Wind blows on the side of a fully enclosed hospital located on open flat terrain where V = 120 mi/h. Windward wall has a height of 30 ft. The roof is flat. Use the table below to determine Kz for the formula for the design wind pressure according to the ASCE 7-10 Standard.     Velocity Pressure Exposure Coefficient for Terrain with Low-Lying Obstructions z(ft) z(m) Kz 0-15 0-4.6 0.85 20 6.1 0.90 25 7.6 0.94 30 9.1 0.98 40 12.2 1.04 50 15.2 1.09   A) Determine the design wind pressure acting on the windward wall of the building at the height of 25 ft above the ground for a positive internal building pressure using the ASCE 7-10 Specifications. p25= ______ psf   B) Determine the design wind pressure acting on the windward wall of the building at the height of 30 ft above the ground for a positive internal building pressure using the ASCE 7-10 Specifications. p30= ______ psf   C) Determine the design wind pressure acting on the windward wall of the building at the height of 0-15 ft above the ground for a negative internal building pressure using the ASCE 7-10 Specifications. p0-15= ______ psf

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

Wind blows on the side of a fully enclosed hospital located on open flat terrain where V = 120 mi/h. Windward wall has a height of 30 ft. The roof is flat. Use the table below to determine Kz for the formula for the design wind pressure according to the ASCE 7-10 Standard.

 

 
Velocity Pressure Exposure Coefficient for Terrain with Low-Lying Obstructions
z(ft) z(m) Kz
0-15 0-4.6 0.85
20 6.1 0.90
25 7.6 0.94
30 9.1 0.98
40 12.2 1.04
50 15.2 1.09

 

A) Determine the design wind pressure acting on the windward wall of the building at the height of 25 ft above the ground for a positive internal building pressure using the ASCE 7-10 Specifications.

p25= ______ psf

 

B) Determine the design wind pressure acting on the windward wall of the building at the height of 30 ft above the ground for a positive internal building pressure using the ASCE 7-10 Specifications.

p30= ______ psf

 

C) Determine the design wind pressure acting on the windward wall of the building at the height of 0-15 ft above the ground for a negative internal building pressure using the ASCE 7-10 Specifications.

p0-15= ______ psf

 

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning