A low voltage distribution transformer feeds two different loads with a three-phase line. The nominal voltage of the line is 400 Volt. The total length of the feeder is 500 m. The distance from the transformer to these loads is 140 m and 340 m, respectively. Their consumption is 11 kVA with a 0.8 lagging power factor and 10 kW with a 0.8 lagging power factor, respectively. The feeder's cross-section is 15 mm2 and the feeder's conductivity is 56 m/ohm.mm2. Find the following information. The distance from the transformer to the maximum voltage drop point is The maximum voltage drop is Volt The power loss between the transformer and 11 kVA load is Watt.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.4P: A single-phase 100-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down...
icon
Related questions
Question
A low voltage distribution transformer feeds two different loads with a three-phase line. The nominal voltage of the line is 400 Volt. The total length of the feeder is
500 m. The distance from the transformer to these loads is 140 m and 340 m, respectively. Their consumption is 11 kVA with a 0.8 lagging power factor and 10 kW
with a 0.8 lagging power factor, respectively. The feeder's cross-section is 15 mm2 and the feeder's conductivity is 56 m/ohm.mm2. Find the following information.
The distance from the transformer to the maximum voltage drop point is
m
The maximum voltage drop is
Volt
The power loss between the transformer and 11 kVA load is
Watt.
Transcribed Image Text:A low voltage distribution transformer feeds two different loads with a three-phase line. The nominal voltage of the line is 400 Volt. The total length of the feeder is 500 m. The distance from the transformer to these loads is 140 m and 340 m, respectively. Their consumption is 11 kVA with a 0.8 lagging power factor and 10 kW with a 0.8 lagging power factor, respectively. The feeder's cross-section is 15 mm2 and the feeder's conductivity is 56 m/ohm.mm2. Find the following information. The distance from the transformer to the maximum voltage drop point is m The maximum voltage drop is Volt The power loss between the transformer and 11 kVA load is Watt.
Expert Solution
steps

Step by step

Solved in 5 steps

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning