1. Cotabato Light and Power Company supplies two-single phase transformers at San Pablo Area banked in open delta. If each transformer is rated 75-kVA capacity, what is the maximum 3-phase load in kilowatts that the bank can carry without suffering overload considering that the load has a lagging power factor of 0.80.
Q: True or False? Consider a 3 phase transformer with same line to line voltage ratio. The delta…
A: Delta to Delta transformer: The primary phase current is,I1=13IL1The secondary phase currennt…
Q: Consider Figure 1 of the text. For an ideal phase-shifting transformer, the impedance is unchanged…
A: Referring to the given hints, the impedance of the secondary side seen from the primary side:
Q: a) What is the minimum required transformer rating in kVA? b) By what percentage could the required…
A: It is given that:
Q: A 250 MVA, 11/400 kV 3-phase power transformer has a leakage reactance of 0.05 pu on the base of 250…
A: Given values are - Rating=250MVAVLVH=11400Xpu=0.05
Q: Example 1: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results:…
A:
Q: 1) What are the advantages and disadvantages of 3- phase transformers over 3 single-phase bank of…
A: 1.) The advantages of 3- phase transformers over 3 single-phase bank of transformers are as follows:…
Q: 2. If a 250MVA,11/400 KV, Three –Phase power Transformer has leakage reactance of 0.05 pu on the…
A:
Q: Two 70 kW single-phase transformers are connected in parallel. The impedances of the first and…
A:
Q: 2. A 3-phase, 6,600/415-V, 2,000-kVA transformer has a per unit resistance of 0.02 and a per unit…
A:
Q: These transformers normally mounted on power poles or installed inside a large building near…
A: 1) Transformer is an electrical machine which step up step down the voltage without change in…
Q: A 3-phase transformer bank will be created with three 600 VA, 120/240 v one-phase transformers.…
A: 3 single phase transformers are connected to form a 3-ph. transformer. Rating of single phase…
Q: The diagram for a single phase 60 MVA transformer is given below. Convert it to a Step-down…
A: Design the step down autotransformer Single phase transformer have 60MVA 50/100kV Find the all…
Q: Consider that three single-phase transformers are connected as Delta in the primary and Wye in the…
A:
Q: The meaning of a star-delta connected transformer in a zero sequence network of a 3-Phase power…
A: This solution discusses about the zero sequence network of a transformer.
Q: In a 100 kVA, 1100/220 V, 50 Hz single-phase transformer with 2000 turns on the high-voltage side,…
A: The solution is given below.
Q: You have been tasked with comparing the transformer from ABC Ltd. with a 65 kVA, 11000 V/415 V, 50…
A: Given R1=10 ΩR2 =0.05 ΩX1 =20 ΩX2 =0.12 ΩXm =20 kΩRc = 200 kΩS =65 kVApower factor =0.8V2V1=11000415
Q: Derive physically the reason of the phase shift in three phase transformer and show the phase shift…
A: The given problem can be laid down into parts. Firstly, the reason of the phase shift in the three…
Q: 1. Consider a three-phase transformer with a rating of 700 MVA and a secondary voltage of 145 kv.…
A:
Q: Questions:- 1. What happen when the two transformers are operated in parallel having un equal turn's…
A: According to the bartleby's guidelines we have to solve only one question posted by students so…
Q: transformer (A) having a rating of 2000 KVA is connected in parallel with transformer (B) with 4000…
A:
Q: For a conceptual single-phase phase-shifting transformer, the primary voltage leads the secondary…
A: Note: As per our policy, I have attempted the first three subquestions. Given data: E1=E2+308E2=277…
Q: Data from short-circuit and open-circuit tests of a 25-kVA, 6900-230 V, 60 Hz transformer are given…
A:
Q: 4. A 3-phase transformer, ratio 33/6.6-kV, A/Y, 2-MVA has a primary resistance of 89 per phase and a…
A:
Q: = Two 1-ph transformers 6000/400V, the first 200kVA and the other is 350kVA when performing the…
A: TRANSFORMER : A transformer is a passive electrical device that transmits electrical energy from…
Q: Consider a single phase transformer of rating 150 KVA, 3600/360, 50 Hz. Let the series resistance…
A: Formula to calculate voltage required to produce rated current at short circuit is: VSC=V1×ZPUwhere…
Q: 2) 50 kVA, 2300 V / 230 V transformer draws 750 W power and 0.5 A current at rated idle primary…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Q: 9. While conducting short short circuit test in a transformer, which side is short circuited?
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: What is the per unit impedance of a 50 MVA, 13.8 kV, 1% impedance transformer if the base is change…
A:
Q: A three-phase Y-Y transformer is rated at 25 MVA, 13.8-kV:69-kV and has a single-phase equivalent…
A:
Q: 3.6 For a conceptual single-phase phase-shifting transformer, the primary voltage leads the…
A:
Q: 1. (a) The diagram for a single phase 60 MVA transformer is given below. Convert it to a Step-down…
A: Given 2-winding transformer details are V1/V2=50/100 kV.S=60 MVA The input and output currents of…
Q: Three single-phase two-winding transformers, each rated 25 MVA, 54.2/5.42 kV, are connected to form…
A: The explanation is as follows.
Q: Q1: What is the influence of transformer connections in single-phase transformers connected for 3-…
A: According to the Bartleby guidelines “Since you have asked multiple question, we will solve the…
Q: Given three phase fullwave with center tapped transformer with 220 Vac source voltage, determine:…
A: Since you have posted a question with multiple sub-parts, we will solve the first three subparts for…
Q: A single-phase two-winding transformer rated 90 MVA, be connected as an autotransformer rated 80/200…
A:
Q: A generator is connected through a 20 MVA, 13.8/138 kV step up transformer, to a transmission line.…
A: Given- MVA rating of generating station=20 MVA & KVA rating of generating station=13.8 kV MVA…
Q: Example 1: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results:…
A:
Q: Example 22: In a single-phase transformer, the magnitude of leakage reactance is twice that of…
A: Given that magnitude of leakage reactance of transformer is twice that of resistance of primary and…
Q: A 400-MVA, 240-kV/24-KV, three-phase Y-A transformer has an equivalent series impedance of 1.2 + j6…
A: According to the question we have to find the line-to-line voltage at high terminals of the…
Q: A single-phase transformer, working at unity power factor has an efficiency of 90 % at both…
A:
Q: Example 10. A 3300/230 V, 50-kVA, transformer is found to have impedance of 4% and a Cu loss of 1.8%…
A: In this question we will find percentage reactance and ohmic value of resistance , reactance and…
Q: 2. An open delta transformer bank server a balance 3 phase load of 70 kVA at 240 volts and phase…
A: The solution can be achieved as follows.
Q: A 50-kVA 13.8-kV/208-V (rms, line-line) ∆−Ythree-phase distribution transformer has a per-unit…
A: Dear student as per our guidelines we are supposed to solve only one question in which it should…
Q: ratio
A:
Q: Three-phase, 2-winding, 12 MVA, 30/132 kV, star/delta, 50 Hz transformer of equivalent leakage…
A: XL is leakage reactance referred to secondary side. The phasor diagram is
Q: Per-Unit System 3) If a 250MUA,11/400 KU, Three-Phase power Transformer has Zpu of 0.05 pu on the…
A:
Q: The primary and secondary windings of a 500-kVA, 11-kV/415-V, single-phase transformer have…
A:
Q: A 50-kVA 13.8-kV/208-V (rms, line-line) ∆ − Y three-phase distribution transformer has a per unit…
A: Given,High voltage side, line voltage(Base) =13.8 kVApparent power (S)(Base)=50 kVAa) As primary is…
Q: TRUE or FALSE: Purchasing three single-phase transformer bank cost less than one three-phase…
A: In this question we will write in which connection cost is less i.e Purchasing three single-phase…
Q: A 400-MVA, 240-kV/24-KV, three-phase Y-A transformer has an equivalent series impedance of 1.2 + j6…
A: Delta-Star transformer- A Delta-Star transformer is a transformer whose primary side is in delta…
Step by step
Solved in 2 steps with 1 images
- A single-phase 100-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer. The load, which is connected to the 240-volt secondary winding, absorbs 60 kVA at 0.8 power factor lagging and is at 230 volts. Assuming an ideal transformer, calculate the following: (a) primary voltage, (b) load impedance, (c) load impedance referred to the primary, and (d) the real and reactive power supplied to the primary winding.Consider Figure 3.4. For an ideal phase-shifting transformer, the imda nce is unchanged when it is referred from one side to the other. (a) True (b) FalseThree single-phase, two-winding transformers, each rated 450MVA,20kV/288.7kV, with leakage reactance Xeq=0.10perunit, are connected to form a three-phase bank. The high-voltage windings are connected in Y with a solidly grounded neutral. Draw the per-unit equivalent circuit if the low-voltage windings are connected (a) in with American standard phase shift or (b) in Y with an open neutral. Use the transformer ratings as base quantities. Winding resistances and exciting current are neglected.
