal voltage...
Q: A 240 V d.c. shunt motor runs at 700 r.p.m. ,takes 12kW. Find resistance to be added to the field…
A:
Q: A 4-pole, 240V, wave connected shunt motor running at 1000 rpm and drawing armature and field…
A: SOLUTION- Given, P =4 A = 2 (Wave connected) N = 1000 rpm Z= 540 Ia = 50A If = 1 A Eb=…
Q: A 200 V, 6 pole, lap connected long shunt compound wound d.c. The resistances of the armature series…
A:
Q: rpm (full load), 300 A (full load), 0.0935 armature resistance. The motor efficiency is 90 %.…
A: Since you have asked multiple questions in a single request, we will be answering only the 1st…
Q: Question 9 What factors affect the torque of a dc motor? (Select all that applies) A) Number of…
A: As per our company guidelines we are supposed to answer only first question kindly repost other…
Q: A 4-pole, 900 r.p.m. d.c. generator has a terminal voltage of 220 V and an induced voltage of 240 V…
A: For the given 4-Pole Dc generator Eg = 240 V Vt= 220V N=900 Ra= 0.2 ohms Flux = 10 m Wb Armature…
Q: A 4 pole, (01*10)V, DC shunt motor operates on a load current (1*10)A, having wave connected…
A: Given: V= 10 IL= 10 A Z=200 flux per pole = 25 mwb Rsh=1 ohm Ra= 0.15 ohm
Q: A 4 pole D.C. Shunt generator with armature and shunt field resistance of 1Ω, 100Ω has 378 wave…
A:
Q: The armature of a 4-pole, 136 slots shunt generator is lap wound with four conductors per slot. The…
A:
Q: L1. It common practice to provide access to the interpole windings on machines designed to be used…
A: Inter pole windings are Windings used in DC motors
Q: Ea (V) MAGNETIZATION CURVE 225 220 V series DC motor has an armature resistance of 0.04 Q. The motor…
A:
Q: A 8 pole, DC generator has a simplex wave wound armature containing 32 coils of 6 turns each. Its…
A: Given: A DC generator with following specifications Number of poles, P=8 Number of coils is 32 Turns…
Q: iA 4-pole, DC machine has 144 slot in the armature with 2 coil- sides per slot, each coil has 2…
A: In this question we need to find a induced emf of DC machine across armature and across each…
Q: A 4-pole, 900 r.p.m. d.c. generator has a terminal voltage of 220 V and an induced voltage of 240 V…
A: The solution is attached below.
Q: A 4 pole, 230 volt, lap wound d.c. motor has 545 conductors. With a speed of 1200 RPM, the flux per…
A:
Q: 2- A simple wave wound de shunt motor has the following data: Armature resistance =0.1 ohm Shunt…
A: Given data: Ra=0.1 Ω Rsh=100 Ω P=2 Z=400 Vs=400 V N=3000 rpm Is=104 A Wave winding, A = 2…
Q: Squirrel-cage asynchronous motor, which has never been used before, as a generator in its first use…
A: A squirrel-cage rotor is the rotating part of the common squirrel-cage induction motor. It consists…
Q: (ii) The armature of a 14 pole DC shunt generator has 60 slots and is lap wound with 13 conductors…
A: The solution is attached below for given shunt generator.
Q: four-pole shunt connected generator has a lap connected armature with 728 conductors. The fluxper…
A:
Q: A four-pole DC generator supplies an armature current of 100A at full load. It has wave wound…
A: The solution can be achieved as follows.
Q: Total number of conductors on the armature (ii) voltage induced by the generator (in Volts)
A:
Q: QUESTION FOUR 4. A 12 kW, six-pole DC generator develops an emf of 240 at 1500 rpm. The armature has…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Q: A belt-driven 150 kW shunt wound DC generator is running at 500 rpm and is supplying full load to a…
A:
Q: The terminal voltage of a D.C. shunt generator drops on load because of all of the following reasons…
A: The terminal voltage of a D.C shunt generator drops on load due to decrease in generated voltage or…
Q: 10kW, 4-pole lap wound, dc shunt generator has a useful flux per pole of 0.075 Wb. The armature…
A: In this question we will find terminal voltage of dc shunt generator...
Q: The armature of a 12 pole DC shunt generator has 50 slots and is wave wound with 12 conductors per…
A: Given: Number of poles P = 12 Number of slots = 50 Speed N = 625 rpm Terminal voltage = 300V…
Q: The armature of a 4 pole, 128 slots shunt generator is lap wound with 4 conductor per slot. The flux…
A: The detailed solution is as follows.
Q: C3 (iii). The armature of a 4 pole DC shunt generator has 27 slots and is wave wound with 12…
A:
Q: A6-pole, 24 KW, 120 V, DC machine has a Duplex LAP-woundarmature which has 72 coils with 10 turns…
A: Given data, P=4VT=120 VPout=21.5 kW
Q: The armature of a 4-pole, 130 slots shunt generator is lap wound with four conductors per slot. The…
A:
Q: 2- A simple wave wound de shunt motor has the following data: Armature resistance =0.1 ohm Shunt…
A:
Q: Q2)A train is driven by a DC machine with independent electrical excitation. At a speed of 1500 rpm,…
A: We are authorized to answer three sub-parts at a time, since you have not mentioned which part you…
Q: Q2- A 6 pole lap connected DC generator has 480 turns ,the resistance of each turn is 0.03 Q, the…
A: Generated EMFflux×speed×conductors60×polesparallel paths. Terminal voltage=genarated EMF-drop in…
Q: Q 4. An 8-pole DC generator has 400 armature conductors and a useful flux of 0.05 Wb. What will be…
A:
Q: The armature of a 14 pole DC shunt generator has 60 slots and is lap wound with 13 conductors per…
A:
Q: The magnetization reversal in the armature core of the DC machine causes the O Windage Loss O…
A:
Q: C3 (iii). The armature of a 4 pole DC shunt generator has 28 slots and is wave wound with 8…
A: Given that number of poles, P=4. Number of slots, S=28. Number of conductors per slots, Z/S=8 Number…
Q: A 4 pole, 220V dc shunt motor takes 32A from the supply mains and develops a power of 5.6KW in its…
A:
Q: A 6-pole, 1750 rpm shunt motor has a lap wound armature with 580 conductors. If the flux per pole is…
A:
Q: The magnetization reversal in the armature core c the DC machine causes the O Windage Loss O Eddy…
A: 1)Hysteresis loss is the loss that is obtained because of magnetic reversal of dipoles in the core…
Q: When a DC generator is supplying power to a load, _____ is developed in the armature that has _____…
A: The solution is given below
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- A 10kW, 4-pole lap wound, dc shunt generator has a useful flux per pole of0.075 Wb. The armature consist a total of 500 conductors. Calculate theterminal voltage when running at 900 rpm if the armature current and shuntfield resistances are 0.5 ohms and 50 ohms.The following information is given for a DC generator terminal volts = 480; rpm = 1000; number of slots = 130; number of commutator segments = 390; coil pitch = slot 1 to slot 22; type of winding = simplex lap; air gap flux density = 57,000 maxwells per sq. in.; pole-face area = 5.75 x 6 in. What is the number of poles?(b) Flux per pole? and (c) number of turns per armature winding element ?What is the voltage regulation of a DC generator proportional to?
- 2) the armature windings of a 12-pole DC machine are composed of 72 coils with 10 windings, and the windings are 5the layered wave is yellowish. The Rotor speed is 1000 rpm and the flux value per pole is 25mWb.Resistance of Armature windings, commutation windings and compensation windings is 70mΩ, 10mΩ and5mω. (a) the number of current paths in the machine, (b) the total number of conductors in Armature windings, (c) armature coefficient (constant)A 6 pole generator with wave wound armature has 58 slots each having 24 conductors. The flux per pole is 0.01 Wb. (i) At what speed must the armature rotate to give an induced EMF of 235V is? (ii) What will be the voltage developed, if the winding is lap connected and the armature rotates at the same speed is?10. The following information is given for a DC generatorL terminal volts = 480; rpm = 1000; number of slots = 130; number of commutator segments = 390; coil pitch = slot 1 to slot 22; type of winding = simplex lap; air gap flux density = 57,000 maxwells per sq. in.; pole-face area = 5.75 x 6 in. Calculate the number of turns per armature-winding element.
- A 2 pole wave wound dc shunt generator runs at a speed of 750 rpm, has an armature and shunt field resistance of 0.9 Q and 280 Q respectively. The armature has 880 conductors and flux per pole is 0.115 Weber. If the lamp load connected has a resistance of 30 Q, determine (i) Generated EMF, (ii) Total Resistance, (iii) Armature Current, (iv) Terminal Voltage.A four-pole shunt motor has an armature with a total of 282 conductors. If each pole face has an area of 25 sq. in. and the flux density is 50,000 lines per square inch, calculate the horsepower that will be developed by the motor for a speed of 1,450 rpm?Explain in detail why large variable resistance connected in series with armaturewinding at starting of permanent magnetic D.C. motors
- An 8 pole DC shunt generator with wave winding has 4800 conductor with 20 turns and average per pole flux is 20 mwb and armature current and armature resistance is 20 A and 0.5 ohm respectively find? (i) Induced emf (ii) Terminal goltagethe lap wound armature of a six pole generator has600 active conductors. The speed is 1000rpm. The area of each pole face is 100 sq. in. and the average air gap flux density under the pole face is 8000 gauss. Calculate the emf between the positive and negative brushes.A four-pole shunt motor has an armature with a total of 282 conductors. If each pole face has an area of 25 in² and the flux density is 50,000 lines per sq. inch. Calculate the power developed by the motor in horsepower for an armature current of 85 A and a speed of 1420 rpm. (Assume a wave-connected armature winding).