A) The circuit of the thermocouple made of iron and Constantan is shown in Figure 4. If the base connection is inside the ice container 0 °C and the output voltage of the thermocouple is 2.1mV, obtain the connection point temperature. B) If in the thermocouple circuit discussed in section A (shown in Figure 5), ice is melted in the container in which the base connection is located, so that it turns into water with a temperature of 25°C and the connection related to the temperature measurement in Remained the same temperature, what is the output voltage of the thermocouple? Iron Constantan Iron Potentiometer Measuring junction

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

S4) just Solve A

A) The circuit of the thermocouple made of iron and Constantan is shown in Figure 4.
If the base connection is inside the ice container 0 °C and the output voltage of the thermocouple is
2.1mV, obtain the connection point temperature.
B) If in the thermocouple circuit discussed in section A (shown in Figure 5), ice is melted in the
container in which the base connection is located, so that it turns into water with a temperature of
25°C and the connection related to the temperature measurement in Remained the same
temperature, what is the output voltage of the thermocouple?
Iron
Potentiometer
Constantan
Iron
Measuring
junction
Ice bath
Reference
junction
Figure 4 Circuits for a thermocouple made of iron and Constantan.
C) If copper branches are added to the thermocouple circuit according to the figure below. In the case
where the connection of the base inside the ice 0°C
And the output voltage is 2.1 mv, calculate the temperature of the measuring connection.
Iron
Copper
Constantan
Copper
Potentiometer
Measuring
junction
Ice bath
-Reference
junction
Figure 5: Thermocouple circuit made of iron, Constantan and copper.
The thermoelectric sensitivities for constantane, copper and iron in contact with platinum
at 0°C are-35", +6" and +18.5 respectively.
Transcribed Image Text:A) The circuit of the thermocouple made of iron and Constantan is shown in Figure 4. If the base connection is inside the ice container 0 °C and the output voltage of the thermocouple is 2.1mV, obtain the connection point temperature. B) If in the thermocouple circuit discussed in section A (shown in Figure 5), ice is melted in the container in which the base connection is located, so that it turns into water with a temperature of 25°C and the connection related to the temperature measurement in Remained the same temperature, what is the output voltage of the thermocouple? Iron Potentiometer Constantan Iron Measuring junction Ice bath Reference junction Figure 4 Circuits for a thermocouple made of iron and Constantan. C) If copper branches are added to the thermocouple circuit according to the figure below. In the case where the connection of the base inside the ice 0°C And the output voltage is 2.1 mv, calculate the temperature of the measuring connection. Iron Copper Constantan Copper Potentiometer Measuring junction Ice bath -Reference junction Figure 5: Thermocouple circuit made of iron, Constantan and copper. The thermoelectric sensitivities for constantane, copper and iron in contact with platinum at 0°C are-35", +6" and +18.5 respectively.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Routh Hurwitz Criteria
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,