VR Line impedance Mı M1 Transformer Vs VTt М M: M2 Line impedance neutral Line impedance M3 Figure 2: Distribution lines equivalent circuit. Figure 1: Low voltage lines exiting the distribution transformer center. In the given circuit, low voltage lines are seen coming out of a distribution transformer whose Low Voltage side is star connected. R (R = 0) phase for M1 line, S (@S = 120) phase for M2 line andT (øT = -120) phase is used for M3 line. The impedances of the loads at the end of the lines are (100 + j25) N and the impedances of the lines (1 + j) N. • Calculate the voltage occurring between the ends of M1, M2 and M3 loads as the voltages between Phase-Neutral at the distribution transformer output are 230V and the voltages between Phase-Phase are read as 230/3V.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.49P: Consider the single-Line diagram of a power system shown in Figure 3.42 with equipment ratings...
icon
Related questions
icon
Concept explainers
Question
Line impedance
Mi
M1
Transformer,
Vs
VT
M3,
M:
М2
Line impedance
neutral
Line impedance
M3
Figure 2: Distribution lines equivalent circuit.
Figure 1: Low voltage lines exiting the distribution
transformer center.
In the given circuit, low voltage lines are seen coming out of a distribution transformer
whose Low Voltage side is star connected. R (OR = 0) phase for M1 line, S (pS = 120)
phase for M2 line andT (oT = -120) phase is used for M3 line. The impedances of the
loads at the end of the lines are (100 + j25) N and the impedances of the lines (1 + j) N.
• Calculate the voltage occurring between the ends of M1, M2 and M3 loads as
the voltages between Phase-Neutral at the distribution transformer output are
230V and the voltages between Phase-Phase are read as 230/3V.
Transcribed Image Text:Line impedance Mi M1 Transformer, Vs VT M3, M: М2 Line impedance neutral Line impedance M3 Figure 2: Distribution lines equivalent circuit. Figure 1: Low voltage lines exiting the distribution transformer center. In the given circuit, low voltage lines are seen coming out of a distribution transformer whose Low Voltage side is star connected. R (OR = 0) phase for M1 line, S (pS = 120) phase for M2 line andT (oT = -120) phase is used for M3 line. The impedances of the loads at the end of the lines are (100 + j25) N and the impedances of the lines (1 + j) N. • Calculate the voltage occurring between the ends of M1, M2 and M3 loads as the voltages between Phase-Neutral at the distribution transformer output are 230V and the voltages between Phase-Phase are read as 230/3V.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning