10 .Diversity factor reduces a) simultaneous maximum demand on station for same individual demands b) capital cost for the station c) overall rate for generation of electricity d) all of these 11. Load factor is defined as a) Maximum demand/average demand c) Maximum demand/Peak load b) Average demand/Maximum demand d) Maximum demand/Minimum load 12. In flat rate tariffs, the rate is fixed by taking into account the consumers d) a and b a) diversity factor c) plant use factor b) load factor 13. When the no

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter12: Power System Controls
Section: Chapter Questions
Problem 12.5P
icon
Related questions
Question
10 .Diversity factor reduces
a) simultaneous maximum demand on station for same individual demands b) capital cost for the station
c) overall rate for generation of electricity
11. Load factor is defined as
d) all of these
a) Maximum demand/average demand
c) Maximum demand/Peak load
b) Average demand/Maximum demand
12. In flat rate tariffs, the rate is fixed by taking into account the consumers
d) Maximum demand/Minimum load
a) diversity factor
b) load factor
c) plant use factor
d) a and b
13. When the power factor of a load increases, the losses in the transmission and distribution lines
a) Increase
b) Decrease
c) Remain same
d) Uncertain
14. The Advantages of D.C. transmission system over A.C. is
a) No skin effect
b) Charging currents are eliminated
c) Line regulation is improved d) All of these
15.For conventional power plants, running cost is minimum for
a) Thermal plant
b) Nuclear plant
c) Hydro plant
d) Diesel plant
16.The disadvantage of flat rate tariff is that it is difficult to
a) Arrive at a load factor and diversity factor to decide the tariff b) Estimate the cost of generation
c) Control the desired power factor
d) All of these
17. Which of the following hydraulic turbine is used for water heads exceeding 400 meters?
a) Kaplan turbine
18. Heavy water implies
a) H20
c) Francis turbine
d) None of these
b) Pelton wheel
d) D20
b) W20
c) B20
19. The main objective of tariff is to distribute equitably the cost of
a) Supplying energy amcng the various classification of users
c) Energy production among aii its consumers
b) Power transmission and distribution
d) Installation and fuel
20. Running cost of powe: plt is tased on the cost of
d) All of thes
c) Maintenance and operation
b; Consemable items
a) Energy or fuel
b) Operation, supplies, and maintenance of equipment
d) All of these
21.
All types of tariffs must recover the cost of
a) Capital investment in generating equipment
c) Metering equipment, billing, collection costs, profit and wages
3
Transcribed Image Text:10 .Diversity factor reduces a) simultaneous maximum demand on station for same individual demands b) capital cost for the station c) overall rate for generation of electricity 11. Load factor is defined as d) all of these a) Maximum demand/average demand c) Maximum demand/Peak load b) Average demand/Maximum demand 12. In flat rate tariffs, the rate is fixed by taking into account the consumers d) Maximum demand/Minimum load a) diversity factor b) load factor c) plant use factor d) a and b 13. When the power factor of a load increases, the losses in the transmission and distribution lines a) Increase b) Decrease c) Remain same d) Uncertain 14. The Advantages of D.C. transmission system over A.C. is a) No skin effect b) Charging currents are eliminated c) Line regulation is improved d) All of these 15.For conventional power plants, running cost is minimum for a) Thermal plant b) Nuclear plant c) Hydro plant d) Diesel plant 16.The disadvantage of flat rate tariff is that it is difficult to a) Arrive at a load factor and diversity factor to decide the tariff b) Estimate the cost of generation c) Control the desired power factor d) All of these 17. Which of the following hydraulic turbine is used for water heads exceeding 400 meters? a) Kaplan turbine 18. Heavy water implies a) H20 c) Francis turbine d) None of these b) Pelton wheel d) D20 b) W20 c) B20 19. The main objective of tariff is to distribute equitably the cost of a) Supplying energy amcng the various classification of users c) Energy production among aii its consumers b) Power transmission and distribution d) Installation and fuel 20. Running cost of powe: plt is tased on the cost of d) All of thes c) Maintenance and operation b; Consemable items a) Energy or fuel b) Operation, supplies, and maintenance of equipment d) All of these 21. All types of tariffs must recover the cost of a) Capital investment in generating equipment c) Metering equipment, billing, collection costs, profit and wages 3
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning