Determine if the following are systematic or random errors. It if is systematic classify it as personal, method or instrumental error. a. A 25-mL transfer pipet consistently delivers 25.031 ± 0.009 mL. b. A 10-mL buret delivered 1.9839 g of water when drained from exactly 0.00 to 2.00 mL. The next time I delivered water from the 0.00 to the 2.00 mL mark, the delivered mass was 1.9900 g. c. A 10-mL buret consistently delivers 1.98 ± 0.01 mL when drained from exactly 0 to exactly 2 mL and consistently delivers 2.03 mL ± 0.02 mL when drained from 2 to 4 mL. d. Four consecutive 20.0- L injections of a solution into a chromatograph were made and the area of a particular peak was 4 383, 4 410, 4 401, and 4 390 units. e. A hygroscopic unknown being weighed was not dried prior to the experiment. f. One component of a mixture being determined quantitatively by chromatography reacts with the column packing. g. A radioactive sample being counted repeatedly without any change in conditions yields a slightly different count at each trial. h. The tip of the pipet used in the analysis is broken

Chemistry & Chemical Reactivity
9th Edition
ISBN:9781133949640
Author:John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
ChapterL: Let's Review
SectionL.2: Making Measurements: Precision, Accuracy, Experimental Error, And Standard Deviation
Problem 1RC
icon
Related questions
Question
100%

Determine if the following are systematic or random errors. It if is systematic classify it as personal, method or instrumental error.

a. A 25-mL transfer pipet consistently delivers 25.031 ± 0.009 mL.
b. A 10-mL buret delivered 1.9839 g of water when drained from exactly 0.00 to 2.00
mL. The next time I delivered water from the 0.00 to the 2.00 mL mark, the
delivered mass was 1.9900 g.
c. A 10-mL buret consistently delivers 1.98 ± 0.01 mL when drained from exactly 0
to exactly 2 mL and consistently delivers 2.03 mL ± 0.02 mL when drained from 2
to 4 mL.
d. Four consecutive 20.0- L injections of a solution into a chromatograph were made
and the area of a particular peak was 4 383, 4 410, 4 401, and 4 390 units.
e. A hygroscopic unknown being weighed was not dried prior to the experiment.
f. One component of a mixture being determined quantitatively by chromatography
reacts with the column packing.
g. A radioactive sample being counted repeatedly without any change in conditions
yields a slightly different count at each trial.
h. The tip of the pipet used in the analysis is broken

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Statistics and Analytical Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry & Chemical Reactivity
Chemistry & Chemical Reactivity
Chemistry
ISBN:
9781133949640
Author:
John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:
Cengage Learning
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning