Q1.(b) A D.C. Shunt generator runs at 400 rpm and delivers 500 KW to bus-bars having a constant voltage of 400V. Assuming the field excitation to be constant at 5A, Calculate the speed at which the generator must run if the load on it is to be reduced to 300KW. The armature resistance is 0.015Q?
Q: A separately excited generator,when running at 1000rpm supplied 200A at 125V. What will be the load…
A:
Q: LA 25 KW, 250V, dc shunt generator has armature and field resistance of 0.060 and 100 Q…
A:
Q: The figure shows the excitation curve (including residual voltage) of a 170 kW, 250 V DC shunt…
A: Given curve is for 850 rpm rated current. Nrated =850
Q: Q1. The following data refer to the O.c.C of a D.C separately excited generator at 1000 rpm. Field…
A: As per our guide lines I solved only one question.
Q: Q1. The following data refer to the O.C.C of a D.C separately excited generator at 1000 rpm. Field…
A: D.C separately excited generator; OCC characteristic, speed N=1000 r.p.m Rsh=200Ω
Q: The armature resistance of a 50 KW, 240 V foreign excited generator is 0.02 ohms. Generator Rated…
A:
Q: Ql:A: The following data apply to a 100-kW 250-V six-pole, 900-rpm compound generator (long-shunt…
A: The different types of losses in a dc generator are, 1. Copper losses 2. Iron losses 3. Mechanical/…
Q: 2: Find the efficiency of DC compound motor (long shunt); armature current (101.3 A), rotate at…
A:
Q: Q3) Calculate la, the induced e.m.f., and the output of prime mover for a short - shunt compound…
A: Given, The load current is 50 A The load voltage is 380 V
Q: Q1/ A 230 V, 250 hp (1 hp = 745.7 W), and 435 r/min dc shunt motor has nominal full load current of…
A: Given data: V =232 V Full load current I=862 A Pout=250 hP =37285 W
Q: Q.2: A long-shunt compound DC generator, has armature, series field and shunt field resistances of…
A: In this question, Long shunt dc generator is given. Find the efficiency of motor at different…
Q: A separately excited DC generator has rated terminal voltage and full load armature current of 200 V…
A: Terminal Voltage Vt = 200 V Line current IL = 50 A Speed N = 1500 rpm Armature resistance Ra = 0.4…
Q: Q23) A shunt generator supplies a 20KW load at 200V through cables of resistance, R = 100mΩ. If the…
A:
Q: Example 8.19. A separately excited d.c. generator, when running at 1200 r.p.m. supplies 200 A at 125…
A: In this question we will find current when speed dropped for separately excited dc generator....
Q: (a) A 25 kW, 250 V, DC shunt generator has armature resistance of 0.06 Q and field resistance of 100…
A:
Q: 5. A separately-excited DC generator produces an open-circuit voltage of 240V with field current of…
A:
Q: A 480 V, 200 kVA, 0.8 power factor leading, 60 Hz, two-pole, A connected synchronous generator has a…
A:
Q: 2. A 110 V shunt generator has a full-load current of 100 A, shunt field resistance of 55 ohms and…
A: GivenTerminal voltage= 110 vFull load current IFL=100 AShunt field resistance Rsh=55 Ωconstant…
Q: Example (1.4) :U A 4-pole, long-shunt lap-wound compound generator delivers a load current of (50 A)…
A: A DC machine is classified in two types. DC motors DC generators Above question is based on DC…
Q: 2. A d.c. shunt generator gave the following open-circuit characteristic when driven at 750 r.p.m.…
A: As per our policy we can provide solution of first three questions only As we have given: The OCC of…
Q: Q1. The following data refer to the O.C.C of a D.C separately excited generator at 1000 rpm. Field…
A: Occ graph with given data, from this graph find the no load generated emf.
Q: A 250V shunt generator has a rated armature current of 40A and the following losses at full load:…
A: Given 250 V shunt generator rated armature current of 40A friction and windage = 200 watts core…
Q: A DC shunt generator has avoltage on open circuit of 150V. When machine is on load, the terminal…
A: DC machines (Generator/ Motor) are the important parts of electrical drives. These machines are used…
Q: Q3)A DC shunt generator has avoltage on open circuit of 150V. When machine is on load, the terminal…
A: DC machines (Generator/ Motor) are the important parts of electrical drives. These machines are used…
Q: Q3 (A) A separately excited de generator produces a no-load voltage of 115 V. find generated voltage…
A:
Q: ase the speed slightly or decre shunt-field-circuit resistance slightly. Example 8.21(a). A 6-pole…
A: In this question we will find flux per pole , pole arc length and average air gap flux density....
Q: Q: A four pole sclf excited DC shunt generator ruining at 104,66 rad's, supplics resistive load 18…
A:
Q: A Four pole, 50kW, 250 Volt Long Shunt DC Machine Generator has a shunt field current of 1.5 A. It…
A: In this question we need to find a armature current , generated emf and flux per pole.
Q: Assuming constant field excitation, calculate the no-load…
A: Given separately excited generator with constant field excitation Armature voltage is 150 v at speed…
Q: A 240 volts dc shunt generator has a full-load armature current of 50 Amperes, under with condition…
A:
Q: To ensure a successful voltage buildup, the self-excited dc generator must be started with a shunt…
A: The correct answer is option b, Lesser than the maximum slope of its magnetization curve. Critical…
Q: The armature, series field and shunt field resistances of a 125kW, 250V long shunt cumulative…
A:
Q: Example 5: A short-shunt compound generator delivers a load current of 30 A at 220 V, and has…
A: The solution can be achieved as follows.
Q: Q1. shunt generator delivers a full-Hoad outpu power of 8 Kw at 200 V. It has an armature and shunt…
A: According to our policy , we will answer only the first part of the question . If you want solution…
Q: Q1. shunt generator delivers a full-Hoad outpu power of 8 Kw at 200 v. It has an armature and shunt…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: Q1: A: A 10 kW, 230 V, 1750 rpm shunt generator was run light as a motor to determine its rotational…
A: Circuit diagram for running light load test, To determine rotation loss, light load test is…
Q: 20 KW DC generator having Armature resistance of 0.2 ohms, field resistance of 100 ohms supplies…
A: We need to find out terminal voltage and generated emf and efficiency of given machine .
Q: Q6) A separately excited DC generator, when running at 1000 rpm supplied 200A at 125V. What will be…
A: In the question, What is the armature current if the speed drop 800rpm. Assume field current are…
Q: A shunt generator supplies a 20kW load at 200V through cables of resistance, R= 100mΩ. If the field…
A: Dc shunt Generator
Q: 15. A 1500 kW, 550-V, 16 pole generator runs at 150 rev. per min. What must be the useful flux if…
A:
Q: A 100kW, 230V, shunt generator has an armature resistance and field resistance of 0.05Ω and 57.5Ω.…
A:
Q: Q The field and armature resistance of a four-pole shunt generator with Lap -connected armature is…
A: Given Data: Number of pole = P = Number of parallel path A = 4 P = 2400 W V = 100 V Rsh = 50 ohm Ra…
Q: A 20KW, 440V, short shunt compound dc generator has full load efficiency of 87%. If the resistance…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: A 10 kW, 250 V, dc shunt motor with an armature resistance of 0.8 Ω and a field resistance of 275 Ω…
A: DC shunt motor is known as a wound DC motor it is a self excited DC motor the field winding is…
Q: a) A separately excited DC generator when running at 1200 rpm supplies 200 A at 125 V to a círcuit…
A:
Q: Of a shunt excited DC generator, Excitation winding internal resistance Rf = 2.5 Ω Armature winding…
A:
Q: A 250 V shunt generator has a full load armature current of 40 A. Under this condition the losses…
A: Given: A 250 V shunt generator has a full load armature current of 40 A. Under this condition the…
Q: shunt generator with a capacity of 250 kW and a voltage of 250 V has an armature circuit resistance…
A: Given, A shunt generator has, Terminal voltage (Vt)= 250 V Output power (Pout) = 250 kW Armerture…
Q: Tutorial: DC Generator Characteristics Q1. The following data refer to the O.C.C of a D.C separately…
A: DC shunt generator 1000 rpm total field resistance 200Ω armature resistance 0.8 ohm terminal voltage…
Q: A separately excited DC generator has rated terminal voltage and full load armature current of 200 V…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Step by step
Solved in 3 steps with 2 images
- Q/ dc shunt generator 4 pole with 500 condcutor , wave running at speed 1000 r.p.m the resistance of armature and field are 0.02 , 55 ohm and delivering load 43.12kwatt at terminal voltage 220 volt, the iron losses is 750 watt 1-Torque developed by the prime mover .........and The torque developed by the armature ........... when running at 1000 r.p.m * 2-The load current ,,,,,,,,,,,,when the speed drops to 800 r.p.m. if If is unchanged ? * 3-Output of the prime motor…….kwatt * 4-Mechanical , electrical and overall efficiency …….. * 5-Flux per pole is......... wb *A 110V shunt generator has a full load current of 100A, shunt field resistance of 55 ohms and constant losses of 500W. If full load efficiency is 88%, find the armature resistance. Assuming voltage to be constant at 110V, calculate the efficiency at half load. Find the load current.A 20KW, 440V, short shunt compound dc generator has full load efficiency of 87%. If the resistance of the armature and interpoles is 0.4ohm and that of the series and shunt fields 0.25ohm and 240ohms respectively, calculate the combined bearing friction, windage and core loss of the machine A 10 kW 250 volts self-excited generator, when delivering rated load, has an armature-circuit voltage drop of 5% of the terminal voltage and a shunt field current equal to 5% of the rated load current. The resistance of the armature is 0.02 ohm. Calculate the voltage generated and power output.
- D.C. Shunt generator runs at 400 rpm and delivers 500 KW to bus-bars having a constant voltage of 400V. Assuming the field excitation to be constant at 5A, Calculate the speed at which the generator must run if the load on it is to be reduced to 300KW. The armature resistance is 0.0150?Electrical Engineering Problem. Please help to provide correct solution for the problem. Please show neat solution Thanks. A 100kW, 230V, shunt generator has an armature resistance and field resistance of 0.05Ωand 57.5Ω. If the generator operates at rated voltage. SPL is 1.8kW,a) At what load does the generator achieve maximum efficiency?b) What is the value of this maximum efficiency?A 10 kW shunt generator having an armature circuit resistance of 0.75 ohm and a field resistance of 125 ohm, generates a terminal voltage of 250V at full load. Determine the efficiency of the generator at full load, assuming the iron, friction and windage losses amount to 600W.
- A separately excited generator,when running at 1000rpm supplied 200A at 125V. What will be the load current when the speed drops to 800rpm if current is unchanged? Given the armature resistance of 0.04 ohms and brush drop of 2V.the armature series field and shunt field resistance of a 125 kw, 250V long shunt cumulative compound DC generator are 0.025ohms, 0.01ohms and 30 ohms, respectively. If the stray power stray loss at rated load is 25 kW, determine the power in the shunt field. Assume a astray load loss of 1% of the load power output (note: Input power generator is equal to the motor brake horsepower, Pin=Pl+Plosses) Choices A. 2034.5 W B.2082.5 W C. 2065.5 W D. 2053.5 WA 200V dc shunt generator can deliver 10 kW at half load with efficiency of83 %. If the armature resistance is 0.05 ohms and shunt field resistance of 50ohms. What will be the efficiency of the generator when running at full load?
- Q8/ A 20 KW DC generator having Armature resistance of 0.2 ohms, field resistance of 100 ohms supplies 100 A load current at full load. (a) What is the terminal voltage of the generator at full load? (b) What is the generated EMF of the Generator? (c) What is the efficiency of the generator at full load, assuming the Iron, Friction and Windage losses around 1 kW.A Four pole, 50kW, 250 Volt Long Shunt DC Machine Generator has a shunt field current of 1.5 A. It is Lap-winded with 872 conductors, and a rated speed of 1200 RPM. Where, Ra = 100 mohms, and Rse = 0.05 ohms. Solve for the following: Armature Current Generate EMF Total Flux per pole21 A 25 kW, 240 V self excited dc shunt generator has a field circuit resistance of 62.5 Ω, and an armature resistance of 0.05 Ω. When delivering rated current at rated speed and voltage, calculate % Efficiency when rotational losses are 1200W, and iron losses are 600W. Note that Copper losses must be calculated too. No Units! Please answer in typing format please ASAP for