What causes the overload of a starter to open and disable the power circuit?
Q: What is the motor used for pumping water in domestic application? Why?
A: Depending on the size of pump, there can be either three phase induction motor or single phase…
Q: why is the power not interrupted when the motor makes the transition from start to run?
A: 3-phase motors are commonly self-starting while the dc motors are not self-starting. To run the…
Q: What determines the type of motor enclosure selected for a particular application?
A: The factors which determine the type of motor enclosure selected for a particular application are…
Q: Differentiate between the Manual over Magnetic DC Motor Controller
A:
Q: If a timing relay fails to cut in the run starter, what percentage of the full load current can the…
A: Starter is used to protect and control the very high starting current absorb by the motor during the…
Q: In developing line or wiring disgrams,in which lines should the overload relays be place for three -…
A: On developing the line or wiring diagrams, in which lines should the overload relays be place for…
Q: At standstill condition, the back emf is zero, so the motor can be safely turned ON without a…
A:
Q: The control circuit is connected to which lines for a three-phase motor starter?
A: The circuit diagram for the three-phase motor starters is given below:
Q: Explain all the types of distance protection relays?
A:
Q: When using a coil that is not designed for continuous duty, what may happen if a resistor is not…
A: A coil that is not designed for continuous duty, the coil is energized for a short time. This short…
Q: Where is the speed control for a range hood fan located
A:
Q: For the Starting Up the Power Station Simulator Why are certain operations blocked by isolators
A:
Q: How can you reduce the amount of voltage applied to the motor during inching?
A:
Q: Why rheostat is kept in the minimum value at starting condition?
A: At the time of starting of DC shunt motor the armature resistance is kept at maximum position to…
Q: What is the function of the double contact pushbutton in a Start-Stop-Jog motor control circuit?
A: Double contact pushbutton is used in the Start-Stop-Jog motor control circuit, its functions are as…
Q: What is plugging type braking?
A: Braking is of two type, one is for mechanical system and other is for electrical system. Hence,…
Q: Does the Indoor Fan Motor stop when the control fuses faulty?
A: In this question we will see about control fuse importance...
Q: When can full-voltage starting be used?
A:
Q: What does affect to the system if the control fuse faulty (blown)?
A: The explanation is as follows.
Q: Why do we connect stop pushbuttons in series in a two - station motor control?
A: Control circuit of two station motor control is as,
Q: Why starters are used for DC motors. * Your answer
A: Starter is a device which is used to start DC motors.
Q: What happened to the dc if it runs without any starter?
A: What happened to the dc if it runs without any starter?
Q: Explain the working of induction cup relay with the help of diagram.Explain all the parts in detail…
A:
Q: The control circuit is connected to which lines for a three phase motor starters?
A: direct on line starter (abbreviated as DOL)or across the line starter is a method for starting a 3…
Q: Why do you think some motor control circuit utilizes single voltage sources for control and power…
A: Types of Motor control based on power supply Three power supply Two wire supply Types of…
Q: What is starter ? Function of starter?
A: A motor starters main job is to start and stop the motor to which it is attached. These…
Q: Assume a motor is running. What happens when the stop button is pressed and then the start button is…
A: Consider that a motor is in a running position. Find what will happen when the stop button is…
Q: Large motor should be connected directly across the line on start up
A: To explain that whether large motor should be connected directly across the line on start up.
Q: If the speed of the driving motor falls due to loading what will be the effects?
A: A motor is a device which convert electrical energy into mechanical energy.The speed (RPM)of a motor…
Q: For a start-stop push button control circuit that has been reconnected so that the start button is…
A:
Q: A 460VAC rated, 60 Hz, 125-Hp Three-phase induction type motor is to be connected for…
A:
Q: The starter must never operate for more than sixty seconds at a time and should rest for two minutes…
A: The starter must never operate for more than sixty seconds at a time and should rest for two minutes…
Q: list the probable causes if the armature does not release after the magnetic starter is…
A: For the control of 3-phase motors, the magnetic starter allows separation of the control circuit…
Q: Can the Manual Motor Starter be used alone or only with a contactor?
A: Manual motor starter is used to switch motors ON/OFF manually and mainly provide electromechanical…
Q: Can I use the Manual Motor Starter on a single phase motor? Why?
A: MANUAL MOTOR STARTER Manual motor starters are devices that use manual or automatic switches to…
Q: Worn armature bearing can result in higher than normal starter cranking current draw ? True or false
A: The above statement is true.
Q: motor nameplate reads 230/460 volts, 30-15 amperes. When connected to a 460-volt supply, how much…
A: Nameplate rating of motor contains many things like Voltage, frequency, phase, current, power…
Q: Assume the motor is running. What happens when the stop button is pressed and then the start button…
A: While the motor is running and if the stop and start button are pressed alternatively. Their effect…
Q: overload heater element
A: If an overload heater element is not installed in a two-pole manual starter then the Motor will not…
Q: Why do we use pushbutton type switches for controlling the motor circuit?
A: Push buttons are momentary contacts available as either normally open(NO) or normally closed(NC)…
Q: List 3 hazards when constructing (working) with a homemade D.C motor and how it can be managed?
A: List of some hazards when constructing (working) with a homemade D.C motor: Do not use in a…
Q: our Answers may be presented through Discussions, Drawings/Figures/Diagrams, Reference to NEC/PEC…
A: Given data, The conductor is connected to the three motors. Motor 1=50 hp Motor 2 = 40hp Motor 3 =…
Q: When selecting motor overload protection devices from where is the full load ampere rating taken?
A: This question is from "Electrical Machine". Under which we are going to study about the overload…
Q: One reason for the use of a reduced voltage starter would be to reduce the high starting current…
A: There are many ways by which we can reduce the high starting currents in motor
Q: A selector switch and two - wire pilot device cannot be used to control a large motor directly but…
A: Selector switch and two-wire pilot devices are only used to control lower rating motors.
What causes the overload of a starter to open and disable the power circuit?
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- If a motor starter is installed according to directions but will not start, what is a common cause for the failure to start?One reason for the use of a reduced voltage starter would be to reduce the high starting current drawn by the motor. True or false?Why should the motor be run for a period of time following checkout?
- what must be done to prevent excessive motor current?A selector switch and two - wire pilot device cannot be used to control a large motor directly but rather must be connected to a magnetic starter. Why this is true.?If the contacts on a manual starter cannot be closed immediately after a motor overload has tripped them open, what is the probable reason?