An 11-kV, 1000-kVA, 3-phase, Y-connecied alternator has a resistance of 22 per phase. The open-circuit and full-load zero power factor characteristics are given below. Find the voltage regulation of the alternator for full load current at 0.8 p.f. lagging by Potier method
Q: Two three-phase, 6.6 kV, Y-connected synchronous generators are operating in parallel to supply a…
A: A) Given:Vt=6.63kV=3810 VZA=j10ΩZB=j12ΩTotal load of 3000 kW at 0.8 p.f. laggingPT=3000 kWQT=3000…
Q: A 3-phase, Y-connected synchronous generatorisrated 15 MVA, 13.8 kV. Its resistance is negligible,…
A: An alternator/Synchronous generator is a type of electrical machine that converts mechanical energy…
Q: 1) A 4.16 kV, three-phase induction machine based wind generator supplies a load of 294 KW at a…
A:
Q: A 6,600V, 1,200 kVA, 3-phase alternator is delivering full load at 0.80 power factor lagging. Its…
A: The solution is given below
Q: Which of the following is more likely to cause problems with motors? a) positive sequence harmonics,…
A: Which of the following is more likely to cause problems with motors? Negative sequence harmonics,…
Q: An 11-kV, 1000-kVA, 3-phase, Y-connected alternator has a resistance of 2 per phase. The…
A:
Q: A3-phase, F--connected, 2-pole alternator nuns at 3,600 rp.m. If there are 500 conductors per phase…
A: 3ϕ,Y = 2 pole . #600 rpm , 500 conductors/phase ϕ = 0.1 , f= ? , Emf/phase = ? Ns = 120fPf= NsxP120…
Q: In three phase, a 100KVA, 6.6 kV Y-connected cylindrical pole synchronous gen. has 20-ohm as…
A: The circuit diagram for the synchronous generator is shown below: Where, Ef is the induced emf and…
Q: : A three phase alternator is rated at 120 mva,13.2 kv,0.8 pf lagging, and 60 Hz. direct axis…
A: In the given question we note that A three-phase alternator is rated at 120 MVA , 13.2 Kv Power…
Q: Power coefficient of a 3-phase, star-connected, salient-pole synchronous generator, ignoring the…
A: Power coefficient of a 3-phase, star-connected, salient-pole synchronous generator, ignoring the…
Q: Or (a) For a compound de generator, there are three windings which are shunt field winding, series…
A: According to question: The circuit of compound dc generator will be as given below:
Q: A step-down chopper, with voltage source 20V. If the duty cycle is 50% and chop frequency is 0.1Hz,…
A: In this question , step down chopper is given...We have to find out ON time of chopper and average…
Q: A three-phase Y-connected alternator delivers a unity power-factor load at 220 volts. If the…
A: In this question, we need to calculate a. calculate the generated voltage b. calculate the percent…
Q: In a single-phase alternator, a given field current produces an armature current of 250 A on…
A:
Q: Example: A30,5KVA,208V,60HZ,synchronous machine has negligible stator winding resistance and Xs =80…
A: Given information a three phase synchronous machine which is operated as a generator is, Rated…
Q: A 250 MVA, 25 kV, 3 phase synchronous generator has a synchronous reactance X, of 1.6 pu. It is…
A: According to company policy, i am solve only first 3 part. We can draw the given power system as a)…
Q: Figure Q2(a): Synchronous Generator (i) Name the type of synchronous generator as shown in Figure…
A: A synchronus generator is a synchronus machine which converts mechanical power into AC electric…
Q: The leakage reactance(XL) and the armature reactance (Xm) of the three phase unloaded alternator…
A: False
Q: A 6600V, 3-ph, Y-connected alternator has a synchronous impedance of (0.4+j6) ohm per phase.…
A:
Q: Q5) A Three- phase alternator ( Synchronous Generator) SG , 12 KV , 1.5 MVA, star connected armature…
A: Voltage regulation =( (Ef-Vt)/Vt)*100 Where Ef = per phase armature induced voltage and Vt =per…
Q: A 3-phase Y-connected alternator delivers a unity power-factor load at 200 volts. If the…
A: Given: 3 phase alternators Unity Power factor Load Vf = 200 Volt…
Q: For two parallel synchronous generators of the same size and same droop in frequency-Active Power…
A: for two parallel synchronous generators of the same size and same droop in frequency active power…
Q: A three-phase star-connected alternator is rated at 1750 KVA, 13.8 KV, The armature resistance and…
A:
Q: Explain the conditions of parallel connection of alternators and how these conditions are fulfilled.
A: If the value of the power demand is large then, it is not possible to provide the power by using a…
Q: 1 MVA, 11kV,three-phase wye-connected synchronous generator has a synchronous reactance of 5 ohms…
A:
Q: A Three phase Y connected alternator delivers a unity power factor load at 230 volts. If the…
A:
Q: Explain the Brush less excitation scheme of Synchronous generator with Pilote excitor. Also identify…
A: You have asked multiple independent questions. We are authorized to answer one question at a time.…
Q: A three-phase synchronous generator is being used as a source of power for a farm in a remote area…
A: It is given that the configuration of the alternator is a star. The per-phase open-circuit voltage…
Q: single-phase alternator resistance of 0.20 ohm. A field resistance of 10A produces an armature…
A:
Q: A shunt generator supplies a 25kW load at 235V through cables of resistance, R = 116mn. If the field…
A:
Q: Q) A P-Pole three-phase induction machine with spatial distribution of stator windings is assumed to…
A: We will find that the , two cycles of emf is produced in one complete revolution of conductor.…
Q: Derive current, active and reactive power equations of a three-phase synchronous generator along…
A: E1=E2+IZwhere Z is R+jXTherefore the current,I=E1Z-E2Z components of current in phase with the…
Q: A three phase 6000 V Alternator gave the following open circuit characteristic at normal speed:…
A: Given : Three phase 6000 v alternator Field current in ampr 14 ,18,23,30,43Terminal voltage in volt…
Q: If, in a 3-4 alternator, a field current of 50 A produces a full-load armature current of 200 A on…
A: Given, A 3-φ alternator has, Field current of 50 A Open circuit line voltage, Vocline=1730 V Open…
Q: An 11-kV, 1000-kVA, 3-phase, Y-connected alternator has a resistance of 2 0 per phase. The…
A:
Q: Referring to the rated values of the components in Figure Q.2, draw the impedance diagram with all…
A:
Q: A 1MVA, 11 KV, three phase wye-connected synchronous generator has a synchronous reactance of 5 ohms…
A:
Q: An AC alternator is used to convert mechanical power to electrical power. Energy in mechanical form…
A: Please mention the voltage in part C as that data is missing. Part(a):- An AC alternator is a device…
Q: A 1 MVA, 11 KV, three phase wye-connected synchronous generator has a synchronous reactance of 5…
A: It is given that: Xs=5ΩVt=11kVS=1MVA
Q: A 1200 kVA, 6600 volts, three-phase wye connected alternator, has an effective resistance of 2.5…
A: The solution is given below
Q: TWO SINGLE -PHASE ALTERNATORS HAS AN ARMATURE WINDING 'HOSE RESISTANCE AND SYNCHRONOUS REACTANCE…
A:
Q: Two 50-MVA, 3-phase alternators operate in parallel. The settings of the governors are such that the…
A:
Q: Calculate the synchronizing torque for unit mechanical angle of phase displacement for a 5,000-kVA,…
A: Given data, S = 5000 kVA f = 50 Hz N = 1500 rpm V = 6600 V Xs = 0.15 pu Poles = 4
Q: UDng a ITIe Core in high frequency transformers. c- Discuss, different applications of iron cores of…
A: C)For magnetizing or demagnetizing a iron material, some energy is expended. The energy expended…
Q: Two alternators rated 400 MW and 600 MW are operating in parallel. The droop characteristics of…
A: The solution is given below
Q: A power plant comprises three turbine-generators rated 1000 MW, 800 MW and 600 MW respectively. The…
A: Note: We are authorized to answer three subparts at a time since you have not mentioned which part…
Q: A1 MVA, 11 KV, 3-phase wye- connected synchronous generator has a synchronous reactance of 5 ohms…
A: The solution is given below
Q: Show that an alternator running in parallel on constant-voltage and frequency bus-bars has a natural…
A:
Step by step
Solved in 2 steps with 1 images
- Consider a three-phase generator rated 300MVA,23kV, supplying a system load of 240 MA and 0.9 power factor lagging at 230 kV through a 330MVA,23/230Y-kV step-up transformer with a leakage reactance of 0.11 per unit. (a) Neglecting the exciting current and choosing base values at the load of 100 MVL and 230 kV. Find the phasor currents IA,IB, and IC supplied to the load in per unit. (b) By choosing the load terminal voltage IA as reference, specify the proper base for the generator circuit and determine the generator voltage V as well as the phasor currents IA,IB, and IC, from the generator. (Note: Take into account the phase shift of the transformer.) (C) Find the generator terminal voltage in kV and the real power supplied by the generator in MW. (d) By omitting the transformer phase shift altogether, check to see whether you get the same magnitude of generator terminal voltage and real power delivered by the generator.While the instantaneous electric power delivered by a single-phase generator under balanced steady-state conditions is a function of time havi ng two components of a constant and a double-frequency sinusoid, the total instantaneous electric power delivered by a three-phase generator under balanced steady-state conditions is a constant. (a) True (b) FalseA 130-MVA,13.2-kV three-phase generator, which has a positive-sequence reactance of 1.5 per unit on the generator base, is connected to a 135-MVA,13.2/115Y-kV step-up transformer with a series impedance of (0.005+10.1) per unit on its own base. (a) Calculate the per-unit generator reactance on the transformer base. (b) The load at the transformer terminals is 15 MW at unity power factor and at 115 kV Choosing the transformer high-side voltage as the reference phasor, draw a phasor diagram for this condition. (C) For the condition of part (b), find the transformer low-side voltage and the generator internal voltage behind its reactance. Also compute the generator output power and power factor.
- Consider a single-phase electric system shown in Figure 3.33. Transformers are rated as follows: XY15MVA,13.8/138kV, leakage reactance 10 YZ15MVA,138/69kV, leakage reactance 8 With the base in circuit Y chosen as 15MVA,138kV determine the per-unit impedance of the 500 resistive load in circuit Z, referred to circuits Z, Y, and X. Neglecting magnetizing currents, transformer resistances, and line impedances, draw the impedance diagram in per unit.Three single-phase two-winding transformers, each rated 3kVA,220/110volts,60Hz, with a 0.10 per-unit leakage reactance, are connected as a three-phase extended autotransformer bank, as shown in Figure 3.36(c). The low-voltage winding has a 110 volt rating. (a) Draw the positive-sequence phasor diagram and show that the high-voltage winding has a 479.5 volt rating. (b) A three-phase load connected to the low-voltage terminals absorbs 6 kW at 110 volts and at 0.8 power factor lagging. Draw the per-unit impedance diagram and calculate the voltage and current at the high-voltage terminals. Assume positive-sequence operation.With the same transformer banks as in Problem 3.47, Figure 3.41 shows the oneline diagram of a generator, a step-up transformer bank, a transmission line, a stepown transformer bank, and an impedan load. The generator terminal voltage is 15 kV (line-to-line). (a) Draw the per-phase equivalent circuit, aounting for phase shifts for positive-sequence operation. (b) By choosing the line-to-neutral generator terminal voltage as the reference, determine the magnitudes of the generator current, transmiss ion-line current, load current, and line-to-line load voltage. Also, find the three-phase complex power delivered to the load.
- Three single-phase, two-winding transformers, each rated 450MVA,20kV/288.7kV, with leakage reactance Xeq=0.10perunit, are connected to form a three-phase bank. The high-voltage windings are connected in Y with a solidly grounded neutral. Draw the per-unit equivalent circuit if the low-voltage windings are connected (a) in with American standard phase shift or (b) in Y with an open neutral. Use the transformer ratings as base quantities. Winding resistances and exciting current are neglected.Consider the oneline diagram shown in Figure 3.40. The three-phase transformer bank is made up of three identical single-phase transformers, each specified by X1=0.24 (on the low-voltage side), negligible resistance and magnetizing current, and turns ratio =N2/N1=10. The transformer bank is delivering 100 MW at 0.8 p.f. lagging to a substation bus whose voltage is 230 kV. (a) Determine the primary current magnitude, primary voltage (line-to-line) magnitude, and the three-phase complex power supplied by the generator. Choose the line-to-neutral voltage at the bus, Va as the reference Account for the phase shift, and assume positive-sequence operation. (b) Find the phase shift between the primary and secondary voltages.Consider the single-line diagram of the power system shown in Figure 3.38. Equipment ratings are Generator 1: 1000MVA,18kV,X=0.2perunit Generator 2: 1000MVA,18kV,X=0.2p.u. Synchronous motor 3: 1500MVA,20kV,X=0.2p.u. Three-phase -Y transformers T1,T2,T3,T4,: 1000MVA,500kV,Y/20kV,X=0.1p.u. Three-phase YY transformer T5: 1500MVA,500kV,Y/20kVY,X=0.1p.u. Neglecting resistance, transformer phase shift, and magnetizing reactance, draw the equivalent reactance diagram. Use a base of 100 MA and 500 kV for the 50-ohm line. Determine the per-unit reactances.
- Three single-phase two-winding transformers, each rated 25MVA,34.5/13.8kV, are connected to form a three-phase bank. Balanced positive-suence voltages are applied to the high-voltage terminals, and a balanced, resistive Y load connected to the low-voltage terminals absorbs 75 MW at 13.8 kV. If one of the single-phase transformers is removed (resulting in an open connection) and the balanced load is simultaneously reduced to 43.3 MW (57.7 of the original value), determine (a) the load voltages Va,Vb, and Vc; (b) load currents Ia,Ib, and Ic; and (c) the MVA supplied by each of the remaining two transformers. Are balanced voltages still applied to the load? Is the open transformer overloaded?Sketch the complete per-phase equivalent circuit of a symmetrical non-salient pole three-phase synchronous generator, including the field winding circuit. Your figure should include the synchronous reactance Xs, explain its relation to Xar and Xl. In addition, explain/describe the rest of the different elements of this equivalent circuit.Three-phase alternator supplying a three wires, CBA system with a line voltage of 100 Volt, connected to a three impedances of 3 - j 4 in Delta connection. Determine the line current, phase current, phase and line voltage and draw the voltage-current phasor diagram, assuming that VBC is the reference vector.