You have been hired as a consultation engineer for a manufacturing company to test and diagnose a low voltage and overheating problem with a single phase transformer utilized to supply their single phase loads. The company technicians informed you that the transformer has a solid nickel core, insulated aluminum windings and its nameplate ratings are 100 kVA, 6600/230 V, 60 Hz (a) Given that the transformer is delivering 80% full load at 0.9 power factor lag calculate: 1) the output voltage assuming the input voltage is maintained at 6600V n the voltage regulation at this load iIm) the efficiency at this load

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.17P: The transformer of Problem 3.16 is supplying a rated load of 50 kVA at a rated secondary voltage of...
icon
Related questions
Question
You have been hired as a consultation engineer for a manufacturing company to test and
diagnose a low voltage and overheating problem with a single phase transformer utilized to
supply their single phase loads.
The company technicians informed you that the transfomer has a solid nickel core, insulated
ahumimum windings and its nameplate ratings are 100 kVA, 6600/230 V, 60 Hz.
(a) Given that the transformer is delivering 80% full load at 0.9 power factor lag, calculate:
i) the output voltage assuming the input voltage is maintained at 6600V
ii) the voltage regulation at this load
iii) the efficiency at this load
Transcribed Image Text:You have been hired as a consultation engineer for a manufacturing company to test and diagnose a low voltage and overheating problem with a single phase transformer utilized to supply their single phase loads. The company technicians informed you that the transfomer has a solid nickel core, insulated ahumimum windings and its nameplate ratings are 100 kVA, 6600/230 V, 60 Hz. (a) Given that the transformer is delivering 80% full load at 0.9 power factor lag, calculate: i) the output voltage assuming the input voltage is maintained at 6600V ii) the voltage regulation at this load iii) the efficiency at this load
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning