Example 32.50. Resistances and Leakage reactance of 10 kVA, 50 Hz. 2300/230 V single phase distribution transformer are r, = 3.96 ohms, r, = 0.0396 ohms, x, = 15.8 ohms, x, = 0.158 ohm. Subscript I refers to HV and 2 to LV winding (a) transformer delivers rated kVA at 0.8 p.f. Lagging to a load on the LV. side. Find the H.V. side voltage necessary to maintain 230 V across Load- terminals. Also find percentage voltage regulation. (b) Find the power-factor of the rated load- current at which the voltage regulation will be zero, hence find the H.V. side voltage. %3D %3D (Nagpur University, November 1997) 10.000 020

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.65P: Reconsider Problem 3.64 with the change that now Tb includes both a transformer of the same turns...
icon
Related questions
icon
Concept explainers
Question
100%
Example 32.50. Resistances and Leakage reactance of 10 kVA, 50 Hz, 2300/230 V single phase
distribution transformer are r, = 3.96 ohms, r, = 0.0396 ohms, x, = 15.8 ohms, x, = 0.158 ohm.
Subscript I refers to HV and 2 to LV winding (a) transformer delivers rated kVA at 0.8 p.f. Lagging
to a load on the L.V. side. Find the H.V. side voltage necessary to maintain 230 V across Load-
terminals. Also find percentage voltage regulation. (b) Find the power-factor of the rated load-
current at which the voltage regulation will be zero, hence find the H.V. side voltage.
%3D
%3D
(Nagpur University, November 1997)
10.000 220
Transcribed Image Text:Example 32.50. Resistances and Leakage reactance of 10 kVA, 50 Hz, 2300/230 V single phase distribution transformer are r, = 3.96 ohms, r, = 0.0396 ohms, x, = 15.8 ohms, x, = 0.158 ohm. Subscript I refers to HV and 2 to LV winding (a) transformer delivers rated kVA at 0.8 p.f. Lagging to a load on the L.V. side. Find the H.V. side voltage necessary to maintain 230 V across Load- terminals. Also find percentage voltage regulation. (b) Find the power-factor of the rated load- current at which the voltage regulation will be zero, hence find the H.V. side voltage. %3D %3D (Nagpur University, November 1997) 10.000 220
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning