P1 10 Boiler 12. P13 8200 PIV 14 16 Closed Closed FWHI FWHII 8 T13 350 13 PIII High-P Turbine Open FWH PII of P14 5200 T[C] 17 Low-P Turbine 18 m P15 3000 PI рекрај - Reversible processes. There is no pressure drop in the boiler and pipes. The turbines are adiabatic (adiabatic + reversal = sentropic.) The inlet temperatures to the turbines are the same. At the entrance to each pump, the water is in a state of saturated liquid. In closed heat exchangers, the cooling water is at of the dis Condenser P16 290 P18 110

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter45: Domestic Refrigerators And Freezers
Section: Chapter Questions
Problem 20RQ: Welded ______sealed compressors are normally used in household refrigerators.
icon
Related questions
Question
100%
Plot the cycle points on a T-s diagram
C. Calculate the specific power of the turbines (each separately.)
d. Calculate the specific work of the pumps (each separately)
E. Calculate the amount of specific heat evacuated in the condenser.
Transcribed Image Text:Plot the cycle points on a T-s diagram C. Calculate the specific power of the turbines (each separately.) d. Calculate the specific work of the pumps (each separately) E. Calculate the amount of specific heat evacuated in the condenser.
P1
10
Boiler
12
10
P13
8200
Closed
FWHI
PIV
14
8
16
T13
350
13
Closed
FWH II
PIII
High-P
Turbine
Open
FWH
PII
10H
P14
5200
+[C]
17
Low-P
Turbine
18 m
P15
3000
PI
р[кра]
Reversible processes.
• There is no pressure drop in the boiler and pipes.
• The turbines are adiabatic (adiabatic + reversal =
isentropic.)
• The inlet temperatures to the turbines are the
same.
• At the entrance to each pump, the water is in a
state of saturated liquid.
• In closed heat exchangers, the cooling water is at
the saturation temperature of the discharge water
19
11
Condenser
P16
290
P18
110
Transcribed Image Text:P1 10 Boiler 12 10 P13 8200 Closed FWHI PIV 14 8 16 T13 350 13 Closed FWH II PIII High-P Turbine Open FWH PII 10H P14 5200 +[C] 17 Low-P Turbine 18 m P15 3000 PI р[кра] Reversible processes. • There is no pressure drop in the boiler and pipes. • The turbines are adiabatic (adiabatic + reversal = isentropic.) • The inlet temperatures to the turbines are the same. • At the entrance to each pump, the water is in a state of saturated liquid. • In closed heat exchangers, the cooling water is at the saturation temperature of the discharge water 19 11 Condenser P16 290 P18 110
Expert Solution
steps

Step by step

Solved in 6 steps with 6 images

Blurred answer
Follow-up Questions
Read through expert solutions to related follow-up questions below.
Follow-up Question

why does h[11] = h[10]= h[12], thank you so much

Solution
Bartleby Expert
SEE SOLUTION
Knowledge Booster
Refrigeration and Air Conditioning
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning