The larger impurities and cloudy sediments in the water of aquarium may be removed by means of filtering, as shown in the figure. For this reason, the water in the aquarium must be recirculated through the filter at a volumetric flow rate of 0.000462 m3/s. The water in the aquarium is forced through the filter by using the pressurized air from an aerotor pump. The cross-sectional areas of the glass tube and plastic tube are 0.000162 m2 and 0.0000262 m2 respectively. Assume that densities of water, air and air-water mixture are 996,2 kg/m3, 1.162 kg/m3 and 962 kg/m3 respectively. Atmospheric pressure is 106225 Pa. Neglecting all the losses, determine i-the pressure difference that must be created by the aerator pump ii-the volumetric flow rate of the air through the plastic tube iii- the power that must delivered by the aerator pump for overall efficiency %66,2. Solve the problem by making the necessary assumptions and drawing the schematic figure. (0.05ab=0.0562 m and 0.4ab =0.462 m on the figure)

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter7: Forced Convection Inside Tubes And Ducts
Section: Chapter Questions
Problem 7.43P: 7.43 Liquid sodium is to be heated from 500 K to 600 K by passing it at a flow rate of 5.0 kg/s...
icon
Related questions
Question

The larger impurities and cloudy sediments in the water of aquarium may be removed by means of filtering, as shown in the figure. For this reason, the water in the aquarium must be recirculated through the filter at a volumetric flow rate of 0.000462 m3/s. The water in the aquarium is forced through the filter by using the pressurized air from an aerotor pump. The cross-sectional areas of the glass tube and plastic tube are 0.000162 m2 and 0.0000262 m2 respectively. Assume that densities of water, air and air-water mixture are 996,2 kg/m3, 1.162 kg/m3 and 962 kg/m3 respectively. Atmospheric pressure is 106225 Pa. Neglecting all the losses, determine

i-the pressure difference that must be created by the aerator pump

ii-the volumetric flow rate of the air through the plastic tube

iii- the power that must delivered by the aerator pump for overall efficiency %66,2.

Solve the problem by making the necessary assumptions and drawing the schematic figure.

(0.05ab=0.0562 m and 0.4ab =0.462 m on the figure)

Expert Solution
steps

Step by step

Solved in 3 steps with 7 images

Blurred answer
Knowledge Booster
Convection
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning