A 2300V, 1000KVA, 0.8PF lagging, 60HZ, two-pole, Y connected synchronous generator has a synchronous reactance of 1.10 and a armature resistance of 0.150. at 60HZ, its friction and windage losses are 20,000W, and its core losses are 18,000w. the field circuit has a DC voltage of 200V and the maximum lr is 10A. the resistance of the field circuit is adjustable over the range from 20 to 20on. The open circuit characteristics is shown in figure below: a) How much field current is required to make Va equal to 2100V when the generator is running at no load? b) What is internal generated voltage of this machine at 80% of rated condition? c) How much field current is required to make Va equal to 2100V when the generator is running at 80% of rated condition? d) How much power and torque must the generator's prime mover be capable of supplying? 20

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter11: Transient Stability
Section: Chapter Questions
Problem 11.3P
icon
Related questions
icon
Concept explainers
Question
Question # 2:
(10)
A 2300V, 1000KVA, 0.8PF lagging, 60HZ, two-pole, Y connected synchronous generator has a
synchronous reactance of 1.10 and a armature resistance of 0.150. at 60HZ, its friction and
windage losses are 20,000w, and its core losses are 18,000w. the field circuit has a DC voltage
of 200V and the maximum Ițis 10A. the resistance of the field circuit is adjustable over the
range from 20 to 20on. The open circuit characteristics is shown in figure below:
a) How much field current is required to make Vi equal to 2100V when the generator is
running at no load?
b) What is internal generated voltage of this machine at 80% of rated condition?
c) How much field current is required to make Va equal to 2100V when the generator is
running at 80% of rated condition?
d) How much power and torque must the generator's prime mover be capable of
supplying?
3000
2700
2400
> 2100
1800
1500
1200
900
600
00
10
20
30
3.0
6.0
10
9.0
100
Fleld cument, A
A vdegos mu ado
Transcribed Image Text:Question # 2: (10) A 2300V, 1000KVA, 0.8PF lagging, 60HZ, two-pole, Y connected synchronous generator has a synchronous reactance of 1.10 and a armature resistance of 0.150. at 60HZ, its friction and windage losses are 20,000w, and its core losses are 18,000w. the field circuit has a DC voltage of 200V and the maximum Ițis 10A. the resistance of the field circuit is adjustable over the range from 20 to 20on. The open circuit characteristics is shown in figure below: a) How much field current is required to make Vi equal to 2100V when the generator is running at no load? b) What is internal generated voltage of this machine at 80% of rated condition? c) How much field current is required to make Va equal to 2100V when the generator is running at 80% of rated condition? d) How much power and torque must the generator's prime mover be capable of supplying? 3000 2700 2400 > 2100 1800 1500 1200 900 600 00 10 20 30 3.0 6.0 10 9.0 100 Fleld cument, A A vdegos mu ado
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Synchronous Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning