room in a building has dimensions of 5.5 mx 4,5 m x 3.0 m. The room has two external walls and two external vindows of single clear glass. The area of each window is 2 m?. The overalI heat transfer coefficients for the walls, lass windows, and the ceiling are 2.0, 5.2, and 1.2 W/m K, respectively. The inside and outside design temperatures re 23 °C and -5 °C, respectively. Calculate the followings: a- The unheated mean radiant temperature. b- Explore the possibility of using underfloor heating system to heat the room. C- Minimum floor area needed for the underfloor heating system. d- Water flow rate. e- pump head required for underfloor heating system. Make reasonable assumption concerning the number of pipe loops and pipe diameter.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter8: Natural Convection
Section: Chapter Questions
Problem 8.8P
icon
Related questions
Question
i need the answer quickly
room in a building has dimensions of 5,5 m x 4,5 m x 3.0 m. The room has two external walls and two external
vindows of single clear glass. The area of each window is 2 m. The overal1 heat transfer coefficients for the walls.
lass windows, and the ceiling are 2.0, 5.2, and 1.2 W/m K, respectively. The inside and outside design temperatures
re 23 °C and -5 °C, respectively. Calculate the followings:
a- The unheated mean radiant temperature.
b- Explore the possibility of using underfloor heating system to heat the room.
C- Minimum floor area needed for the underfloor heating system.
d- Water flow rate.
e- pump head required for underfloor heating system.
Make reasonable assumption concerning the number of pipe loops and pipe diameter.
Transcribed Image Text:room in a building has dimensions of 5,5 m x 4,5 m x 3.0 m. The room has two external walls and two external vindows of single clear glass. The area of each window is 2 m. The overal1 heat transfer coefficients for the walls. lass windows, and the ceiling are 2.0, 5.2, and 1.2 W/m K, respectively. The inside and outside design temperatures re 23 °C and -5 °C, respectively. Calculate the followings: a- The unheated mean radiant temperature. b- Explore the possibility of using underfloor heating system to heat the room. C- Minimum floor area needed for the underfloor heating system. d- Water flow rate. e- pump head required for underfloor heating system. Make reasonable assumption concerning the number of pipe loops and pipe diameter.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Dimensional Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning