Which of the following would result in an incorrect value for the density of the acrylic slug using the method of neutral bouyancy.  Select all answers that would result in an incorrect value.     The student does not calibrate the syringe.     A student does not stir the solution before determining if the slug is suspended. They measure the density of the unstirred solution. After stirring, the slug rises to the top of the solution.     When measuring the density of the thiosulfate solution in which the acrylic slug is neutrally bouyant, the student accidentally drops some of the solution that is in the syringe before obtaining the mass of the solution in the syringe.     A student performs the experiment with the room at a higher temperature than room temperature. All of the reagents are at this higher temperature and the balance has been calibrated at this temperature.     Before performing the experiments, students from the previous section leave the bottle of thiosulfate open allowing a small amount of water to evaporate and slightly increase the concentration of thiosulfate. The students of the next section use this slightly concentration thiosulfate to determine the density of the slug.     During the calibration of the syringe, the student pulls the plunger farther back than the 1 mL mark each time that he collects pure water for the calibration.

Appl Of Ms Excel In Analytical Chemistry
2nd Edition
ISBN:9781285686691
Author:Crouch
Publisher:Crouch
Chapter4: Least-squares And Calibration Methods
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

Which of the following would result in an incorrect value for the density of the acrylic slug

using the method of neutral bouyancy.  Select all answers that would result in an incorrect value.

   

The student does not calibrate the syringe.

   

A student does not stir the solution before determining if the slug is suspended. They measure the density of the unstirred solution. After stirring, the slug rises to the top of the solution.

   

When measuring the density of the thiosulfate solution in which the acrylic slug is neutrally bouyant, the student accidentally drops some of the solution that is in the syringe before obtaining the mass of the solution in the syringe.

   

A student performs the experiment with the room at a higher temperature than room temperature. All of the reagents are at this higher temperature and the balance has been calibrated at this temperature.

   

Before performing the experiments, students from the previous section leave the bottle of thiosulfate open allowing a small amount of water to evaporate and slightly increase the concentration of thiosulfate. The students of the next section use this slightly concentration thiosulfate to determine the density of the slug.

   

During the calibration of the syringe, the student pulls the plunger farther back than the 1 mL mark each time that he collects pure water for the calibration.

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Solutions
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Chemistry: Matter and Change
Chemistry: Matter and Change
Chemistry
ISBN:
9780078746376
Author:
Dinah Zike, Laurel Dingrando, Nicholas Hainen, Cheryl Wistrom
Publisher:
Glencoe/McGraw-Hill School Pub Co