- Consider a bank of this single-phase two-winding transformers whose high-voltage terminals are connected to a three-phase, 13.8-kV feeder. The low-voltage terminals are connected to a three-phase substation load rated 2.0 MVA and 2.5 kV. Determine the required voltage, current, and MVA ratings of both windings of each transformer, when the high-voltage/low- voltage windings are connected (a) Y-, (b) -Y, (c) Y-Y, and (d) -.A 130-MVA,13.2-kV three-phase generator, which has a positive-sequence reactance of 1.5 per unit on the generator base, is connected to a 135-MVA,13.2/115Y-kV step-up transformer with a series impedance of (0.005+10.1) per unit on its own base. (a) Calculate the per-unit generator reactance on the transformer base. (b) The load at the transformer terminals is 15 MW at unity power factor and at 115 kV Choosing the transformer high-side voltage as the reference phasor, draw a phasor diagram for this condition. (C) For the condition of part (b), find the transformer low-side voltage and the generator internal voltage behind its reactance. Also compute the generator output power and power factor.Consider a single-phase electric system shown in Figure 3.33. Transformers are rated as follows: XY15MVA,13.8/138kV, leakage reactance 10 YZ15MVA,138/69kV, leakage reactance 8 With the base in circuit Y chosen as 15MVA,138kV determine the per-unit impedance of the 500 resistive load in circuit Z, referred to circuits Z, Y, and X. Neglecting magnetizing currents, transformer resistances, and line impedances, draw the impedance diagram in per unit.
- Reconsider Problem 3.64 with the change that now Tb includes both a transformer of the same turns ratio as Ta and a regulating transformer with a 4 phase shift. On the base of Ta, the impedance of the two comp onents of Tb is jO.1 per unit. Determine the complex power in per unit transmitted to the load through each transformer. Comment on how the transformers share the real and reactive pors.The ratings of a three-phase three-winding transformer are Primary(1): Y connected 66kV,15MVA Secondary (2): Y connected, 13.2kV,10MVA Tertiary (3): A connected, 2.3kV,5MVA Neglecting winding resistances and exciting current, the per-unit leakage reactances are X12=0.08 on a 15-MVA,66-kV base X13=0.10 on a 15-MVA,66-kV base X23=0.09 on a 10-MVA,13.2-kV base (a) Determine the per-unit reactances X1,X2,X3 of the equivalent circuit on a 15-MVA,66-kV base at the primary terminals. (b) Purely resistive loads of 7.5 MW at 13.2 kV and 5 MW at 2.3kV are connected to the secondary and tertiary sides of the transformer, respectively. Draw the per- unit impedance diagram, showing the per-unit impedances on a 15-MVA,66-kV base at the primary terminals.A single-phase two-winding transformer rated 90MVA,80/120kV is to be connected as an autotransformer rated 80/200kV. Assume that the transformer is ideal. (a) Draw a schematic diagram of the ideal transformer connected as an autotransformer. showing the voltages, currents, and dot notation for polarity. (b) Determine the permissible kVA rating of the autotransformer if the winding currents and voltages are not to exceed the rated values as a two-winding transformer. How much of the kA rating is transferred by magnetic induction?
- A single-phase 50-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down transformer at the load end of a 2400-volt feeder whose series impedance is (1.0+j2.0) ohm. The equivalent series impedance of the transformer is (1.0+j2.5) ohms referred to the high-voltage (primary) side. The transformer is delivering rated load at a 0.8 power factor lagging and at a rated secondary voltage. Neglecting the transformer exciting current, determine (a) the voltage at the transformer primary terminals, (b) the voltage at the sending end of the feeder, and (c) the real and reactive power delivered to the sending end of the feeder.A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a balanced load of three 1, Y-connected resistors. Choosing a base of 90MVA,66kV for the high-voltage side of the three-phase transformer. spify the base for the low-voltage side. Compute the per-unit resistance of the load on the base for the low-voltage side. Also, determine the load resistance in ohms referred to the high-voltage side and the per-unit value on the chosen base.Three single-phase two-winding transformers, each rated 25MVA,34.5/13.8kV, are connected to form a three-phase bank. Balanced positive-suence voltages are applied to the high-voltage terminals, and a balanced, resistive Y load connected to the low-voltage terminals absorbs 75 MW at 13.8 kV. If one of the single-phase transformers is removed (resulting in an open connection) and the balanced load is simultaneously reduced to 43.3 MW (57.7 of the original value), determine (a) the load voltages Va,Vb, and Vc; (b) load currents Ia,Ib, and Ic; and (c) the MVA supplied by each of the remaining two transformers. Are balanced voltages still applied to the load? Is the open transformer overloaded?