Textbook Question
Chapter 4, Problem 4.13P
A single-phase overhead transmission line consists of two solid aluminum conductors having a radius of 3 cm with a spacing 3.5 m between centers. (a) Determine the total line inductance in mH/m. (b) Given the operating frequency to be 60 Hz, find the total inductive reactance of the line in
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A 3-phase transmission line of 100km long has its conductors of 0.5cm diameter spaced at the corners of the equilateral triangle of 120cm side. Find the inductance per phase of the system.
A Three-Phase, 50 Hz, 220 KV
Transmission Line consists of conductors of 1.2 cm radius
spaced 2 meters at the corners of an equilateral triangle.
Calculate the Corona Power Loss per km of the line at a
Temperature of 20ºC and Barometric Pressure of 72.2 cm
of Hg. Take the Surface Factor of the conductor as 0.96
A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2·5 m side. The radius of each conductor is 1 cm. Calculate :
Inductive reactance of aline
line to neutral capacitance of the line
charging current per phase if the line is maintained at 66 kV, 50 Hz.
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- PROBLEM SOLVING NO. 1: A Three-Phase, 75 KV, 50 Hz Transmission Line consists of 0.44 cm radius conductors spaced at 1.2 meters apart in an equilateral triangular formation. If the Temperature is 34°C and Atmospheric Pressure is 75 cm of Hg, calculate the Critical Disruptive Voltage at which Corona occurs. Take m0 = 0.83.arrow_forwardA three phase overhead transmission line has its conductors arranged at the corners of an equilateral triangle of of 2 meters side. calculate the capacitance of each line conductor per kilo meter. given that diameter of each conductor is 1.25 cm. Derive the expression for the capacitance of the transmission linearrow_forwardA. A single-phase transmission line is composed of two solid round conductors having aradius of 0.45cm each. If the conductors are spaced 3.5m, calculatea. the value of the inductance per conductorb. the inductance of the lineB. A 15-km, 60Hz, single phase transmission line consists of two solid conductors, eachhaving a diameter of 0.8cm. If the distance between conductors is 1.25m, determine theinductance and reactance of the line.arrow_forward
- A three phase 60Hz, 120kV transmission line consisting of 3 conductors are placed at the corners of a triangle of sides 20, 15, and 8 meters. The radius of each line conductor is 1.5 cm. The length of the transmission line is 120 km. Assume epsilon subscript 0 equals 8.854 cross times 10 to the power of negative 12 end exponent. Determine d) Capacitance between the line (Cab) Answer for part 4 d) Capacitive reactance between the line( Xab) Answer for part 5 e) Charging Current for the 120 km Answer for part 6arrow_forward8. A single-phase, 10 km transmission line has 16.65 mH total inductance. If the distance betweenthe conductors is 1.0m, what is the conductor diameter? Also, determine the geometric mean radiusof the conductors. Answer: 2.0 cm, 1.558 cmarrow_forward1.A single phase transmission line has two parallel conductors 1·5 metres apart, the diameter of each conductor being 0·5 cm. Calculate line to neutral capacitance for a line 80 km long. 2.A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2·5 m side. The radius of each conductor is 1 cm. Calculate: (i) line to neutral capacitance of the line, (ii) charging current per phase if the line is maintained at 66 kV, 50 Hz. [(i) 2·02 μF (ii) 24·2 A] The three conductors A, B and C of a 3-φ line are arranged in a horizontal plane with DAB = 2 m and DBC = 2·5 m. Find line-to-neutral capacitance per km if diameter of each conductor is 1·24 cm. The conductorsare transposed at regular intervals. [0·0091 μF/km] The three conductors of a 3-φ line are arranged at the corners of a right angled isosceles triangle. If each equal side of this triangle is 2 m, find line-to-neutral capacitance per km. Take the diameter of each conductor as 1·24…arrow_forward
- Estimate the corona loss for a three-phase, 110 kV, 50 Hz, 150 km long transmission line consisting of three conductors each of 10 mm diameter and spaced 2.5 m apart in an equilateral triangle formation. The temperature of air is 40ºC and the atmospheric pressure is 750 mm of mercury. Take irregularity factor as 0.89. Ionization of air may be assumed to take place at a maximum voltage gradient of 30 kV/cm.arrow_forwardA 3-phase, 420 kV transmission line consists of 1·5 cm radius conductor spaced 2 meters apart in equilateral triangular formation. If the dielectric strength of air is 30 kV (max) per cm and corona loss per km of the line is 146.91kW/phase. Take air density factor ∂= 0·952 Estimate: i. irregularity factor ii. comment on type of conductorsarrow_forwardA 110 kV, 50 Hz, 175 km long three-phase transmission line consists of three 1.2 cm diameter stranded copper conductors spaced in a 2 m delta arrangement. Assume that temperature is 25°C and barometric pressure, 74 cm. Assume surface irregularity factor n = 0.85 (roughness factor), mV for local corona = 0.72 and mV for geneal corona = 0.82 Find: (a) disruptive critical voltage, (b) visual corona voltage for loca corona,arrow_forward
- A 200 km, 3-phase transmission line has its conductors placed at the corners of an equilateral triangle of 2·5 m side. The radius of each conductor is 1 cm. Calculate : (i) line to neutral capacitance of the line, (ii) charging current per phase if the line is maintained at 66 kV, 50 Hz.arrow_forwardA bundled 500kv, 60Hz three phase completely transposed overhead line having three ACSR 1113kcmil(556.50mm) conductors per bundle,with 0.5m between conductors in the bundle. The horizontal phase spacings between bundle centers are 10,10,and 20m.Calculate the capacitance -to- neutral in F/m. and the admittance -to-neutral in S/km.arrow_forwardA single-phase transmission line is composed of two solid round conductors having aradius of 0.45cm each. If the conductors are spaced 3.5m, calculatea. the value of the inductance per conductorb. the inductance of the linearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
How do Electric Transmission Lines Work?; Author: Practical Engineering;https://www.youtube.com/watch?v=qjY31x0m3d8;License: Standard Youtube License