Induction motor the following data of a squirrel cage induction motor in delta connection are given nominal conditions Stator voltage V1 N(delta)=40ov stator freq f1 N=50HZ stator current 11 N=40A pole pair number p=10 open circuit conditions stator voltage V1 N(delta)=400v active power P1 oc=0W reactive power Q1 oc=9.3KVA short circuit conditions stator voltage V1 N(delta)=400V active power P1 sc=13.9kW reactive power Q1 sc=110.9 kVA for all calculations ,all losses are neglected,except the ohmic losses of the roto Calculate open circuit current ,short circuit current determine nominal slip SN,pull out slip Spo and power factor cos(phi)N and draw complete current locus and scale the slip line 1cm=10A

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.21P: An industrial plant consisting primarily of induction motor loads absorbs 500 kW at 0.6 power factor...
icon
Related questions
Question

solve the problems

Induction motor
the following data of a squirrel cage induction motor in delta connection are given
nominal conditions
Stator voltage V1 N(delta)=40ov
stator freq f1 N=50HZ
stator current 11 N=40A
pole pair number p=10
open circuit conditions
stator voltage V1 N(delta)=400v
active power P1 oc=0W
reactive power Q1 oc=9.3KVA
short circuit conditions
stator voltage V1 N(delta)=400V
active power P1 sc=13.9kW
reactive power Q1 sc=110.9 kVA
for all calculations ,all losses are neglected,except the ohmic losses of the roto
Calculate open circuit current ,short circuit current
determine nominal slip SN,pull out slip Spo and power factor cos(phi)N
and draw complete current locus and scale the slip line 1cm=10A
Transcribed Image Text:Induction motor the following data of a squirrel cage induction motor in delta connection are given nominal conditions Stator voltage V1 N(delta)=40ov stator freq f1 N=50HZ stator current 11 N=40A pole pair number p=10 open circuit conditions stator voltage V1 N(delta)=400v active power P1 oc=0W reactive power Q1 oc=9.3KVA short circuit conditions stator voltage V1 N(delta)=400V active power P1 sc=13.9kW reactive power Q1 sc=110.9 kVA for all calculations ,all losses are neglected,except the ohmic losses of the roto Calculate open circuit current ,short circuit current determine nominal slip SN,pull out slip Spo and power factor cos(phi)N and draw complete current locus and scale the slip line 1cm=10A
Expert Solution
steps

Step by step

Solved in 9 steps with 8 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning